← Commit history
Add narrated Q1 package-cooling scenario review with separate captions
5 files changed
+30
docs/remote-service-clips.md+8@@ -1,3 +1,11 @@+# Latest: Q1 cooling-path review++21-second narrated review of the R6 exploratory thermal scenario. The actual PCB field map and lumped junction/case/heatsink results switch from assumed airflow to still air on the same color scale. This is **not** a spatial 3D heatsink simulation, measured temperature, or validated power rating. The model uses Q1 at5.5W; the5W bring-up cap and output lock remain.++::adom-video{video="/adom/adom-custom-electronic-load/render/videos/remote-service/package-cooling-review.mp4" poster="/adom/adom-custom-electronic-load/render/videos/remote-service/package-cooling-review.jpg" captions="/adom/adom-custom-electronic-load/render/videos/remote-service/package-cooling-review.vtt"}++Raw recording, editing and rendered video remain on arav-rog. Adom TTS narration has long pauses removed; captions are separate. [Thermal assumptions and results](q1-package-cooling-review-2026-10-16.md).+ # Latest process clip: moving the fan connector clears the probe This 12-second narrated before/after model review shows J9 moving 3 mm toward the fan. All four wires follow the actual native connector position and become shorter. The candidate passes native DRC with zero violations/opens, static wire-solid clearance, and all six input-bound nominal probing stages. Physical qualification, browser/CLI tether parity, and electrical/thermal acceptance remain open. This is saved-model review footage, not a successful workcell replay or a fabrication release.
videos/remote-service/package-cooling-recording.jsonadded+8@@ -0,0 +1,8 @@+{ + "file": "C:\\Users\\arav\\adom-projects\\electronic-load-media\\videos\\remote-service\\package-cooling-review.mp4", + "seconds": 21.025541666666665, + "captionsBurned": false, + "narration": "Adom TTS Andrew +15%, silences trimmed", + "rawHost": "arav-rog", + "scope": "Recorded browser review of immutable R6 Fields maps and lumped Q1 package nodes; not spatial heatsink FEM or physical validation" +}
videos/remote-service/package-cooling-review.jpgadded⋯ 1 unchanged line ⋯
videos/remote-service/package-cooling-review.mp4added⋯ 1 unchanged line ⋯
videos/remote-service/package-cooling-review.vttadded+14@@ -0,0 +1,14 @@+WEBVTT + +00:00:00.000 --> 00:00:05.180 +Q1 does not cool through the board alone. This review adds its case, interface, and heatsink path. + +00:00:05.180 --> 00:00:10.665 +With the assumed cooling airflow, the model predicts a thirteen degree junction rise at five point five watts. + +00:00:10.665 --> 00:00:14.322 +In still air, that rises to fifty degrees and exceeds our budget. + +00:00:14.322 --> 00:00:21.026 +These are steady state estimates, not hardware validation. The current-density gate also remains open, so the board is not ready for release. +