project
Adom Custom Electronic Load
Public Made by Adomby adom
Two-layer digitally controlled electronic-load prototype. Compact R11 is under active electrical, cooling and probe-access review; not a manufacturing release.
← Commit history
Document unchanged-limit thermal margin and concrete physical qualification dependencies
6 files changed
+333−1
aiflow/run/physical-qualification-dependency.jsonadded+28@@ -0,0 +1,28 @@+{+ "kind": "external-dependency",+ "category": "physical-evidence",+ "reason": "Thermal acceptance requires installed low-rise cooling and sensor/lag evidence that is not available from catalog values or CAD. Current candidate is not qualified and the bring-up image is permanently output locked.",+ "dependency": "A reviewed assembled-prototype qualification setup and measured thermal/fault traces, plus verified 3rdPartyFab minimum finished surface/barrel copper. Supplier data must establish the actual TIM/clamp and installed sink assumptions before those can be adopted.",+ "resumeWhen": "Prototype availability, the finished-copper specification, or supported supplier/interface data is supplied; recheck current run and continue the corresponding design or measurement task. No cooling-size choice is required.",+ "attemptedRemedies": [+ "Completed larger-cooler fan and harness routing with component/probe clearance checks.",+ "Downloaded and inspected exact manufacturer sink CAD privately; checked top-entry tool paths against fins and proposed through-base bores.",+ "Computed unchanged-limit thermal margin and documented missing low-rise/orientation/obstruction conditions.",+ "Kept physical capture template unmeasured and firmware output locked; did not fabricate calibration.",+ "Completed independent control-session reconnect repair, host tests, disconnected panel review and source publication.",+ "Reconciled current electrical BOM and 17 previously unpriced inventory groups; no orders or stock mutations.",+ "Recorded and reviewed two additional model inspection clips; narration failure handed to TTS owner."+ ],+ "evidenceFiles": [+ "mechanical/passive-assembly-study/top-access-fin-review.json",+ "mechanical/passive-assembly-study/thermal-margin.json",+ "qualification/thermal-capture-readiness.json",+ "docs/cooling-evidence-request.md",+ "docs/finished-copper-review.md",+ "checkpoints/panel-reconnect/panel-review.json",+ "docs/cost/inventory-2026-10-12/review.json"+ ],+ "availableWork": [],+ "recordedAt": "2026-10-12T04:15:12.287738+00:00",+ "engineeringComplete": false+}
checkpoints/passive-top-access/publication.jsonadded+6@@ -0,0 +1,6 @@+{+ "sourceCommit": "ae78bc0b0a440ae414e5c488987e34e53073c084",+ "inventoryReadbackMatches": true,+ "sha256": "f3bc75ac2176c6a41b05819f26ce3a129aecd0bb1ade9ac3d2a425a421ea8915",+ "registryReleasePerformed": false+}
docs/completion-plan.md+11−1@@ -23,7 +23,7 @@ Scaffold fit: adopted board30 uses64×72mm corner spans on the verified8mm mediu 2. Establish installed airflow and fault operation. Fan RPM does not prove airflow; a blocked fan may keep spinning. Package-cooling sensitivity predicts approximately 75.6 C still / 51.1 C moving under assumed sink values. These are not measured or accepted results. Preserve the full-power still-air failure and solve the actual cooling/fault strategy. 3. After supported physical/spec changes, rerun exact-input current and thermal acceptance. Continue fields, net tour, silkscreen, native 3D, finish and export in enforced order. Review-only manufacturing exports already exist; do not present them as released. 4. Complete firmware/calibration and molecule integration. Control panel 0.0.6 drives the digital rotor only from fresh valid hardware RPM; stale/disconnected means unknown/paused. Host tests pass; output remains locked and hardware unflashed. [Fan shutdown review](fan-shutdown-review.md) adds 240 synthetic scheduler/clock-wrap integration cases, all passing. Physical timing, sensor calibration and load accuracy remain unverified.-5. Complete procurement and component provenance. [Cost review](cost/README.md) lists $77.39 in indicative listings, with bulk-tier, internal inventory and unavailable-part exclusions and substantial assembly/process exclusions. Candidate hardware is not an approved BOM.