docs/runs/compact-outline-candidate-codex-astra-20261013-2322/README.md+35−9
@@ -1,6 +1,6 @@ # AI Flow run: codex-astra on board-0 -**Running**: step `fields`, 208.4 min of AI time since the prompt (227.6 min on the wall clock). This page updates at every step change.+**Running**: step `components`, 262.7 min of AI time since the prompt (2147.6 min on the wall clock). This page updates at every step change.  Prompt at 2026-10-13T23:22:02.610999+00:00 (UTC). Flow: board. Every number here is from the run's append-only ledger (run.jsonl). AI time is the time the AI was working on a prompt: from the human's prompt to the AI's done, with any gap over 15 min where no command ran (unobserved, not proven idle) cut out. @@ -10,8 +10,16 @@ One row per human prompt: the AI's time on it, unobserved gaps excluded by the h  | Session | Prompt at | Done at | AI time min | Unobserved gap min | What | |---|---|---|---|---|---|-| 1 | 2026-10-13T23:22:02Z | (open) | 208.4 | 19 | the first prompt |-| **all** | | | **208.4** | | |+| 1 | 2026-10-13T23:22:02Z | 2026-10-14T03:24:17Z | 223.1 | 19 | the first prompt |+| 2 | 2026-10-14T03:24:17Z | (open) | 0.0 | 0 | follow-up (no prompt mark; say `prompt --text` next time) |+| 3 | 2026-10-14T13:20:36Z | (open) | 0.0 | 0 | follow-up (no prompt mark; say `prompt --text` next time) |+| 4 | 2026-10-14T13:20:36Z | (open) | 10.2 | 0 | ok, keep going then |+| 5 | 2026-10-14T13:30:45Z | (open) | 2.0 | 23 | keep going |+| 6 | 2026-10-14T13:55:18Z | 2026-10-14T23:36:24Z | 27.4 | 554 | go — proceed with explicitly documented geometry, interface and fan assumptions for protot |+| 7 | 2026-10-14T23:36:24Z | (open) | 0.0 | 0 | follow-up (no prompt mark; say `prompt --text` next time) |+| 8 | 2026-10-15T11:09:37Z | (open) | 0.0 | 0 | follow-up (no prompt mark; say `prompt --text` next time) |+| 9 | 2026-10-15T11:09:37Z | (open) | 0.0 | 0 | User requests correction of incomplete R11 delivery: identify J connectors, replace perime |+| **all** | | | **262.7** | | |  ## Per step @@ -25,20 +33,22 @@ AI time only, the idle cut out. | pours | 0.8 | 0.3 | 0.4 | 7 | 2 | 0 | 0.3 min | | current | 12.2 | 4.9 | 7.3 | 10 | 2 | 0 | 4.9 min | | thermal | 47.8 | 33.6 | 14.2 | 67 | 2 | 0 | 9.6 min |-| components | 3.4 | 3.2 | 0.3 | 3 | 1 | 0 | 1.2 min |+| 3d | 0.0 | 0.0 | 0.0 | 1 | 0 | 0 | 0.0 min |+| components | 3.4 | 3.2 | 0.3 | 4 | 2 | 1 | 1.2 min | | design | 14.6 | 14.3 | 0.3 | 6 | 1 | 0 | 13.3 min |-| fields | 0.0 | 0.0 | 0.0 | 1 | 1 | 0 | 0.0 min |+| fields | 54.2 | 54.1 | 0.2 | 27 | 1 | 0 | 34.5 min | | libraries | 19.3 | 17.6 | 1.7 | 14 | 1 | 0 | 8.0 min | | models | 9.5 | 7.5 | 1.9 | 4 | 1 | 0 | 6.9 min | | outline | 1.1 | 0.6 | 0.5 | 10 | 2 | 0 | 0.4 min | | rules | 1.8 | 1.3 | 0.5 | 3 | 1 | 0 | 1.2 min | | test-plan | 0.9 | 0.7 | 0.2 | 3 | 1 | 0 | 0.6 min | | thermal-vias | 50.3 | 37.3 | 13.1 | 60 | 2 | 0 | 6.1 min |-| **total** | **208.4** | **157.2** | **51.3** | | | | |+| **total** | **262.6** | **211.2** | **51.4** | | | | |  ## Returns to earlier steps  - 2026-10-14T01:58:41Z back to **placement** (visit 2): Corrected probing obstacle detection found cooler interference during ground-pin insertion and TP14 travel; propose moving J7 and TP14 into the left access corridor.+- 2026-10-15T11:09:38Z back to **components** (visit 2): User review exposed mechanical and harness inconsistencies, missing heatsink component contract, connector access and unfinished silkscreen; reopen design from component contracts.  ## Decisions along the way @@ -70,6 +80,14 @@ AI time only, the idle cut out. - 2026-10-14T02:54:46Z capture-stop - 2026-10-14T03:08:46Z artifact analysis-image for current-2: R11 v5 matched 0.1 mm filled-copper current screen; computed result, not hardware qualification. - 2026-10-14T03:08:46Z artifact analysis-image for thermal-2: R11 v5 external Q1 sensitivity only. Assumed interface and airflow; fan-off exceeds original budget. Not resolved fin CFD or thermal acceptance.+- 2026-10-14T03:09:39Z artifact process-video-review for fields-1: Actual v5 Fields net selection, 1.59x, captioned narration. Current-only presentation; thermal gate remains open. Awaiting user clip review.