← Commit history
Record verified software releases and remaining board acceptance failures
1 file changed
+26−16
docs/issue-repairs-20261028/README.md+26−16@@ -1,34 +1,44 @@ # Wiki issue repairs — 28 October 2026 -Work in progress. No fabrication or purchase approval.+Work remains in progress. No fabrication, purchase or physical qualification is implied. -## Electronic-load #1+| Item | Verified progress | Remaining work |+|---|---|---|+| JLCPCB #2 | Shared clearance generator and 2/4/6-layer profiles now cover all copper. Native 0.09 mm pad-gap fixture fails the 0.10 mm rule as intended. Issue closed. | Broader 3rdPartyFab profile work is separate. |+| Electronic-load #1 | Adopted board-18 passes native KiCad DRC: zero errors, warnings and opens, with exact project rules and restored libraries. All six conservative copper screens pass. | Full-spec 0.1 mm current solve still fails SHUNT_P: 72.7733 A/mm² against 60. Further candidates are diagnostic only. |+| AIFlow #60 | AIFlow 0.2.26 published, downloadable and installed. Geometry reports bind to the active board, request, report and STEP hashes; stale inputs are rejected. 496 workspace tests pass, nine existing tests ignored. | Actual board assembly review, wiring findings, standalone Mechanical/Wiring page releases. |+| PCBWay page | Public MIT app 0.1.1, source, approved hero, Linux release, installed binary and discovery verified. Real page inspected in Pup on arav-rog. | No new vendor quote or purchase was submitted during these repairs. | -Native KiCad 10.0.3 on arav-rog preserved the original 1.2 mm SHUNT_P traces and extended the source pour toward Q1.3. The first 1.5 mm trace candidate was rejected for Kelvin-pad/gate clearances. Latest adopted candidate is AIFlow board-17, including a DRC-clean 0.6/0.3 mm source via at (134.8,86.0) mm. A continuous B.Cu source region reaches both Q1.3 and RSH1.1, with 0.25 mm local clearance; the absorbed empty zone was removed. Native DRC: zero errors and zero opens; warnings remain. Service DRC did not reproduce desktop sidecar-rule handling and is not used as acceptance evidence.+## Board evidence -LOAD_POS U4.8 is declared sense-only (0 A) in the conductor-capacity screen. Its original nominal 28.916 uA bias remains in the saved pre-change spec and notes. AIFlow records the amendment; 3 A load and 10 C rise limits are unchanged. LOAD_POS passes. All six loaded nets now pass the conservative copper screen. A fresh 0.2 mm Fields solve completed on board-16 and reports a roughly 61 A/mm² SHUNT_P hotspot against 60 A/mm², 11.9 mV ground offset against 10 mV, and thermal failures in the PCB-only model. Board-16 watched solve reproduced the hotspot. The board-17 0.2 mm watched solve completed: SHUNT_P still fails at 60.4 A/mm². The 0.1 mm full-spec watched solve completed and still fails: SHUNT_P 74.1 A/mm² at (126.45,82.75) B.Cu. No peak acknowledgement was used. A source-taper candidate removes one redundant source stub and reshapes the source pour; native DRC with the complete project context passes 0 errors, 0 warnings, 0 opens, but the candidate is not yet adopted and diagnostic current analysis is pending. An extra via at (124.9,83.4) mm was rejected after its diagnostic-only solve worsened the hotspot to 71 A/mm²; that candidate was not adopted. The board is not qualified; full assembled thermal modeling is still required. The earlier board-13 solve was terminated as obsolete; no result from it is used. Do not claim this issue resolved yet.+The active run is `aiflow/compact-r11`, board-18. Its native verification uses the matching `.kicad_pro`, `.kicad_dru`, footprint table and libraries. Earlier warning reports from incomplete validation context are superseded, not waived. The three missing library footprints were recovered from the prior project revision. -## JLCPCB #2+LOAD_POS U4.8 is represented as a sense terminal (0 A) for the conductor-capacity screen; its original nominal 28.916 µA input bias remains recorded in the saved spec and amendment notes. The 3 A design load, 60 A/mm² current limit and 10°C copper-rise budget are unchanged. No peak acknowledgment or acceptance waiver has been used. -Candidate shared rule generator and 2/4/6-layer JLC profiles remove the track-only clearance condition. Native two-pad B.Cu regression fixture correctly rejects a 0.09 mm gap under the 0.10 mm rule. Working source: /home/adom/project/pcb-design-rules-issue-repair. Published and read back generator/profiles/evidence at e15d2c4f0847b3850e7ca95983247afd67def605. JLCPCB issue #2 is closed. Its rules command retrieves profiles live; no binary update is needed for the profile correction. Source skill guidance published at 0521d27a8756b10197e6b94fc1eee3c6ebfafa34; installed skill release is separate.