← Commit history
docs/runs/board-codex-20261007-1749/README.md+28−8
@@ -1,6 +1,6 @@ # AI Flow run: codex on board-0 -**Running**: step `placement`, 1570.1 min of AI time since the prompt (6205.5 min on the wall clock). This page updates at every step change.+**Running**: step `routing`, 1571.3 min of AI time since the prompt (6206.8 min on the wall clock). This page updates at every step change.  Prompt at 2026-10-07T17:49:14Z (UTC). Flow: board. Every number here is from the run's append-only ledger (run.jsonl). AI time is the time the AI was working on a prompt: from the human's prompt to the AI's done, with any gap over 15 min where no command ran (unobserved, not proven idle) cut out. @@ -22,8 +22,8 @@ One row per human prompt: the AI's time on it, unobserved gaps excluded by the h | 10 | 2026-10-09T18:12:40Z | (open) | 10.1 | 99 | Resume electronic-load completion: inspect native board, land reviewed diode thermal vias  | | 11 | 2026-10-09T20:02:16Z | (open) | 220.9 | 861 | Continue board 18 to completion; resolve package-mounted cooling and thermal solver suppor | | 12 | 2026-10-10T14:04:14Z | (open) | 202.2 | 312 | Continue electronic-load engineering and recorded workflow; magnetic-field question withdr |-| 13 | 2026-10-10T22:38:10Z | (open) | 641.1 | 956 | Continue to the finish line; resolve supported cooling design and remaining deliverables,  |-| **all** | | | **1570.1** | | |+| 13 | 2026-10-10T22:38:10Z | (open) | 642.3 | 956 | Continue to the finish line; resolve supported cooling design and remaining deliverables,  |+| **all** | | | **1571.3** | | |  ## Per step @@ -32,8 +32,8 @@ AI time only, the idle cut out. | Step | AI min | AI thinking min | Tool min | Turns | Visits | Returns | Longest think | |---|---|---|---|---|---|---|---| | intake | 2.6 | 0.3 | 2.2 | 3 | 1 | 0 | 0.3 min |-| placement | 9.0 | 0.0 | 9.0 | 29 | 5 | 3 | 0.0 min |-| routing | 59.2 | 0.0 | 59.2 | 67 | 5 | 1 | 0.0 min |+| placement | 9.5 | 0.0 | 9.5 | 31 | 5 | 3 | 0.0 min |+| routing | 59.2 | 0.0 | 59.2 | 68 | 6 | 1 | 0.0 min | | pours | 4.7 | 0.0 | 4.7 | 16 | 1 | 0 | 0.0 min | | current | 77.8 | 0.0 | 77.8 | 120 | 1 | 0 | 0.0 min | | thermal | 54.8 | 0.0 | 54.8 | 258 | 1 | 0 | 0.0 min |@@ -42,10 +42,10 @@ AI time only, the idle cut out. | libraries | 3.8 | 0.0 | 3.8 | 18 | 2 | 0 | 0.0 min | | models | 15.3 | 0.0 | 15.3 | 30 | 2 | 0 | 0.0 min | | outline | 0.1 | 0.0 | 0.1 | 2 | 1 | 0 | 0.0 min |-| rules | 1246.4 | 0.0 | 1246.4 | 14 | 1 | 0 | 0.0 min |+| rules | 1247.1 | 0.0 | 1247.1 | 14 | 1 | 0 | 0.0 min | | test-plan | 0.7 | 0.0 | 0.7 | 10 | 2 | 0 | 0.0 min | | thermal-vias | 26.9 | 0.0 | 26.9 | 177 | 4 | 0 | 0.0 min |-| **total** | **1570.1** | **0.3** | **1569.8** | | | | |+| **total** | **1571.3** | **0.3** | **1571.0** | | | | |  ## Returns to earlier steps @@ -171,6 +171,8 @@ AI time only, the idle cut out. - 2026-10-12T01:09:00Z net FAN_TACH: 74 items highlighted - 2026-10-12T01:09:18Z capture-stop - 2026-10-12T01:14:46Z clip-start:placement-5+- 2026-10-12T01:15:29Z capture-stop+- 2026-10-12T01:15:58Z clip-start:routing-6  ## Where the board stands @@ -667,12 +669,30 @@ What this step does: place the parts for routability, current and heat; the bina  Why the AI came back here: Verify adopted Board32 poses and native placement constraints without replaying moves -**Clip: placement, visit 5, still recording (started 2026-10-12T01:14:46Z); it appears here when the step ends.**+**Clip: placement, visit 5, the PCB editor from 2026-10-12T01:14:46Z to 2026-10-12T01:15:29Z. Motion only: 0.7 min of real time, 0 s of it had something moving; the clock in the corner is the real elapsed time.**++<video width="100%" controls><source src="/blob/app/adom-custom-electronic-load/docs/runs/board-codex-20261007-1749/placement-5.mp4" type="video/mp4"></video>++**Contact sheet: nine frames spread through the placement, visit 5 clip, what the camera saw.**++![nine frames of placement, visit 5](/blob/app/adom-custom-electronic-load/docs/runs/board-codex-20261007-1749/placement-5-sheet.png)  **Screenshot: the board when placement, visit 5 began.**  ![the board when placement, visit 5 began](/blob/app/adom-custom-electronic-load/docs/runs/board-codex-20261007-1749/shot-placement-5-start.png) +### routing, visit 6++What this step does: route to 100 percent with the spec's rules, gate with KiCad's DRC, land as undo steps; the AI takes it with take route=ai++Why the AI came back here: Adopted Board32 copper is already routed; verify existing routing and retain it++**Clip: routing, visit 6, still recording (started 2026-10-12T01:15:58Z); it appears here when the step ends.**++**Screenshot: the board when routing, visit 6 began.**++![the board when routing, visit 6 began](/blob/app/adom-custom-electronic-load/docs/runs/board-codex-20261007-1749/shot-routing-6-start.png)+ ## Plan usage, the second cost line  Percent of each plan limit used, as the provider reports it, at the start of the run and at its end.
docs/runs/board-codex-20261007-1749/placement-5-sheet.pngadded
⋯ 1 unchanged line ⋯
docs/runs/board-codex-20261007-1749/placement-5.mp4added
⋯ 1 unchanged line ⋯
docs/runs/board-codex-20261007-1749/shot-routing-6-start.pngadded
⋯ 1 unchanged line ⋯