← Commit history

afc10-s02pca-00: factory component page (tier=lcsc)

Ray ·8586e36a97 ·5d ago ·parent 4428a9e
1 file changed +283−29
page.json+283−29
@@ -1,8 +1,11 @@ {+  "schema_version": 1,+  "type": "component",   "slug": "afc10-s02pca-00",+  "title": "AFC10-S02PCA-00",+  "brief": "JUSHUO Wire To Board Connector, SMD,P=1mm. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "version": "0.1.0",-  "type": "component",-  "description": "JUSHUO Wire To Board Connector, SMD,P=1mm. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "license": "CC-BY-SA-4.0",   "tags": [     "component",     "connectors",@@ -10,26 +13,6 @@     "factory-2.0.0",     "extractor-text"   ],-  "dependencies": {},-  "hero": {-    "type": "image",-    "path": "docs/hero.png"-  },-  "files": [-    "page.json",-    "README.md",-    "afc10-s02pca-00.kicad_sym",-    "afc10-s02pca-00.kicad_mod",-    "afc10-s02pca-00.glb",-    "afc10-s02pca-00.step",-    "afc10-s02pca-00.lbr",-    "docs/hero.png",-    "docs/afc10-s02pca-00-datasheet.pdf",-    "viewers/symbol.html",-    "viewers/footprint.html",-    "afc10-s02pca-00-hero.glb",-    "afc10-s02pca-00-hero.overlay.json"-  ],   "component": {     "mpn": "AFC10-S02PCA-00",     "manufacturer": "JUSHUO",@@ -120,12 +103,12 @@         "origin": "footprint origin = pad-pattern centre",         "seat": "z = 0",         "extents_mm": [-          4,+          4.0,           3.6,           4.32         ],-        "zmin_mm": 0,-        "centre_offset_mm": 0,+        "zmin_mm": 0.0,+        "centre_offset_mm": 0.0,         "footprint_binding": "identity",         "sha256": "df87a44803f392435a972f8b8837b8c2700842cc58412c1a4338fcdcf449fc3d",         "checked": "2026-11-06",@@ -133,10 +116,281 @@       }     ]   },-  "visibility": "public",-  "org": "adom",+  "metadata": {+    "specs": {+      "Manufacturer": "JUSHUO",+      "Package": "JST_SH_BM02B-SRSS-TB_1x02-1MP_P1.00mm_Vertical",+      "Category": "Connectors",+      "Pins": "2"+    },+    "appearance": {+      "housing": {+        "quote": "基座 base 1.0 LCP E130i",+        "page": 4,+        "doc": "ds.pdf",+        "material": "LCP"+      },+      "version": 1,+      "datasheet_sha256": ""+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "",+      "rows": [+        {+          "name": "Rated voltage",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 50,+          "conditions": "Standard rating (The rated voltage)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Rated current",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "AC/DC",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature range",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -25,+          "typ": null,+          "max": 105,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating humidity range",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "%",+          "min": null,+          "typ": null,+          "max": 90,+          "conditions": "Relative humidity, as printed 'below 90%'",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -20,+          "typ": null,+          "max": 50,+          "conditions": "Packed connector; relative humidity not more than 90%; no acid, alkaline or corrosive gases",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Transport ambient temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -20,+          "typ": null,+          "max": 50,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Contact resistance (initial)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "Mated connector, contact resistance meter, closed loop between two terminals",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Insulation resistance (initial)",+          "symbol": "",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 100,+          "typ": null,+          "max": null,+          "conditions": "500 V DC applied for 1 minute between adjacent contacts and between contacts and enclosure",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Insulation resistance (after moisture resistance test)",+          "symbol": "",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 50,+          "typ": null,+          "max": null,+          "conditions": "40°C ±2°C, 90-96% RH, 96 H",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Withstand voltage (after moisture resistance test)",+          "symbol": "",+          "kind": "electrical",+          "unit": "VAC/min",+          "min": 200,+          "typ": null,+          "max": null,+          "conditions": "40°C ±2°C, 90-96% RH, 96 H; printed as 200VAC/min",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Contact resistance (after heating test)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "After +105°C ±2°C for 96 H, recovered 1-2 H",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Contact resistance (after cold test)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "After -25°C ±2°C for 96 H, recovered 1-2 H",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Contact resistance (after temperature cycle)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "After 5 cycles of -25°C ±3°C / +105°C ±3°C, recovered 2 H",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Contact resistance (after salt spray)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "After continuous 5±1% NaCl spray for 24 H",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Tin coverage of solder area (weldability)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": 95,+          "typ": null,+          "max": null,+          "conditions": "Dipped in 235±5°C tin solution for 2.5±0.5 s",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Contact resistance (after mechanical life)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "After 50 insertion/extraction cycles, unpowered, 10 times/min",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Pin fixing force (single pin)",+          "symbol": "",+          "kind": "electrical",+          "unit": "N",+          "min": 7,+          "typ": null,+          "max": null,+          "conditions": "Pull-out force of pin from pin holder, 25±3 mm/min",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Terminal retention in plastic part (single terminal)",+          "symbol": "",+          "kind": "electrical",+          "unit": "N",+          "min": 5,+          "typ": null,+          "max": null,+          "conditions": "Pull-out force of terminal from housing, 25±3 mm/min",+          "source_page": 8,+          "source": "datasheet"+        }+      ]+    }+  },+  "variants": [],+  "sections": [+    "hero",+    "viewers",+    "readme",+    "breadcrumbs",+    "info"+  ],+  "discovery_triggers": [+    "afc10-s02pca-00"+  ],+  "discovery_pitch": "AFC10-S02PCA-00 (JUSHUO) component page: datasheet pinout, KiCad symbol, footprint and 3D.",   "author": {     "name": "Ray",     "email": "[email protected]"-  }-}\ No newline at end of file+  },+  "dependencies": {},+  "hero": {+    "type": "image",+    "path": "docs/hero.png"+  },+  "files": [+    "page.json",+    "README.md",+    "afc10-s02pca-00.kicad_sym",+    "afc10-s02pca-00.kicad_mod",+    "afc10-s02pca-00.glb",+    "afc10-s02pca-00.step",+    "afc10-s02pca-00.lbr",+    "docs/hero.png",+    "docs/afc10-s02pca-00-datasheet.pdf",+    "viewers/symbol.html",+    "viewers/footprint.html",+    "afc10-s02pca-00-hero.glb",+    "afc10-s02pca-00-hero.overlay.json"+  ]+}