analyze current (adom-aiflow 0.2.24): SHUNT_P needs copper to Q1.3; LOAD_POS needs U4.8 declared as a 0 A sense terminal
What changed
adom-aiflow 0.2.24 closed a loophole in analyze current (adom/adom-aiflow#107). Before, any pour on a loaded net counted as "carrying the load", even one nowhere near the narrow pieces. Now a pour counts only when it covers each track that fails at full load, or reaches every current-carrying terminal of the net.
Checked against this board's saved runs, two nets that passed before now fail. Nothing here is urgent if the current revision is already built: it matters the next time this board goes through analyze current or finish.
1. SHUNT_P: real copper fix needed
- What fails: 3 A runs on a 1.2 mm track into Q1.3 (the MOSFET source). That's about 12 °C rise against the spec's 10 °C limit.
- Why it passed before: a SHUNT_P pour elsewhere on the net counted, although it doesn't reach Q1.3.
- Fix, best first:
- Extend the SHUNT_P pour to cover the track into Q1.3 (or reach the pin). This is the shunt's high-current path, so copper is the right answer.
- Or widen that track to about 1.5 mm or more, so it lands under 10 °C at 3 A.
- Only if a 12 to 15 °C rise really is acceptable there, set a per-net
maxRiseCwith the reason written beside it. Never relax it just to pass.
2. LOAD_POS: spec correction only
- What fails: U4.8, the INA226 sense input, is counted as a current-carrying terminal of LOAD_POS, so the pour has to reach it.
- Fix: declare it at 0 A in
spec.loads.LOAD_POS.terminals. It's a sense pin, so this is the honest description, and no board change is needed. A fresh same-input Fields solve would also settle it.
Afterwards
Land the copper change, refill, save, adopt, then run analyze current (and adom-fields analyze if the solve is stale). Both nets should pass. If either still fails, please post the analyze output here.
Upgrade first: tell your AI "give me the latest adom-aiflow"; adom-aiflow --version should say 0.2.24 or later.