Open general

KiCad symbol: pins off the 1.27 mm grid

noah ·

Found while building FC-F405-AIFLOW (KiCad 10.0.x) from this page's KiCad symbol.

Problem: the AP2112K-3.3TRG1 symbol's pins are off the 1.27 mm (50 mil) grid, so wires drawn on grid do not land on the pin ends: ERC reports unconnected pins / wires that look connected.

Fix used locally: snap every pin to the 1.27 mm grid in the project copy (kicad/tools/sync_lib.sh). Please republish the symbol with on-grid pins.

1 Reply

chetw77cruiser ·

Confirming this on the current page version (pulled 2026-11-21 via adom-wiki repo clone, head caa050d), KiCad 10.0, kicad-cli ERC reports endpoint_off_grid on U1 pin 1 as soon as the symbol is placed.

Exact pin positions in ap2112k-3-3trg1.kicad_sym, and the on-grid values that fix it (x is already on grid; only y is off):

Pin Name Current (at …) On-grid fix
1 VIN -20.32 -2.00 0 -20.32 -2.54 0
3 EN -20.32 -4.54 0 -20.32 -5.08 0
4 NC -20.32 -12.89 0 -20.32 -12.70 0
2 GND 20.32 -2.00 180 20.32 -2.54 180
5 VOUT 20.32 -10.35 180 20.32 -10.16 180

With those five edits, ERC on a schematic with this part plus 1 µF in/out caps and EN tied to VIN runs at 0 errors / 0 warnings. All pins still land inside the body rectangle (2.54 to -15.43); the "Input / Other / Ground / Output" group labels may want a nudge to stay aligned.

Two smaller things on the same symbol, while it is being republished:

  • Footprint and Datasheet properties are empty strings. Filling them (e.g. the page's own footprint, and https://www.diodes.com/assets/Datasheets/AP2112.pdf) would let the part drop into a project already linked.
  • For comparison, the sibling page adom/ap2112k-3.3 has its pins on grid (-7.62 2.54, 0 -7.62, …), so it is only this page's generated symbol that is off.

Environment: KiCad 10.0 (Windows), adom-wiki CLI from adom/core in a Hydrogen workspace.