+Board-18 uses a 2.4 × 3 mm oval Q1 source pad and a rerouted bottom drain approach. The full watched fine-grid solve still fails. A rounded-rectangle source-pad candidate is native-DRC clean but its tapered-source diagnostic fails at 82.48 A/mm². A wider-exit rounded candidate is undergoing a 0.1 mm diagnostic. Neither rounded candidate is adopted or fabrication-ready. -## AIFlow #60+PCB-only thermal results omit the assembled cooling path and must not be represented as the heatsink-cooled Q1 temperature or hardware qualification. Full assembled thermal evidence remains required. -Mechanical and wiring package manifests/installers prepared, release binaries built and installed locally. Five existing mechanical/wiring Rust unit tests and five PCBWay tests pass. Project input reviews still fail: two mechanical findings and 31 wiring findings (reports beside this document). Tools are declaration checks, not collision solvers. Source archives (including Linux x64 executables) published on this project at 415d1de583b2a706e8f75de793ac8f69373f6071 and linked from AIFlow #60. Shared registry releases and full geometry solver remain unfinished. The old service-review JSON is not evidence bound to board-17.+## Mechanical geometry implementation -## PCBWay publication+The mechanical tool now performs actual CadQuery/OCCT intersections of continuous conservative cylindrical tool sweeps with STEP solids. It supports fixed-axis translation through approach, engagement, withdrawal and extraction. Angled articulation is refused. Intended contact/removal exclusions require reasons; excluding every solid is refused. -Corrected .gitignore so the declared bin/ is included. App hero still missing; Hero Studio preview preparation is in progress. Its first Generate requires the human. Ordinary wiki writes now work; attachment upload still returned 401, so archives were published through repo push. PCBWay source archive is published on this project at 6e2a0222e61546f268f019d0dff396bcc4a80776. The separate app page and package release remain pending. CLI workflow tests pass, including default webview, explicit Pup, stale evidence and partial-price rejection. No new RFQ or payment submitted.+Nine geometry/CLI tests pass, including a real STEP hole, an oversized colliding tool, stale geometry, missing stages and a bare verification Boolean. Two Rust tests also pass. These are synthetic regression fixtures, not electronic-load acceptance. Reports retain `physicalQualification: false`; assembly completeness, registration, actual tools, tolerance and torque still require review. -## Media+The updated source archive is `adom-aiflow-mechanical-review-source.tar.gz`. Actual project reviews still have unresolved mechanical/wiring findings; see the adjacent reports. Wiring currently audits declarations and conductor IDs, not arbitrary mesh collisions. -No clip recorded for these repairs: AIFlow reported no PCB editor open on its selected capture machine. Native edits ran headlessly on arav-rog. Do not represent these as recorded live UI work.+## Release evidence -## Additional release dependencies+- Shared JLC rule source: `e15d2c4f0847b3850e7ca95983247afd67def605`.+- AIFlow geometry source: `4f0f19fe412eccd9811ef08a5ea263834a17458b`.+- AIFlow 0.2.26 installed/release binary SHA-256: `ada29f3ec618e7875cca2d6b2fb71b930c6a2f219a9a123a955a45e36cb1a947`; existing CLI help unchanged.+- PCBWay 0.1.1 installed/release binary SHA-256: `faa040942eae9cf56f314039156603a4d46f69386c314d64b6638d3b600ca911`.+- PCBWay workflow tests cover incomplete totals, changed inputs, stale exports, duplicate initialization, vendor receipts, webview default, explicit Pup and account identity. -Hero Studio preview opened on port 8967 but cannot load the private Adom brand guide with the expired identity; no approved hero generated. Mechanical/wiring packaging also needs truthful showcase images and approved heroes. The JLC workflow skill now instructs checking all-copper coverage; source guidance is now published; installed availability remains separate.+## Media -Corrected native verification: board-17 with its exact .kicad_pro/.kicad_dru has zero errors, zero opens and 66 footprint-library warnings. The earlier 432-warning report used missing/default project settings and is superseded by board17-matched-drc.json plus board17-native-verification.json. A two-via spacing experiment was not adopted: the actual project rules already accept baseline spacing. Library warning disposition and manufacturing qualification remain open.+A new native Pup-window walkthrough was captured on arav-rog, with Adom TTS narration prepared. Editing and validation are in progress. This is a retrospective walkthrough of the published tool; headless native CAD edits were not recorded as live UI work. Raw recording remains on arav-rog; no burned-in captions are planned. +## Publication dependency -Final native-context correction: restored three missing active-run library files from current-repair-r7 (H_NTC service hole, J10 PH connector and TP16 compact test point). With the full library table and exact board/project/rules hashes, native KiCad 10.0.3 reports zero errors, zero warnings and zero opens. See board17-recovered-libraries-drc.json and board17-native-verification.json. Board geometry is unchanged by the library repair.+The PCBWay hero approval is complete. Reusing its approved style for the Mechanical/Wiring pages is awaiting the user's answer to the explicit Hero Studio batch-approval question. Their source archives remain available here meanwhile.