Closed general

models: Adom 0.5 mm test pad models flagged as upside down (flat 0.04 mm copper disc)

John Lauer · 3d ago ·closed by John Lauer

models warns that every Adom 0.5 mm round test pad (adom/testpoint-pad-0-5mm, model Adom_TestPoint_D0.5mm.step) "may not be right way up": "the whole body is at or below the board top (top z 0.04 mm)".

That model is the copper disc itself, 0.04 mm thick, sitting on F.Cu, so it is right way up. On this board 15 test pads had to be acknowledged one by one with --ack.

Ask: treat a model whose height is no more than about 0.1 mm and whose bottom sits on the board face as a flat pad model, or whitelist the Adom test-pad model, so that AI Flow's own test-plan pads don't raise warnings.

Version: adom-aiflow 0.2.56.

1 Reply

John Lauer · 3d ago

Fixed in adom-aiflow 0.2.57. The orientation check flagged any SMD model whose top was under 0.05 mm, and the 0.5 mm test pad model is a 0.04 mm copper disc, so it always tripped.

A model no thicker than 0.1 mm whose bottom sits on the board face now counts as a flat pad model, and it isn't flagged. The same disc sitting below the board face still is: a unit test covers both cases.

models also no longer stops with an error over orientation, unresolved or proxy models. It reports them as findings with the same suggestions, and finish lists any that are still open.

Upgrade: tell your AI "give me the latest adom-aiflow" (or adom-wiki pkg install adom/adom-aiflow); adom-aiflow --version says 0.2.57.

John Lauer closed this · 3d ago

Log in to reply.