+- 2026-10-14T13:22:22Z artifact analysis-report for thermal-2: Q1 insulating interface screen: two documented pads do not substantiate prior 0.7 K/W assumption; thermal remains open+- 2026-10-14T13:32:46Z artifact analysis-image for thermal-2: Q1 insulating joint sensitivity; reference conditions only, no thermal acceptance+- 2026-10-14T14:02:39Z artifact review for fields-1: User-authorized assumption-based prototype scope; original limits and qualification gates retained+- 2026-10-14T22:10:12Z artifact review for thermal-2: Q1 full heat-path sensitivity: prototype assumptions, thermal qualification still open+- 2026-10-14T22:27:05Z artifact process-video for fields-1: 4:09 R10-to-R11 process edit; six R11 scenes explicitly approved; player captions separate; new assembly footage excluded+- 2026-10-14T23:34:23Z artifact prototype-review for fields-1: R11 assumed retained assembly: board-solid and internal-contact checks pass; corrected CLI replay has zero collisions/snags; hardware and browser parity remain unqualified.+- 2026-10-14T23:35:29Z artifact engineering-review for fields-1: All six retained-assembly CLI checks pass on hashed inputs and isolated solver; physical qualification and browser parity remain open.  ## Where the board stands @@ -419,6 +437,14 @@ What this step does: copper and vias at every hot tab against the rise budget; t  ![R11 v5 external Q1 sensitivity only. Assumed interface and airflow; fan-off exceeds original budget. Not resolved fin CFD or thermal acceptance.](/blob/app/adom-custom-electronic-load/docs/runs/compact-outline-candidate-codex-astra-20261013-2322/thermal-2-analysis-image-0.png) +**The AI's file: Q1 insulating interface screen: two documented pads do not substantiate prior 0.7 K/W assumption; thermal remains open** [thermal-2-analysis-report-1.md](/blob/app/adom-custom-electronic-load/docs/runs/compact-outline-candidate-codex-astra-20261013-2322/thermal-2-analysis-report-1.md)++**The AI's drawing: Q1 insulating joint sensitivity; reference conditions only, no thermal acceptance**++![Q1 insulating joint sensitivity; reference conditions only, no thermal acceptance](/blob/app/adom-custom-electronic-load/docs/runs/compact-outline-candidate-codex-astra-20261013-2322/thermal-2-analysis-image-2.png)++**The AI's file: Q1 full heat-path sensitivity: prototype assumptions, thermal qualification still open** [thermal-2-review-3.md](/blob/app/adom-custom-electronic-load/docs/runs/compact-outline-candidate-codex-astra-20261013-2322/thermal-2-review-3.md)+ ## Plan usage, the second cost line  Percent of each plan limit used, as the provider reports it, at the start of the run and at its end.@@ -426,9 +452,9 @@ Percent of each plan limit used, as the provider reports it, at the start of the | Provider | Limit | At start | At end | Used by this run | |---|---|---|---|---| | claude | 5h | 2 % | 3 % | 1.0 % |-| claude | Fable | 2 % | 2 % | 0.0 % |-| claude | week | 41 % | 41 % | 0.0 % |-| codex | week | 14 % | 27 % | 13.0 % |+| claude | Fable | 2 % | 4 % | 2.0 % |+| claude | week | 41 % | 58 % | 17.0 % |+| codex | week | 14 % | 0 % | -14.0 % |  *The limits are per account, not per run: every AI thread signed in as this user draws on the same numbers, so a run made while other threads were working shows their usage too. Read it as an upper bound unless this run was the only thread active.* 
docs/runs/compact-outline-candidate-codex-astra-20261013-2322/thermal-2-analysis-image-2.pngadded
⋯ 1 unchanged line ⋯
docs/runs/compact-outline-candidate-codex-astra-20261013-2322/thermal-2-analysis-report-1.mdadded+17
@@ -0,0 +1,17 @@+# Q1 interface review — 14 October 2026++The earlier 0.7 K/W interface remains an assumption. Two documented compliant insulating pads do not support that value in their manufacturer TO-220 tests.++| Candidate | TO-220 interface at 50 psi | Junction rise at 5.5 W, assuming 1.2 K/W sink |+|---|---:|---:|+| Earlier assumed interface | 0.70 K/W | 12.76 C |+| Henkel TSP 1600 | 2.45 K/W | 22.39 C |+| Henkel TSP 3500, 0.010 inch | 2.02 K/W | 20.02 C |++Calculation: 5.5 × (0.42 + interface + 1.2). This is a series-path screen, not Fields simulation or measured assembly performance. It neglects parallel heat through the PCB. Manufacturer TO-220 test values depend on pressure, surface and specimen; they are not guaranteed for this Q1 clamp. The 1.2 K/W sink scenario is also unqualified for our installed airflow.++Neither pad can be accepted from this screen against the unchanged 15 C rise budget. Do not interpret area-normalized C-in²/W as C/W, or use material conductivity alone as complete joint resistance. Do not increase clamp pressure without checking Q1 and sink mechanical limits. A ceramic insulating interface with controlled thin contact layers remains a candidate, not a selected qualified part.++Sources: [TSP 1600 manufacturer TDS](https://datasheets.tdx.henkel.com/BERGQUIST-SIL-PAD-TSP-1600-en_GL.pdf), [TSP 3500 manufacturer TDS](https://datasheets.tdx.henkel.com/BERGQUIST-SIL-PAD-TSP-3500-en_GL.pdf).++Next dependency: verified sink geometry and clamp conditions, exact insulating interface, installed airflow, then complete thermal and mechanical revalidation. Supplier requests were sent with user authorization; no purchase or fabrication release.
docs/runs/compact-outline-candidate-codex-astra-20261013-2322/thermal-2-review-3.mdadded+26
@@ -0,0 +1,26 @@+# Assumption-based Q1 cooling review++This is a prototype sensitivity calculation, not a resolved 3D fin-temperature analysis or thermal qualification. The command cap remains 5 W. The conservative screening source is 5.5 W at 40 °C ambient; the original junction-rise budget remains 15 °C.++The complete series path is Q1 junction → case (0.42 K/W) → electrical insulation and its two contacts → heatsink → ambient. The maximum total resistance at the screening point is 15/5.5 = **2.727 K/W**. After Q1's junction-to-case resistance, the interface and sink together must be at or below **2.307 K/W**.++| Assumed total interface | Maximum sink-to-air resistance to meet screening budget |+|---|---|+| 0.30 K/W | 2.007 K/W |+| 0.70 K/W | 1.607 K/W |+| 1.20 K/W | 1.107 K/W |+| 2.00 K/W | 0.307 K/W |++The nominal 0.70 K/W interface plus 1.20 K/W forced-air sink predicts a 12.76 °C junction rise (52.76 °C junction; 50.45 °C case). Replacing the sink assumption with 8 K/W for fan-off predicts a 50.16 °C junction rise (90.16 °C junction; 87.85 °C case). These are steady-state network predictions. The controller must disable load after fan failure; the fan-off result is retained as a failing case, not an allowed operating condition.++The 0.635 mm AlN wafer's calculated bulk resistance is only 0.0267 K/W at assumed 170 W/m·K and 140 mm² area. That does **not** establish the assembled interface resistance: contact films, flatness, hole area, pressure and spreading remain unknown. Do not replace the interface sweep with the bulk value. Supplier pad alternatives already examined have materially higher published resistance and must not inherit the nominal 0.70 K/W assumption.++The 21 ms hypothetical fault reaction adds 0.1155 J at 5.5 W. Without package transient impedance, thermal mass and sensor response, that energy cannot be converted into a trustworthy temperature rise. A case sensor also lags the junction. Neither a 55 °C case trip nor this energy calculation proves junction protection.++## Prototype decision++Proceed with the commercial-sink envelope, assumed AlN isolation, duct and side fan for fit and assembly review. Keep the output locked in the built firmware. Do not advertise increased wattage from the sweep's hypothetical power column. The successful probe replay and board-solid clearance checks do not validate airflow, clamping pressure, electrical isolation or cooling.++Before enabling load on hardware: verify isolation and assembly fit, measure fan PWM/tach behavior, instrument Q1 case and sink, ramp power under independent protection, characterize installed interface/sink resistance, and exercise fan-stall shutdown. Qualification remains open until those measurements support the original limits.++Source artifacts: `thermal-assumptions.json`, `thermal-sensitivity.csv`, `thermal-sensitivity.png`. This report addresses Q1's external thermal path; it does not replace D1/PCB thermal review.