+5. Complete procurement and component provenance. [Cost review](cost/README.md) now reconciles the current Board32 BOM: $43.81 priced electrical listings; 15 passive MPNs have separately reported inventory costs and sell prices, but only three report enough stock. Partial amounts using passive sell prices total $77.30 with the compact sink or $102.96 with one larger stock extrusion. Machine contacts, process costs and qualification remain excluded. Candidate hardware is not an approved BOM. 6. Continue significant-action captures. Inventory is 129 raw native takes, 59 reviewed excerpts (including separately labelled headless reviews/replays) and 42 storyboard candidates, plus two separately labeled solver-event recordings (one reviewed, one superseded). Draft narration lives in `videos/narrated-review` and `videos/board32-results-review`; all42storyboard candidates now contain an audio stream, with human editorial review still pending; storyboard is `videos/build-storyboard.json`, port 8798. Obtain per-clip feedback before final assembly as required by aiflow-process-video. No final film exists. ## Tool and delivery boundaries@@ -163,3 +163,13 @@ Temperature guard source published as6d899788682379e0168e97645c4777c6ba4f48aa an Resumed on the user instruction "keep going then". Continue the larger passive-cooler candidate as a reversible working assumption, preserving all ratings and gates. The earlier aiflow/run/cooling-direction-dependency.json is historical and must not authorize another stop. Existing supervisor resumed after exact-thread runtime inspection. Mated-assembly study now shifts the sink +0.5mm in X and -0.5mm in Y, raises the fan20.05mm and reroutes three leads. No PCB/BOM adoption or thermal pass. Continue support, service access and manufacturer geometry checks. Control-panel0.0.6 refreshes its command token on SSE reconnect, immediately locks controls on link loss, ignores stale replies and never replays control commands. Session race tests, an actual browser synthetic restart test and nine controller tests pass. Task server restarted on the same45958 port after verifying no configured/connected instrument; live disconnected review passes. Existing older browser frames need a one-time reload. No new visible tab or hardware operation.++## Latest continuation checkpoint, 12 October++Top-access cooler retention was checked against the actual manufacturer fin model. Centered screw/driver paths have zero nominal intersections; three through-base holes are proposed. The rejected off-center locations remain in evidence. The carrier still requires material, joint, strength, tolerance and physical service validation; it is not adopted. See `mechanical/passive-assembly-study/top-access-fin-review.json` and `carrier-top-access-review.json`. Vendor CAD remains local-only.++Control-panel 0.0.6 refreshes connection credentials after SSE reconnection and invalidates stale asynchronous responses without automatically reconnecting, arming or replaying instrument commands. Host tests and a read-only real disconnected-server review pass. Existing older browser frames require one reload to load the new frontend. Firmware remains output locked and unflashed.++Two additional saved-model inspection clips were recorded and reviewed, bringing the excerpt inventory to 59. They are explicitly headless model inspections, not native authoring footage. New narration is blocked by the TTS backend's upstream 403, tracked in adom/adom-tts#8. Existing 42 narrated storyboard candidates remain unchanged; per-clip human editorial review is still needed before final film assembly.++The next acceptance dependency is physical evidence, not a cooling-size decision. See `aiflow/run/physical-qualification-dependency.json`. Prototype availability and finished-copper specification have been requested; neither has been supplied in this continuation. The older cooling-direction stop is obsolete. No acceptance gate has passed on the strength of catalog or nominal CAD data.
docs/cooling-evidence-request.md+6@@ -17,3 +17,9 @@ Use [the thermal capture procedure](thermal-bench-capture.md) with the exact boa Current package studies remain conditional: the compact sink fails the full-power still-air screen. Passing a software shutdown test does not cure that failure. A supported cooling design change and fresh exact-input analysis are required before AIFlow thermal acceptance; physical results may reveal further required changes. Neither an approximate fan curve nor a fabricated calibration value may close the gate. No production image should be enabled from this checklist. The current bring-up build remains permanently output locked.++## Larger 125319 candidate: numerical acceptance target++The [conditional margin study](../mechanical/passive-assembly-study/thermal-margin.json) holds the existing 5.5 W guard power, 40 °C ambient and 55 °C case ceiling. With the unqualified 0.52731 K/W case-to-sink allowance, the installed sink-to-air resistance would need to be below 2.19996 K/W. This is about 1.445 times the 1.522 K/W product-page value, before measurement and transient uncertainty. This ratio is an allowable budget, not a prediction of installed degradation.++Ask for natural-convection data at the actual low temperature rise, cut length, surface finish, heat-source area/location and orientation, including the stationary fan/carrier obstruction. The catalog identifies a three-inch natural-convection specimen but does not specify enough conditions to establish our installed result. Keep the failed compact-sink still-air result and all physical gates open. No supplier message has been sent.
