component
AP2162ASG-13
Public Made by Adomby adom
Diodes Incorporated AC-DC Controllers and Regulators, SO-8. Pinout extracted from the datasheet, KiCad symbol/footprint/3D.
← Commit history
page.json+11−8@@ -38,43 +38,43 @@ "number": "2", "name": "IN", "type": "power_in",- "description": "Voltage input pin, 2.7 V to 5.5 V operating range (6.5 V abs max). Feeds both internal high-side switches; bypass with 1 \u00b5F ceramic close to the pin."+ "description": "Voltage input pin, 2.7 V to 5.5 V operating range (6.5 V abs max). Feeds both internal high-side switches; bypass with 1 µF ceramic close to the pin." }, { "number": "3", "name": "EN1", "type": "input",- "description": "Switch 1 enable input. Active LOW on AP2162A (drive to GND to turn Channel 1 on; drive high to disable and engage output discharge). VIL \u2264 0.8 V, VIH \u2265 2 V. Do not float."+ "description": "Switch 1 enable input. Active LOW on AP2162A (drive to GND to turn Channel 1 on; drive high to disable and engage output discharge). VIL ≤ 0.8 V, VIH ≥ 2 V. Do not float." }, { "number": "4", "name": "EN2", "type": "input",- "description": "Switch 2 enable input. Active LOW on AP2162A (drive to GND to turn Channel 2 on; drive high to disable and engage output discharge). VIL \u2264 0.8 V, VIH \u2265 2 V. Do not float."+ "description": "Switch 2 enable input. Active LOW on AP2162A (drive to GND to turn Channel 2 on; drive high to disable and engage output discharge). VIL ≤ 0.8 V, VIH ≥ 2 V. Do not float." }, { "number": "5", "name": "FLG2", "type": "output",- "description": "Switch 2 overcurrent / overtemperature fault report. Open-drain, active LOW when a fault is triggered. Requires an external pull-up (typ 10 k\u03a9). Blanking time 7 ms typ suppresses false trips."+ "description": "Switch 2 overcurrent / overtemperature fault report. Open-drain, active LOW when a fault is triggered. Requires an external pull-up (typ 10 kΩ). Blanking time 7 ms typ suppresses false trips." }, { "number": "6", "name": "OUT2", "type": "power_out",- "description": "Channel 2 switched voltage output. Delivers up to 1.0 A recommended continuous load current (1.4 A typ current limit). Bypass with 1 \u00b5F plus 10 \u00b5F (120 \u00b5F per hub for USB 2.0)."+ "description": "Channel 2 switched voltage output. Delivers up to 1.0 A recommended continuous load current (1.4 A typ current limit). Bypass with 1 µF plus 10 µF (120 µF per hub for USB 2.0)." }, { "number": "7", "name": "OUT1", "type": "power_out",- "description": "Channel 1 switched voltage output. Delivers up to 1.0 A recommended continuous load current (1.4 A typ current limit). Bypass with 1 \u00b5F plus 10 \u00b5F (120 \u00b5F per hub for USB 2.0)."+ "description": "Channel 1 switched voltage output. Delivers up to 1.0 A recommended continuous load current (1.4 A typ current limit). Bypass with 1 µF plus 10 µF (120 µF per hub for USB 2.0)." }, { "number": "8", "name": "FLG1", "type": "output",- "description": "Switch 1 overcurrent / overtemperature fault report. Open-drain, active LOW when a fault is triggered. Requires an external pull-up (typ 10 k\u03a9). Blanking time 7 ms typ suppresses false trips."+ "description": "Switch 1 overcurrent / overtemperature fault report. Open-drain, active LOW when a fault is triggered. Requires an external pull-up (typ 10 kΩ). Blanking time 7 ms typ suppresses false trips." } ], "provenance": {@@ -164,5 +164,8 @@ "docs/ap2162asg-13-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }