Record finer-grid current failure and preserve unaccepted source-taper experiment

John Lauer ·bcfbe47aef · ·parent 9ad84f1
3 files changed +42−1
docs/issue-repairs-20261028/README.md+1−1
@@ -6,7 +6,7 @@ Work in progress. No fabrication or purchase approval.  Native KiCad 10.0.3 on arav-rog preserved the original 1.2 mm SHUNT_P traces and extended the source pour toward Q1.3. The first 1.5 mm trace candidate was rejected for Kelvin-pad/gate clearances. Latest adopted candidate is AIFlow board-17, including a DRC-clean 0.6/0.3 mm source via at (134.8,86.0) mm. A continuous B.Cu source region reaches both Q1.3 and RSH1.1, with 0.25 mm local clearance; the absorbed empty zone was removed. Native DRC: zero errors and zero opens; warnings remain. Service DRC did not reproduce desktop sidecar-rule handling and is not used as acceptance evidence. -LOAD_POS U4.8 is declared sense-only (0 A) in the conductor-capacity screen. Its original nominal 28.916 uA bias remains in the saved pre-change spec and notes. AIFlow records the amendment; 3 A load and 10 C rise limits are unchanged. LOAD_POS passes. All six loaded nets now pass the conservative copper screen. A fresh 0.2 mm Fields solve completed on board-16 and reports a roughly 61 A/mm² SHUNT_P hotspot against 60 A/mm², 11.9 mV ground offset against 10 mV, and thermal failures in the PCB-only model. Board-16 watched solve reproduced the hotspot. The board-17 0.2 mm watched solve completed: SHUNT_P still fails at 60.4 A/mm². A 0.1 mm full-spec watched solve is in progress to check grid convergence. An extra via at (124.9,83.4) mm was rejected after its diagnostic-only solve worsened the hotspot to 71 A/mm²; that candidate was not adopted. The board is not qualified; full assembled thermal modeling is still required. The earlier board-13 solve was terminated as obsolete; no result from it is used. Do not claim this issue resolved yet.+LOAD_POS U4.8 is declared sense-only (0 A) in the conductor-capacity screen. Its original nominal 28.916 uA bias remains in the saved pre-change spec and notes. AIFlow records the amendment; 3 A load and 10 C rise limits are unchanged. LOAD_POS passes. All six loaded nets now pass the conservative copper screen. A fresh 0.2 mm Fields solve completed on board-16 and reports a roughly 61 A/mm² SHUNT_P hotspot against 60 A/mm², 11.9 mV ground offset against 10 mV, and thermal failures in the PCB-only model. Board-16 watched solve reproduced the hotspot. The board-17 0.2 mm watched solve completed: SHUNT_P still fails at 60.4 A/mm². The 0.1 mm full-spec watched solve completed and still fails: SHUNT_P 74.1 A/mm² at (126.45,82.75) B.Cu. No peak acknowledgement was used. A source-taper candidate removes one redundant source stub and reshapes the source pour; native DRC with the complete project context passes 0 errors, 0 warnings, 0 opens, but the candidate is not yet adopted and diagnostic current analysis is pending. An extra via at (124.9,83.4) mm was rejected after its diagnostic-only solve worsened the hotspot to 71 A/mm²; that candidate was not adopted. The board is not qualified; full assembled thermal modeling is still required. The earlier board-13 solve was terminated as obsolete; no result from it is used. Do not claim this issue resolved yet.  ## JLCPCB #2 
revisions/compact-r11/issue-1-copper/current-board17-fine.txtadded+12
