← Commit history

Document supplier review and corrected thermal clip with separate captions

John Lauer ·105e8c3bbc · ·parent 6ee22c9
2 files changed +19
docs/completion-plan.md+9
@@ -113,3 +113,12 @@ A21-second narrated R6 thermal-review clip is rendered remotely on arav-rog, wit R4/R5/R7 recheck scripts hashed their intended new models but the copied probing state still selected the older fan-connector-clearance native board and GLB; the plan.board reference was older still. Those revision-specific probing passes are withdrawn. Current/DRC results are unaffected. R7 is now main AIFlow board-12 and its current gate passes, but its probing acceptance is pending a corrected rerun. The checker now resolves and compares actual state.board/state.glb/plan.board/release SHA before any command, and watches both display and plain models. Shared CLI identity checks and browser obstacle export are being tested. Historical generated reports remain as evidence of the defect, not acceptance.  The R6 thermal video's budget annotation is corrected from the general35°C board budget to the stricter Q1-specific15°C budget. Predicted rises remain49.55°C still and12.75°C moving; neither input nor acceptance limits changed.+++## 2026-10-16 supplier response and corrected thermal study++R7 exact-input probing and the explicit PS2/fan-motion candidate pass six nominal geometry stages. Browser evidence confirms rotor-only motion, pause/seek and shutdown. Linux and native Windows each pass 25 Rust tests; seven JavaScript checks pass. Published fan replay has separate captions and narration. Physical qualification remains false.++ATS's October14 response estimates 9 K/W natural convection for the fine-pitch sink and 4.6 K/W for its coarse-pitch alternative, with catalog heating over the full40x40mm base. Both exceed the existing passive budget under the stated interface assumption. Supplier CAD is not redistributable and stays outside the public repo. Same Sky detailed fan data remains outstanding.++Corrected the older oversized12x18mm Q1 contact by adding a separate assumed8x10mm contact sensitivity at5.5W: case82.44°C with h5 and49.20°C with h50, ambient40°C. Mesh change1→2mm shifts maxima<0.08°C. Neither prescribed h nor contact shape is measured. The narrated17-second layer-reveal clip is on the latest-clips page; raw media stays on arav-rog. Main thermal acceptance stays failed, output locked, original5W cap unchanged. Supplier-informed coupled solve remains separate from accepted spec.
docs/remote-service-clips.md+10
@@ -1,3 +1,13 @@+# Latest: corrected Q1 contact and 3D heat path++17-second narrated native-window review: reveal the assumed Q1 contact, add the heatsink base and fins, then compare the two prescribed convection cases. The earlier oversized contact patch is corrected to an explicitly assumed 8 × 10 mm patch. **Steady-state sensitivity only, not measured fan performance or a new power rating.**++::adom-video{video="/adom/adom-custom-electronic-load/render/videos/remote-service/thermal-contact-review.mp4" poster="/adom/adom-custom-electronic-load/render/videos/remote-service/thermal-contact-review.jpg" captions="/adom/adom-custom-electronic-load/render/videos/remote-service/thermal-contact-review.vtt"}++Captured and rendered on arav-rog with continuous Adom TTS and separate captions. The switch compares two solved states; it is not a cooling transient. [Thermal evidence and supplier response review](r7-probing-and-thermal-review.md).++---+ # Latest: fan state follows auxiliary power  15-second narrated native-window recording of the updated Probe Twin. The fan rotor starts from explicit simulated PS2 power, runs at an authored 8,300 RPM, and coasts to rest on shutdown. The visible 0.002× motion scale makes rotation inspectable. The housing and wires stay fixed; pause and backward seek preserve the expected rotor angle. **This is authored simulation, not measured fan response or cooling qualification.**