# Assumption-based Q1 cooling review

This is a prototype sensitivity calculation, not a resolved 3D fin-temperature analysis or thermal qualification. The command cap remains 5 W. The conservative screening source is 5.5 W at 40 °C ambient; the original junction-rise budget remains 15 °C.

The complete series path is Q1 junction → case (0.42 K/W) → electrical insulation and its two contacts → heatsink → ambient. The maximum total resistance at the screening point is 15/5.5 = **2.727 K/W**. After Q1's junction-to-case resistance, the interface and sink together must be at or below **2.307 K/W**.

| Assumed total interface | Maximum sink-to-air resistance to meet screening budget |
|---|---|
| 0.30 K/W | 2.007 K/W |
| 0.70 K/W | 1.607 K/W |
| 1.20 K/W | 1.107 K/W |
| 2.00 K/W | 0.307 K/W |

The nominal 0.70 K/W interface plus 1.20 K/W forced-air sink predicts a 12.76 °C junction rise (52.76 °C junction; 50.45 °C case). Replacing the sink assumption with 8 K/W for fan-off predicts a 50.16 °C junction rise (90.16 °C junction; 87.85 °C case). These are steady-state network predictions. The controller must disable load after fan failure; the fan-off result is retained as a failing case, not an allowed operating condition.

The 0.635 mm AlN wafer's calculated bulk resistance is only 0.0267 K/W at assumed 170 W/m·K and 140 mm² area. That does **not** establish the assembled interface resistance: contact films, flatness, hole area, pressure and spreading remain unknown. Do not replace the interface sweep with the bulk value. Supplier pad alternatives already examined have materially higher published resistance and must not inherit the nominal 0.70 K/W assumption.

The 21 ms hypothetical fault reaction adds 0.1155 J at 5.5 W. Without package transient impedance, thermal mass and sensor response, that energy cannot be converted into a trustworthy temperature rise. A case sensor also lags the junction. Neither a 55 °C case trip nor this energy calculation proves junction protection.

## Prototype decision

Proceed with the commercial-sink envelope, assumed AlN isolation, duct and side fan for fit and assembly review. Keep the output locked in the built firmware. Do not advertise increased wattage from the sweep's hypothetical power column. Probe replay and board-solid clearance checks do not validate airflow, clamping pressure, electrical isolation or cooling.

Before enabling load on hardware: verify isolation and assembly fit, measure fan PWM/tach behavior, instrument Q1 case and sink, ramp power under independent protection, characterize installed interface/sink resistance, and exercise fan-stall shutdown. Qualification remains open until those measurements support the original limits.

Source artifacts: `thermal-assumptions.json`, `thermal-sensitivity.csv`, `thermal-sensitivity.png`. This report addresses Q1's external thermal path; it does not replace D1/PCB thermal review.