project
Adom Custom Electronic Load
Public Made by Adomby adom
Two-layer digitally controlled electronic-load prototype. Compact R11 is under active electrical, cooling and probe-access review; not a manufacturing release.
← Commit history
aiflow run board-codex-20261007-1749: routing
3 files changed
+21−7
docs/runs/board-codex-20261007-1749/README.md+21−7@@ -1,6 +1,6 @@ # AI Flow run: codex on board-0 -**Running**: step `placement`, 84.8 min of AI time since the prompt (1217.9 min on the wall clock). This page updates at every step change.+**Running**: step `routing`, 93.4 min of AI time since the prompt (1226.5 min on the wall clock). This page updates at every step change. Prompt at 2026-10-07T17:49:14Z (UTC). Flow: board. Every number here is from the run's append-only ledger (run.jsonl). AI time is the time the AI was working on a prompt: from the human's prompt to the AI's done, with any gap over 15 min where no command ran (unobserved, not proven idle) cut out. @@ -13,8 +13,8 @@ One row per human prompt: the AI's time on it, unobserved gaps excluded by the h | 1 | 2026-10-07T17:49:14Z | (open) | 46.0 | 1019 | the first prompt | | 2 | 2026-10-08T11:34:31Z | (open) | 9.9 | 114 | User resumed custom electronic load work and reiterated recording clips for a YouTube buil | | 3 | 2026-10-08T13:38:16Z | (open) | 21.6 | 0 | Continue load design with fan tach and Kelvin-minus probe access; retain two-layer 3rdPart |-| 4 | 2026-10-08T13:59:54Z | (open) | 7.2 | 0 | Continue through remaining library, cooling, routing and recorded build work |-| **all** | | | **84.8** | | |+| 4 | 2026-10-08T13:59:54Z | (open) | 15.8 | 0 | Continue through remaining library, cooling, routing and recorded build work |+| **all** | | | **93.4** | | | ## Per step @@ -23,14 +23,15 @@ AI time only, the idle cut out. | Step | AI min | AI thinking min | Tool min | Turns | Visits | Returns | Longest think | |---|---|---|---|---|---|---|---| | intake | 2.6 | 0.3 | 2.2 | 3 | 1 | 0 | 0.3 min |-| placement | 0.0 | 0.0 | 0.0 | 1 | 1 | 0 | 0.0 min |+| placement | 1.1 | 0.0 | 1.1 | 4 | 1 | 0 | 0.0 min |+| routing | 0.0 | 0.0 | 0.0 | 1 | 1 | 0 | 0.0 min | | components | 11.9 | 0.0 | 11.9 | 28 | 1 | 0 | 0.0 min | | design | 2.5 | 0.0 | 2.5 | 11 | 1 | 0 | 0.0 min | | libraries | 1.4 | 0.0 | 1.4 | 6 | 1 | 0 | 0.0 min | | models | 0.6 | 0.0 | 0.6 | 4 | 1 | 0 | 0.0 min |-| rules | 65.8 | 0.0 | 65.8 | 14 | 1 | 0 | 0.0 min |+| rules | 73.2 | 0.0 | 73.2 | 14 | 1 | 0 | 0.0 min | | test-plan | 0.1 | 0.0 | 0.1 | 5 | 1 | 0 | 0.0 min |-| **total** | **84.8** | **0.3** | **84.5** | | | | |+| **total** | **93.4** | **0.3** | **93.1** | | | | | ## Decisions along the way @@ -42,6 +43,7 @@ AI time only, the idle cut out. - 2026-10-08T14:05:30Z capture-stop - 2026-10-08T14:06:02Z clip-start:test-plan-1 - 2026-10-08T14:07:02Z clip-start:placement-1+- 2026-10-08T14:10:02Z capture-stop ## Where the board stands @@ -118,12 +120,24 @@ What this step does: Think through how this board will be tested once it is buil What this step does: place the parts for routability, current and heat; the binary packs, checks courtyards and lands moves; reserve visible space for connector labels and the two-sided service silkscreen; the switch-node check refuses switch copper under another part or a switch loop longer than the spec allows, and sends the AI back here -**Clip: placement, still recording (started 2026-10-08T14:07:02Z); it appears here when the step ends.**+**Clip: placement, the PCB editor from 2026-10-08T14:07:02Z to 2026-10-08T14:10:02Z. Motion only: 3.0 min of real time, 3 s of it had something moving; the clock in the corner is the real elapsed time.**++<video width="100%" controls><source src="/blob/app/adom-custom-electronic-load/docs/runs/board-codex-20261007-1749/placement-1.mp4" type="video/mp4"></video>++**Contact sheet: nine frames spread through the placement clip, what the camera saw.**++ **Screenshot: the board when placement began.**  +### routing++What this step does: route to 100 percent with the spec's rules, gate with KiCad's DRC, land as undo steps; the AI takes it with take route=ai++**Clip: routing, still recording (started 2026-10-08T14:15:43Z); it appears here when the step ends.**+ ## Plan usage, the second cost line Percent of each plan limit used, as the provider reports it, at the start of the run and at its end.
docs/runs/board-codex-20261007-1749/placement-1-sheet.pngadded⋯ 1 unchanged line ⋯
docs/runs/board-codex-20261007-1749/placement-1.mp4added⋯ 1 unchanged line ⋯