@@ -0,0 +1,12 @@+ERROR: current analysis not passed:+5V_AUX pass: the narrowest listed track carries the full specified load within 10 C+DUT_FUSED pass: branch currents give 5.34 C maximum track estimate against 10.00 C; barrel density 0.00 against 60.00 A/mm2; all through-terminal layer extremes checked+DUT_POS pass: branch currents give 3.96 C maximum track estimate against 10.00 C; barrel density 47.45 against 60.00 A/mm2; all through-terminal layer extremes checked+GND pass: pour on B.Cu+F.Cu (5789 mm2 filled) carries the load; tracks are 1.50 mm at most; the GND pour covers every piece too narrow for 3.0 A on its own layer (66 pieces)+LOAD_POS pass: pour on B.Cu+F.Cu (389 mm2 filled) carries the load; tracks are 1.75 mm at most; one B.Cu+F.Cu pour reaches all 2 LOAD_POS terminals, so the narrow tracks run beside it+SHUNT_P pass: pour on B.Cu+F.Cu (39 mm2 filled) carries the load; tracks are 2.30 mm at most; one B.Cu+F.Cu pour reaches all 2 SHUNT_P terminals, so the narrow tracks run beside it+(field screen: Fields SHUNT_P peak current density exceeds the 60 A/mm2 screen (74.1 A/mm2 at (126.45, 82.75) on B.Cu; a reviewed part-limited peak takes `analyze current --ack [email protected] --why ...`))+Hint: Fix what the failing lines say (pours, vias, widths, or placement), land it, measure again, then analyze again.+Hint: Now do the analysis yourself, not only this table: draw the current density on the copper (amps per square millimetre on every loaded net's pours and tracks; a Laplace solve on the filled copper between the source pads and the sink pads is enough, the board file has the filled polygons) as a 1920x1080 PNG with a colour scale, then `artifact --kind analysis-image --file <png> --caption "..."`. It becomes a fullscreen shot in the final video and a figure on the run page.+Hint: Then walk the pours this analysis judged on camera, under this same step: `tour nets --nets GND,LOAD_POS,SHUNT_P` (each net lit as a whole, pours and traces together, framed).+Hint: Input of `analyze current` (skill aiflow-power-layout): read /home/adom/.claude/skills/aiflow-power-layout/SKILL.md or /home/adom/project/adom_modules/adom/adom-aiflow/skills/aiflow-power-layout/SKILL.md, section "Input schemas"; also /home/adom/project/adom_modules/adom/adom-aiflow/docs/plan-schema.md.
revisions/compact-r11/issue-1-copper/source-taper-repair.pyadded+29
@@ -0,0 +1,29 @@+"""Native KiCad 10 candidate from board-17. Copy matching project sidecars FIRST.+Run on the desktop with KiCad Python; does not grant acceptance.+"""+from pathlib import Path+import pcbnew,json,shutil+p=Path(__file__).parent+source=p/'via-qualified.kicad_pcb';target=p/'source-taper.kicad_pcb'+for ext in ['kicad_pro','kicad_dru']:+ shutil.copyfile(source.with_suffix('.'+ext),target.with_suffix('.'+ext))+m=pcbnew.GetSettingsManager();project=str(target.with_suffix('.kicad_pro'))+assert m.LoadProject(project)+b=pcbnew.LoadBoard(str(source));b.SetProject(m.GetProject(project))+points=[(123.7,80.8),(125.9,80.8),(125.9,83.2),(126.4,83.4),(133.8,83.4),(135.4,84.7),(138,84.7),(138,88),(134.5,88),(133.5,85.2),(126,85.2),(123.7,83.6)]+zones=list(b.Zones());changed=[]+for z in zones:+ if z.m_Uuid.AsString()=='e0cd80c3-561d-4fab-b292-e46839ad4bed':+  z.Outline().RemoveAllContours();z.Outline().NewOutline()+  for x,y in points:z.Outline().Append(pcbnew.FromMM(x),pcbnew.FromMM(y))+  changed.append(z.m_Uuid.AsString())+tracks=list(b.GetTracks());removed=[]+for t in tracks:+ if t.m_Uuid.AsString()=='3b6462fa-fe3c-450b-b89f-ad9d10469424':+  removed.append(t.m_Uuid.AsString());b.Remove(t)+assert len(changed)==1 and len(removed)==1+pcbnew.SaveBoard(str(target),b)+# Re-read after removing a SWIG item before traversing zone wrappers.+b2=pcbnew.LoadBoard(str(target));b2.SetProject(m.GetProject(project))+pcbnew.ZONE_FILLER(b2).Fill(b2.Zones());pcbnew.SaveBoard(str(target),b2)+print(json.dumps({'changedZones':changed,'removedTracks':removed,'candidate':str(target),'acceptance':'Native DRC plus full-spec Fields required; diagnostic-only solves cannot qualify this candidate.'}))