project
Adom Custom Electronic Load
Public Made by Adomby adom
Two-layer digitally controlled electronic-load prototype. Compact R11 is under active electrical, cooling and probe-access review; not a manufacturing release.
← Commit history
aiflow run board-codex-20261007-1749: thermal-vias
3 files changed
+22−10
docs/runs/board-codex-20261007-1749/README.md+22−10@@ -1,6 +1,6 @@ # AI Flow run: codex on board-0 -**Running**: step `routing`, 437.4 min of AI time since the prompt (2757.3 min on the wall clock). This page updates at every step change.+**Running**: step `thermal-vias`, 470.8 min of AI time since the prompt (2810.1 min on the wall clock). This page updates at every step change. Prompt at 2026-10-07T17:49:14Z (UTC). Flow: board. Every number here is from the run's append-only ledger (run.jsonl). AI time is the time the AI was working on a prompt: from the human's prompt to the AI's done, with any gap over 15 min where no command ran (unobserved, not proven idle) cut out. @@ -18,8 +18,8 @@ One row per human prompt: the AI's time on it, unobserved gaps excluded by the h | 6 | 2026-10-09T10:28:54Z | (open) | 13.9 | 35 | Continue electronic-load engineering through AIFlow, with real dashboard progress and clip | | 7 | 2026-10-09T11:18:03Z | (open) | 4.6 | 69 | Keep going on AIFlow: continue electronic-load engineering and recorded board work. | | 8 | 2026-10-09T12:31:28Z | (open) | 24.5 | 31 | Resume the electronic load through all AIFlow design gates after dashboard corrections; co |-| 9 | 2026-10-09T13:26:48Z | (open) | 139.7 | 0 | Continue original electronic-load objective. Compact 5 W prototype is the working basis fr |-| **all** | | | **437.4** | | |+| 9 | 2026-10-09T13:26:48Z | (open) | 173.1 | 19 | Continue original electronic-load objective. Compact 5 W prototype is the working basis fr |+| **all** | | | **470.8** | | | ## Per step @@ -29,15 +29,15 @@ AI time only, the idle cut out. |---|---|---|---|---|---|---|---| | intake | 2.6 | 0.3 | 2.2 | 3 | 1 | 0 | 0.3 min | | placement | 9.0 | 0.0 | 9.0 | 28 | 4 | 3 | 0.0 min |-| routing | 46.6 | 0.0 | 46.6 | 47 | 5 | 1 | 0.0 min |+| routing | 59.2 | 0.0 | 59.2 | 67 | 5 | 1 | 0.0 min | | components | 11.9 | 0.0 | 11.9 | 28 | 1 | 0 | 0.0 min | | design | 2.5 | 0.0 | 2.5 | 11 | 1 | 0 | 0.0 min | | libraries | 1.4 | 0.0 | 1.4 | 6 | 1 | 0 | 0.0 min | | models | 0.6 | 0.0 | 0.6 | 4 | 1 | 0 | 0.0 min |-| rules | 343.3 | 0.0 | 343.3 | 14 | 1 | 0 | 0.0 min |+| rules | 364.1 | 0.0 | 364.1 | 14 | 1 | 0 | 0.0 min | | test-plan | 0.1 | 0.0 | 0.1 | 5 | 1 | 0 | 0.0 min |-| thermal-vias | 19.5 | 0.0 | 19.5 | 120 | 3 | 0 | 0.0 min |-| **total** | **437.4** | **0.3** | **437.1** | | | | |+| thermal-vias | 19.5 | 0.0 | 19.5 | 121 | 4 | 0 | 0.0 min |+| **total** | **470.8** | **0.3** | **470.5** | | | | | ## Returns to earlier steps @@ -75,9 +75,15 @@ AI time only, the idle cut out. - 2026-10-09T15:43:01Z clip-start:placement-4 - 2026-10-09T15:44:09Z capture-stop - 2026-10-09T15:46:31Z clip-start:routing-5+- 2026-10-09T15:47:39Z capture-stop+- 2026-10-09T16:06:04Z capture-start+- 2026-10-09T16:07:11Z capture-stop ## Where the board stands +- routing: 0 unrouted after null passes+- gate: 0 new DRC errors, 0 unconnected, null inherited+- landed live: 0 of 0 route entries ## The steps on camera @@ -331,7 +337,13 @@ Why the AI came back here: Rotate D1 and reroute power paths after native DRC an What this step does: route to 100 percent with the spec's rules, gate with KiCad's DRC, land as undo steps; the AI takes it with take route=ai -**Clip: routing, visit 5, still recording (started 2026-10-09T15:46:31Z); it appears here when the step ends.**+**Clip: routing, visit 5, the PCB editor from 2026-10-09T15:46:31Z to 2026-10-09T15:47:39Z. Motion only: 1.1 min of real time, 1 s of it had something moving; the clock in the corner is the real elapsed time.**++<video width="100%" controls><source src="/blob/app/adom-custom-electronic-load/docs/runs/board-codex-20261007-1749/routing-5.mp4" type="video/mp4"></video>++**Contact sheet: nine frames spread through the routing, visit 5 clip, what the camera saw.**++ **Screenshot: the board when routing, visit 5 began.** @@ -343,10 +355,10 @@ Percent of each plan limit used, as the provider reports it, at the start of the | Provider | Limit | At start | At end | Used by this run | |---|---|---|---|---|-| claude | 5h | 17 % | 0 % | -17.0 % |+| claude | 5h | 17 % | 3 % | -14.0 % | | claude | Fable | 0 % | 3 % | 3.0 % | | claude | week | 54 % | 69 % | 15.0 % |-| codex | week | 2 % | 30 % | 28.0 % |+| codex | week | 2 % | 32 % | 30.0 % | *The limits are per account, not per run: every AI thread signed in as this user draws on the same numbers, so a run made while other threads were working shows their usage too. Read it as an upper bound unless this run was the only thread active.*
docs/runs/board-codex-20261007-1749/routing-5-sheet.pngadded⋯ 1 unchanged line ⋯
docs/runs/board-codex-20261007-1749/routing-5.mp4added⋯ 1 unchanged line ⋯