# Installed airflow: pressure budget, not acceptance

The 50 x 50 x 25 mm ATS cooler has not passed the assembly thermal gate. The Sunon fan's 8.9 CFM free-air rating is measured at zero static pressure; it cannot be applied directly to this installation. The reference fan curve, a system pressure-loss curve, leakage and inlet/outlet conditions must meet at the installed operating point.

`pressure-budget.json` and `tools/screen_side_fan_airflow.py` retain the exact PDF hashes and a visibly digitized, approximate fan curve from Sunon D04114960G-01, page 5. The calculation uses a provisional 50 x 25 mm gross approach area, fan similarity laws, and a density correction from 25 to 40 C. These are planning assumptions, not guaranteed limits or a CFD solution.

| Reference velocity | Gross flow | Available pressure at 5000 RPM | At 5950 RPM | At 7000 RPM |
|---|---:|---:|---:|---:|
| 1.0 m/s | 2.65 CFM | 10.8 Pa | 17.8 Pa | 28.1 Pa |
| 1.5 m/s | 3.97 CFM | 9.6 Pa | 13.8 Pa | 19.6 Pa |

These pressure budgets must cover the complete heatsink, guard, duct and entry/exit losses. No system-loss data have yet established that they do. At the unchanged 5.5 W guard case and 40 C ambient, the conditional temperature rises using ATS reference resistances are 13.71 C for ducted 1.0 m/s and 12.61 C for ducted 1.5 m/s. The existing 15 C rise ceiling remains. These numbers are conditional catalog calculations; they do not grant thermal credit, validate small-source spreading or replace the still-air/fault review.

The current assembly has no sealed duct, so ducted catalog values must not be entered into the accepted specification. An airflow path must also preserve the probe bank and tether clearance. RPM feedback detects some fan failures; it cannot detect every blocked-airflow condition. Temperature sensing and shutdown lag require later prototype measurements.

The manufacturer drawing on page 6 recommends M4 machine screws at 3-4 kgf-cm. R9 corrects the earlier M3 fan mounting to nominal M4 × 35 bolts with matching plate clearances, washers and nuts. Exact orderable hardware and torque/locking process remain open. The Q1 insulating M3 fastener is a separate item.

Sources: [ATS reference thermal data](https://www.qats.com/DataSheet/ATS-CPX050050025-124-C1-R0), local Sunon manufacturer performance PDF at `mechanical/vendor/MF40200V1-performance.pdf`, and [ebm-papst fan similarity laws](https://www.ebmpapst.com/us/en/support/faq.html). Exact fin geometry or supplier pressure-drop data, a sealed-duct model, installed airflow, interface pressure/resistance and fault transients remain open.