  "status": "candidate current screen passes; thermal fails; not adopted",
  "inputIdentity": {
    "algorithm": "sha256",
    "board": "1681eb90e49f4f229afe89bb75ff1738b7503907a52cd174e8b3d64b120082f4",
    "solverVersion": "0.6.2",
    "spec": "06a2cd452aa7cb1f1b87fefd8c97f1595ca2073958f2739d1130da86cdd42735"
  },
  "fieldsSha256": "3be676b865b2278c8cf7539332ea80c519069ab6b2859be62fdc35eb5fbefbfc",
  "pitchMm": 0.1,
  "surfaceCopperUm": 35,
  "dielectricMm": 1.51,
  "surfaceAndBarrelLimit_A_mm2": 60,
  "nets": [
    {
      "net": "DUT_POS",
      "peakJ_A_mm2": 53.4538459777832,
      "residual": 9.853942391530799e-08,
      "peakBarrelJ_A_mm2": 31.32305238657173
    },
    {
      "net": "LOAD_POS",
      "peakJ_A_mm2": 40.08208084106445,
      "residual": 9.91818222374887e-08,
      "peakBarrelJ_A_mm2": 22.084072885900984
    },
    {
      "net": "GND",
      "peakJ_A_mm2": 58.13970947265625,
      "residual": 9.942328996737994e-08,
      "peakBarrelJ_A_mm2": 36.41305455001441
    },
    {
      "net": "SHUNT_P",
      "peakJ_A_mm2": 56.50440979003906,
      "residual": 8.97883447351078e-08,
      "peakBarrelJ_A_mm2": 33.85393111168713
    },
    {
      "net": "DUT_FUSED",
      "peakJ_A_mm2": 50.5965690612793,
      "residual": 9.730792094021261e-08,
      "peakBarrelJ_A_mm2": 11.509161945374204
    },
    {
      "net": "5V_AUX",
      "peakJ_A_mm2": 19.039779663085938,
      "residual": 9.139207627930405e-08,
      "peakBarrelJ_A_mm2": 5.876489753336553
    }
  ],
  "thermalIssues": [
    {
      "at": [
        115.12,
        91.0
      ],
      "fix": "More copper under the tab and more vias to the other layers, or a heatsink; moving air alone does not bring it in.",
      "kind": "tab-rise",
      "layer": "F.Cu",
      "net": "LOAD_POS",
      "reference": "D1",
      "severity": "high",
      "what": "D1: +138 \u00b0C at its thermal screening node in still air (+74 \u00b0C in moving air) against a 35 \u00b0C budget"
    },
    {
      "at": [
        127.46,
        82.0
      ],
      "fix": "More copper under the tab and more vias to the other layers, or a heatsink; moving air alone does not bring it in.",
      "kind": "tab-rise",
      "layer": "F.Cu",
      "net": "LOAD_POS",
      "reference": "Q1",
      "severity": "high",
      "what": "Q1: +593 \u00b0C at its thermal screening node in still air (+522 \u00b0C in moving air) against a 35 \u00b0C budget"
    },
    {
      "at": [
        136.625,
        85.7
      ],
      "fix": "More copper under the tab and more vias to the other layers, or a heatsink; moving air alone does not bring it in.",
      "kind": "tab-rise",
      "layer": "F.Cu",
      "net": "SHUNT_P",
      "reference": "RSH1",
      "severity": "high",
      "what": "RSH1: +140 \u00b0C at its thermal screening node in still air (+78 \u00b0C in moving air) against a 35 \u00b0C budget"
    }
  ],
  "limitations": [
    "Private reviewed solver; owner release pending.",
    "Finished surface and barrel copper require manufacturing confirmation.",
    "Board-only thermal model excludes the proposed case-mounted cooling path.",
    "Formal design/spec.json and PCB unchanged."
  ]
}