project
Adom Custom Electronic Load
Public Made by Adomby adom
Two-layer digitally controlled electronic-load prototype. Compact R11 is under active electrical, cooling and probe-access review; not a manufacturing release.
← Commit history
Add labeled corrected-current review clip and failed fine-mesh evidence
5 files changed
+105
design/hotspot-v27-review.jsonadded+88@@ -0,0 +1,88 @@+{+ "status": "isolated-candidate-not-landed",+ "boardSha256": "a365abb52e62eb33ef90f9e424f2a2851dfb81454c6ad65e794631663214ccb0",+ "nativeDRC": {+ "errors": 0,+ "unconnected": 0,+ "warnings": 0+ },+ "copperChanges": 44,+ "existingCopperNetChanges": 0,+ "footprintsMoved": [+ "Q2",+ "R7",+ "U3"+ ],+ "fieldsCandidatePR": "https://wiki.adom.inc/adom/adom-fields/prs/9",+ "sharedFieldsReplaced": false,+ "coarsePitchMm": 0.2,+ "coarseNets": [+ {+ "net": "DUT_POS",+ "peakJ": 48.27619934082031,+ "maximumMeanBarrelJ": 31.334569879117318+ },+ {+ "net": "LOAD_POS",+ "peakJ": 57.68394470214844,+ "maximumMeanBarrelJ": 26.445070309162837+ },+ {+ "net": "SHUNT_P",+ "peakJ": 59.6739501953125,+ "maximumMeanBarrelJ": 35.56608656235993+ },+ {+ "net": "GND",+ "peakJ": 50.701873779296875,+ "maximumMeanBarrelJ": 40.92413384875462+ },+ {+ "net": "DUT_FUSED",+ "peakJ": 45.19816589355469,+ "maximumMeanBarrelJ": 8.10460350305672+ },+ {+ "net": "5V_AUX",+ "peakJ": 18.182907104492188,+ "maximumMeanBarrelJ": 5.876490100056115+ }+ ],+ "fineMesh": "FAIL: all three screened nets exceed 60 A/mm2",+ "thermal": "unresolved; Q1 package heatsink path not modeled by planar board source",+ "aiflowVersion": "0.1.81",+ "aiflowSourceCommit": "dca0e3d047d9325cdd901c9ce02be1432ceb8287",+ "aiflowRegistryIntegrity": "sha256-c55ae5fc8b18bbde3f01ef3863e687d06d3d2ec29c8a9ea406fd28251197d879",+ "fineNets": [+ {+ "net": "LOAD_POS",+ "peakJ": 60.65583801269531,+ "peakAt": [+ 121.85,+ 90.45+ ],+ "peakLayer": "B.Cu",+ "residual": 9.852832860325988e-08+ },+ {+ "net": "GND",+ "peakJ": 72.94035339355469,+ "peakAt": [+ 139.25,+ 90.35000000000001+ ],+ "peakLayer": "F.Cu",+ "residual": 9.949823307316129e-08+ },+ {+ "net": "SHUNT_P",+ "peakJ": 70.55747985839844,+ "peakAt": [+ 133.75,+ 85.25+ ],+ "peakLayer": "B.Cu",+ "residual": 9.393389967428684e-08+ }+ ]+}
docs/build-clips.md+8@@ -148,3 +148,11 @@ Actual browser replay of the portable C controller and tach decoder with synthet Nine-second edit from three actual recordings: Pup access denial, the Native Browser verification surface, and review of the successful official Parts Search API result. Native evaluation returned underlying product text while the screenshot/video still showed verification; this is not claimed as successful visible access. The API result was obtained before its review recording. Static waits are removed; each segment runs at normal encoded speed. The raw recordings have timeline warnings, so they are not wall-clock measurements. Full decodes and contact-sheet reviews passed. The edited native segment crops network metadata. The raw inventory now contains 62 takes, including rejected/static clips. This is not 62 finished highlights.++## Corrected current-map review, 10 October++The new 21.3-second raw take walks the corrected 0.1 mm maps for ground, drain and shunt. Full decode and contact-sheet review passed. The labeled 17-second excerpt is a later engineering review of candidate v27, not original discovery, native construction or an accepted board. All three current screens remain open.++<video width="100%" playsinline controls preload="metadata" poster="docs/clips/corrected-current-review-poster.jpg" src="docs/clips/corrected-current-review.mp4"></video>++The raw inventory is now 70 takes, including rejected and static footage; that is not 70 final highlights.
docs/clips/corrected-current-review-poster.jpgadded⋯ 1 unchanged line ⋯
docs/clips/corrected-current-review.mp4added⋯ 1 unchanged line ⋯
videos/shotlog.json+9@@ -239,6 +239,15 @@ "topic": "AIFlow 0.1.70 status automatically opens Hydrogen dashboard", "status": "Native window recording reviewed; normal-speed excerpt decoded", "duration_s": 6.9+ },+ {+ "id": "corrected-current-review-70",+ "file": "raw/window-24324034-20261010-125642.mp4",+ "topic": "Corrected drill-void and plated-wall 0.1 mm current review",+ "status": "full decode and contact sheet reviewed; labeled candidate not accepted; editorial approval pending",+ "duration_s": 21.3,+ "recordingId": "rec-f51f55df64cd49759af22c91d9747387",+ "note": "Later review of candidate v27, not original solver discovery or live copper construction. GND, drain and shunt remain above current screen." } ], "failed_captures": [