mechanical/passive-assembly-study/thermal-margin.jsonadded+267@@ -0,0 +1,267 @@+{+ "status": "conditional-budget-not-qualification",+ "accepted": false,+ "boardSha256": "ea37ce6db20bae331bf41b6638fe9149a17c484e01bc2a0d7fd34917203b7fc3",+ "powerW": 5.5,+ "ambientC": 40.0,+ "caseCeilingC": 55.0,+ "assumedCaseToSinkKPerW": 0.52731,+ "catalogSinkToAmbientKPerW": 1.522,+ "maximumInstalledSinkToAmbientKPerWUnderAssumedInterface": 2.199962727272727,+ "maximumDegradationFactorUnderAssumedInterface": 1.4454420021502805,+ "conditionalCaseAtCatalogC": 51.271205,+ "catalogSources": [+ "https://wakefieldthermal.com/wakefield-thermal-3x12-in-extrusion-9099-125319/",+ "https://wakefieldthermal.com/content/Short-Length-Single-Sheets/Short-Length_WFT_125319%20%26%20125320.pdf"+ ],+ "limitations": [+ "Catalog identifies natural convection for a three-inch specimen but does not establish the temperature rise, heat-source footprint or orientation applicable here.",+ "Do not assume constant thermal resistance at low temperature rise. No convection scaling law is asserted for this product.",+ "Carrier, stopped fan, wire and workcell obstruction are unmeasured.",+ "Case-to-sink value includes assumed interface and spreading; clamp, flatness, grease and contact area are unqualified.",+ "No allowance for measurement uncertainty or sensor lag is consumed by this mathematical boundary. Bench acceptance must include those uncertainties.",+ "No operating limit, material, assembly or AIFlow gate was changed."+ ],+ "scenarios": [+ {+ "assumedCaseToSinkKPerW": 0.3,+ "assumedSinkDegradationFactor": 1.0,+ "assumedSinkToAmbientKPerW": 1.522,+ "calculatedCaseC": 50.021,+ "marginToCaseCeilingC": 4.978999999999999,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.3,+ "assumedSinkDegradationFactor": 1.1,+ "assumedSinkToAmbientKPerW": 1.6742000000000001,+ "calculatedCaseC": 50.8581,+ "marginToCaseCeilingC": 4.1419,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.3,+ "assumedSinkDegradationFactor": 1.25,+ "assumedSinkToAmbientKPerW": 1.9025,+ "calculatedCaseC": 52.11375,+ "marginToCaseCeilingC": 2.886249999999997,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.3,+ "assumedSinkDegradationFactor": 1.4,+ "assumedSinkToAmbientKPerW": 2.1308,+ "calculatedCaseC": 53.3694,+ "marginToCaseCeilingC": 1.6306000000000012,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.3,+ "assumedSinkDegradationFactor": 1.5,+ "assumedSinkToAmbientKPerW": 2.283,+ "calculatedCaseC": 54.2065,+ "marginToCaseCeilingC": 0.7935000000000016,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.3,+ "assumedSinkDegradationFactor": 2.0,+ "assumedSinkToAmbientKPerW": 3.044,+ "calculatedCaseC": 58.391999999999996,+ "marginToCaseCeilingC": -3.391999999999996,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 0.52731,+ "assumedSinkDegradationFactor": 1.0,+ "assumedSinkToAmbientKPerW": 1.522,+ "calculatedCaseC": 51.271205,+ "marginToCaseCeilingC": 3.728794999999998,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.52731,+ "assumedSinkDegradationFactor": 1.1,+ "assumedSinkToAmbientKPerW": 1.6742000000000001,+ "calculatedCaseC": 52.108305,+ "marginToCaseCeilingC": 2.8916949999999986,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.52731,+ "assumedSinkDegradationFactor": 1.25,+ "assumedSinkToAmbientKPerW": 1.9025,+ "calculatedCaseC": 53.363955,+ "marginToCaseCeilingC": 