← Commit history

aiflow run board-codex-20261007-1749: thermal-vias

John Lauer ·0f87f2f95c ·16d ago ·parent a5a45e0
3 files changed +27−10
docs/runs/board-codex-20261007-1749/README.md+27−10
@@ -1,6 +1,6 @@ # AI Flow run: codex on board-0 -**Running**: step `routing`, 120.9 min of AI time since the prompt (1254.0 min on the wall clock). This page updates at every step change.+**Running**: step `thermal-vias`, 221.8 min of AI time since the prompt (1591.5 min on the wall clock). This page updates at every step change.  Prompt at 2026-10-07T17:49:14Z (UTC). Flow: board. Every number here is from the run's append-only ledger (run.jsonl). AI time is the time the AI was working on a prompt: from the human's prompt to the AI's done, with any gap over 15 min where no command ran (unobserved, not proven idle) cut out. @@ -13,8 +13,8 @@ One row per human prompt: the AI's time on it, unobserved gaps excluded by the h | 1 | 2026-10-07T17:49:14Z | (open) | 46.0 | 1019 | the first prompt | | 2 | 2026-10-08T11:34:31Z | (open) | 9.9 | 114 | User resumed custom electronic load work and reiterated recording clips for a YouTube buil | | 3 | 2026-10-08T13:38:16Z | (open) | 21.6 | 0 | Continue load design with fan tach and Kelvin-minus probe access; retain two-layer 3rdPart |-| 4 | 2026-10-08T13:59:54Z | (open) | 43.3 | 0 | Continue through remaining library, cooling, routing and recorded build work |-| **all** | | | **120.9** | | |+| 4 | 2026-10-08T13:59:54Z | (open) | 144.2 | 237 | Continue through remaining library, cooling, routing and recorded build work |+| **all** | | | **221.8** | | |  ## Per step @@ -24,14 +24,15 @@ AI time only, the idle cut out. |---|---|---|---|---|---|---|---| | intake | 2.6 | 0.3 | 2.2 | 3 | 1 | 0 | 0.3 min | | placement | 3.9 | 0.0 | 3.9 | 8 | 2 | 1 | 0.0 min |-| routing | 6.5 | 0.0 | 6.5 | 7 | 2 | 0 | 0.0 min |+| routing | 45.8 | 0.0 | 45.8 | 37 | 2 | 0 | 0.0 min | | components | 11.9 | 0.0 | 11.9 | 28 | 1 | 0 | 0.0 min | | design | 2.5 | 0.0 | 2.5 | 11 | 1 | 0 | 0.0 min | | libraries | 1.4 | 0.0 | 1.4 | 6 | 1 | 0 | 0.0 min | | models | 0.6 | 0.0 | 0.6 | 4 | 1 | 0 | 0.0 min |-| rules | 91.5 | 0.0 | 91.5 | 14 | 1 | 0 | 0.0 min |+| rules | 153.1 | 0.0 | 153.1 | 14 | 1 | 0 | 0.0 min | | test-plan | 0.1 | 0.0 | 0.1 | 5 | 1 | 0 | 0.0 min |-| **total** | **120.9** | **0.3** | **120.6** | | | | |+| thermal-vias | 0.0 | 0.0 | 0.0 | 1 | 1 | 0 | 0.0 min |+| **total** | **221.8** | **0.3** | **221.5** | | | | |  ## Returns to earlier steps @@ -50,9 +51,13 @@ AI time only, the idle cut out. - 2026-10-08T14:10:02Z capture-stop - 2026-10-08T14:39:33Z clip-start:placement-2 - 2026-10-08T14:41:14Z capture-stop+- 2026-10-08T14:51:51Z capture-stop  ## Where the board stands +- routing: 0 unrouted after null passes+- gate: 0 new DRC errors, 0 unconnected, null inherited+- landed live: 0 of 0 route entries  ## The steps on camera @@ -176,7 +181,19 @@ Why the AI came back here: Compact BOOST_SW loop and orient precision sense pins  What this step does: route to 100 percent with the spec's rules, gate with KiCad's DRC, land as undo steps; the AI takes it with take route=ai -**Clip: routing, visit 2, still recording (started 2026-10-08T14:43:13Z); it appears here when the step ends.**+**Clip: routing, visit 2, the PCB editor from 2026-10-08T14:43:13Z to 2026-10-08T14:51:51Z. Motion only: 8.6 min of real time, 16 s of it had something moving; the clock in the corner is the real elapsed time.**++<video width="100%" controls><source src="/blob/app/adom-custom-electronic-load/docs/runs/board-codex-20261007-1749/routing-2.mp4" type="video/mp4"></video>++**Contact sheet: nine frames spread through the routing, visit 2 clip, what the camera saw.**++![nine frames of routing, visit 2](/blob/app/adom-custom-electronic-load/docs/runs/board-codex-20261007-1749/routing-2-sheet.png)++### thermal-vias++What this step does: Heatsink vias where the heat is: for every part that dissipates real power (the regulator, the inductor, the catch diode, the FETs), an array of vias in its thermal pad or the copper it dumps heat into, stitched to the ground or the plane on the other side, sized and counted from its dissipation; the AI reviews the plan and the binary lands it.++**Clip: thermal-vias, still recording (started 2026-10-08T20:20:41Z); it appears here when the step ends.**  ## Plan usage, the second cost line @@ -184,10 +201,10 @@ Percent of each plan limit used, as the provider reports it, at the start of the  | Provider | Limit | At start | At end | Used by this run | |---|---|---|---|---|-| claude | 5h | 17 % | 8 % | -9.0 % |+| claude | 5h | 17 % | 3 % | -14.0 % | | claude | Fable | 0 % | 3 % | 3.0 % |-| claude | week | 54 % | 63 % | 9.0 % |-| codex | week | 2 % | 11 % | 9.0 % |+| claude | week | 54 % | 64 % | 10.0 % |+| codex | week | 2 % | 18 % | 16.0 % |  *The limits are per account, not per run: every AI thread signed in as this user draws on the same numbers, so a run made while other threads were working shows their usage too. Read it as an upper bound unless this run was the only thread active.* 
docs/runs/board-codex-20261007-1749/routing-2-sheet.pngadded
⋯ 1 unchanged line ⋯
docs/runs/board-codex-20261007-1749/routing-2.mp4added
⋯ 1 unchanged line ⋯