← Commit history
Add narrated fused-supply elbow correction review with separate captions
5 files changed
+30
docs/remote-service-clips.md+8@@ -1,3 +1,11 @@+# Latest: current-path repair++18-second narrated R5/R7 native-route comparison. The fused-supply elbow shifts and widens without entering the washer keepout. The0.1mm Fields peak drops69.78→59.72A/mm²; the limit remains60 and the small0.47% margin is disclosed. Native DRC0/0 and six nominal probing stages pass. Thermal and physical qualification remain open.++::adom-video{video="/adom/adom-custom-electronic-load/render/videos/remote-service/current-repair-review.mp4" poster="/adom/adom-custom-electronic-load/render/videos/remote-service/current-repair-review.jpg" captions="/adom/adom-custom-electronic-load/render/videos/remote-service/current-repair-review.vtt"}++This is a recorded geometry review with measured screening results, not footage of the original CAD edits or a field-color rendering. Recording and rendering used arav-rog. Captions are separate; no burned narration subtitles.+ # Latest: Q1 cooling-path review 21-second narrated review of the R6 exploratory thermal scenario. The actual PCB field map and lumped junction/case/heatsink results switch from assumed airflow to still air on the same color scale. This is **not** a spatial 3D heatsink simulation, measured temperature, or validated power rating. The model uses Q1 at5.5W; the5W bring-up cap and output lock remain.
videos/remote-service/current-repair-recording.jsonadded+8@@ -0,0 +1,8 @@+{ + "file": "C:\\Users\\arav\\adom-projects\\electronic-load-media\\videos\\remote-service\\current-repair-review.mp4", + "seconds": 17.862583333333333, + "captionsBurned": false, + "narration": "Adom TTS Andrew +15%, silences trimmed", + "rawHost": "arav-rog", + "scope": "Recorded native R5/R7 route-geometry comparison; numbers from immutable Fields solves. Not live editing or physical qualification." +}
videos/remote-service/current-repair-review.jpgadded⋯ 1 unchanged line ⋯
videos/remote-service/current-repair-review.mp4added⋯ 1 unchanged line ⋯
videos/remote-service/current-repair-review.vttadded+14@@ -0,0 +1,14 @@+WEBVTT + +00:00:00.000 --> 00:00:03.388 +The fused supply was still squeezing three amps around this bend. + +00:00:03.388 --> 00:00:07.699 +We shifted the elbow and widened its lower section, keeping the screw clearance intact. + +00:00:07.699 --> 00:00:14.167 +The peak falls from about seventy to just under sixty amps per square millimeter. That passes this screen with little margin. + +00:00:14.167 --> 00:00:17.863 +Native design checks are clean, but thermal and physical qualification remain open. +