1.6360450000000029,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.52731,+ "assumedSinkDegradationFactor": 1.4,+ "assumedSinkToAmbientKPerW": 2.1308,+ "calculatedCaseC": 54.619605,+ "marginToCaseCeilingC": 0.38039500000000004,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.52731,+ "assumedSinkDegradationFactor": 1.5,+ "assumedSinkToAmbientKPerW": 2.283,+ "calculatedCaseC": 55.456705,+ "marginToCaseCeilingC": -0.4567049999999995,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 0.52731,+ "assumedSinkDegradationFactor": 2.0,+ "assumedSinkToAmbientKPerW": 3.044,+ "calculatedCaseC": 59.642205000000004,+ "marginToCaseCeilingC": -4.642205000000004,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 0.75,+ "assumedSinkDegradationFactor": 1.0,+ "assumedSinkToAmbientKPerW": 1.522,+ "calculatedCaseC": 52.496,+ "marginToCaseCeilingC": 2.503999999999998,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.75,+ "assumedSinkDegradationFactor": 1.1,+ "assumedSinkToAmbientKPerW": 1.6742000000000001,+ "calculatedCaseC": 53.3331,+ "marginToCaseCeilingC": 1.6668999999999983,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.75,+ "assumedSinkDegradationFactor": 1.25,+ "assumedSinkToAmbientKPerW": 1.9025,+ "calculatedCaseC": 54.58875,+ "marginToCaseCeilingC": 0.41125000000000256,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 0.75,+ "assumedSinkDegradationFactor": 1.4,+ "assumedSinkToAmbientKPerW": 2.1308,+ "calculatedCaseC": 55.8444,+ "marginToCaseCeilingC": -0.8444000000000003,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 0.75,+ "assumedSinkDegradationFactor": 1.5,+ "assumedSinkToAmbientKPerW": 2.283,+ "calculatedCaseC": 56.6815,+ "marginToCaseCeilingC": -1.6814999999999998,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 0.75,+ "assumedSinkDegradationFactor": 2.0,+ "assumedSinkToAmbientKPerW": 3.044,+ "calculatedCaseC": 60.867000000000004,+ "marginToCaseCeilingC": -5.867000000000004,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.0,+ "assumedSinkDegradationFactor": 1.0,+ "assumedSinkToAmbientKPerW": 1.522,+ "calculatedCaseC": 53.871,+ "marginToCaseCeilingC": 1.1289999999999978,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 1.0,+ "assumedSinkDegradationFactor": 1.1,+ "assumedSinkToAmbientKPerW": 1.6742000000000001,+ "calculatedCaseC": 54.7081,+ "marginToCaseCeilingC": 0.29189999999999827,+ "withinCeilingUnderAssumptions": true+ },+ {+ "assumedCaseToSinkKPerW": 1.0,+ "assumedSinkDegradationFactor": 1.25,+ "assumedSinkToAmbientKPerW": 1.9025,+ "calculatedCaseC": 55.96375,+ "marginToCaseCeilingC": -0.9637499999999974,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.0,+ "assumedSinkDegradationFactor": 1.4,+ "assumedSinkToAmbientKPerW": 2.1308,+ "calculatedCaseC": 57.2194,+ "marginToCaseCeilingC": -2.2194000000000003,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.0,+ "assumedSinkDegradationFactor": 1.5,+ "assumedSinkToAmbientKPerW": 2.283,+ "calculatedCaseC": 58.0565,+ "marginToCaseCeilingC": -3.0564999999999998,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.0,+ "assumedSinkDegradationFactor": 2.0,+ "assumedSinkToAmbientKPerW": 3.044,+ "calculatedCaseC": 62.242000000000004,+ "marginToCaseCeilingC": -7.242000000000004,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.25,+ "assumedSinkDegradationFactor": 1.0,+ "assumedSinkToAmbientKPerW": 1.522,+ "calculatedCaseC": 55.246,+ "marginToCaseCeilingC": -0.24600000000000222,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.25,+ "assumedSinkDegradationFactor": 1.1,+ "assumedSinkToAmbientKPerW": 1.6742000000000001,+ "calculatedCaseC": 56.0831,+ "marginToCaseCeilingC": -1.0831000000000017,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.25,+ "assumedSinkDegradationFactor": 1.25,+ "assumedSinkToAmbientKPerW": 1.9025,+ "calculatedCaseC": 57.33875,+ "marginToCaseCeilingC": -2.3387499999999974,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.25,+ "assumedSinkDegradationFactor": 1.4,+ "assumedSinkToAmbientKPerW": 2.1308,+ "calculatedCaseC": 58.5944,+ "marginToCaseCeilingC": -3.5944000000000003,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.25,+ "assumedSinkDegradationFactor": 1.5,+ "assumedSinkToAmbientKPerW": 2.283,+ "calculatedCaseC": 59.4315,+ "marginToCaseCeilingC": -4.4315,+ "withinCeilingUnderAssumptions": false+ },+ {+ "assumedCaseToSinkKPerW": 1.25,+ "assumedSinkDegradationFactor": 2.0,+ "assumedSinkToAmbientKPerW": 3.044,+ "calculatedCaseC": 63.617000000000004,+ "marginToCaseCeilingC": -8.617000000000004,+ "withinCeilingUnderAssumptions": false+ }+ ]+}
tools/passive_thermal_margin.pyadded+15@@ -0,0 +1,15 @@+#!/usr/bin/env python3+"""Conditional thermal budget, not an installed-performance prediction."""+from pathlib import Path+import json,hashlib,math+ROOT=Path(__file__).resolve().parents[1]+power=5.5;ambient=40.;limit=55.;interface=.52731;catalog=1.522+maximum=(limit-ambient)/power-interface+rows=[]+for rcs in [.3,.52731,.75,1.,1.25]:+ for factor in [1.,1.1,1.25,1.4,1.5,2.]:+ rsa=catalog*factor;case=ambient+power*(rcs+rsa)+ rows.append({'assumedCaseToSinkKPerW':rcs,'assumedSinkDegradationFactor':factor,'assumedSinkToAmbientKPerW':rsa,'calculatedCaseC':case,'marginToCaseCeilingC':limit-case,'withinCeilingUnderAssumptions':case<=limit})+r={'status':'conditional-budget-not-qualification','accepted':False,'boardSha256':hashlib.sha256((ROOT/'aiflow/run/board-32.kicad_pcb').read_bytes()).hexdigest(),'powerW':power,'ambientC':ambient,'caseCeilingC':limit,'assumedCaseToSinkKPerW':interface,'catalogSinkToAmbientKPerW':catalog,'maximumInstalledSinkToAmbientKPerWUnderAssumedInterface':maximum,'maximumDegradationFactorUnderAssumedInterface':maximum/catalog,'conditionalCaseAtCatalogC':ambient+power*(interface+catalog),'catalogSources':['https://wakefieldthermal.com/wakefield-thermal-3x12-in-extrusion-9099-125319/','https://wakefieldthermal.com/content/Short-Length-Single-Sheets/Short-Length_WFT_125319%20%26%20125320.pdf'],'limitations':['Catalog identifies natural convection for a three-inch specimen but does not establish the temperature rise, heat-source footprint or orientation applicable here.','Do not assume constant thermal resistance at low temperature rise. No convection scaling law is asserted for this product.','Carrier, stopped fan, wire and workcell obstruction are unmeasured.','Case-to-sink value includes assumed interface and spreading; clamp, flatness, grease and contact area are unqualified.','No allowance for measurement uncertainty or sensor lag is consumed by this mathematical boundary. Bench acceptance must include those uncertainties.','No operating limit, material, assembly or AIFlow gate was changed.'],'scenarios':rows}+out=ROOT/'mechanical/passive-assembly-study/thermal-margin.json';out.write_text(json.dumps(r,indent=2)+'\n')+print(json.dumps({k:v for k,v in r.items() if k!='scenarios'},indent=2))