← Commit history
docs/runs/source-unplaced-codex-astra-20260914-0314/README.md+23−4
@@ -1,6 +1,6 @@ # AI Flow run: Codex (Astra) on board-0 -**Running**: step `current`, 53.8 min since the prompt. This page updates at every step change.+**Running**: step `thermal`, 54.3 min since the prompt. This page updates at every step change.  Prompt at 2026-09-14T03:14:00.700Z (UTC). Flow: board. Every number here is from the run's append-only ledger (run.jsonl). @@ -12,10 +12,11 @@ Prompt at 2026-09-14T03:14:00.700Z (UTC). Flow: board. Every number here is from | placement | 6.4 | 5.6 | 0.8 | 16 | 3 | 2 | 2.0 min | | routing | 33.2 | 13.4 | 19.8 | 26 | 4 | 3 | 7.7 min | | pours | 9.8 | 3.0 | 6.8 | 20 | 2 | 1 | 1.0 min |-| current | 0.3 | 0.0 | 0.3 | 1 | 1 | 0 | 0.0 min |+| current | 0.8 | 0.4 | 0.4 | 2 | 1 | 0 | 0.4 min |+| thermal | 0.1 | 0.0 | 0.1 | 1 | 1 | 0 | 0.0 min | | capture | 0.8 | 0.0 | 0.8 | 1 | 0 | 0 | 0.0 min | | other | 0.0 | 0.0 | 0.0 | 1 | 0 | 0 | 0.0 min |-| **total** | **53.8** | **25.2** | **28.6** | | | | |+| **total** | **54.3** | **25.6** | **28.7** | | | | |  ## Returns to earlier steps @@ -48,6 +49,7 @@ Prompt at 2026-09-14T03:14:00.700Z (UTC). Flow: board. Every number here is from - 2026-09-14T04:03:14Z Outer GND pour preflight refused three starved thermal connections: MC18.1 on B.Cu, C36.2 and C9.2 on F.Cu. Add targeted solid joints at these pads; preserve clearance rules. - 2026-09-14T04:04:31Z Ground pour now passes; adding the battery region exposed one starved ground thermal at U1.1. Add a local solid ground joint and retry. - 2026-09-14T04:07:46Z clip-start:current-1+- 2026-09-14T04:08:18Z clip-start:thermal-1  ## Where the board stands @@ -56,6 +58,7 @@ Prompt at 2026-09-14T03:14:00.700Z (UTC). Flow: board. Every number here is from - landed live: 116 of 116 route entries - pours: 7 groups, failed [] - copper kept (mm2 per layer): {"B.Cu":3107.89,"F.Cu":2891.08,"In1.Cu":4129.04,"In2.Cu":3963.14}+- analyze-current: pass  ## The steps on camera @@ -223,12 +226,28 @@ Why the AI came back here: Routing is now fully landed with zero unconnected. Ad  What this step does: IPC-2221 on every loaded net, pour and via capacity, the same-layer rule -**Clip: current, still recording (started 2026-09-14T04:07:46Z); it appears here when the step ends.**+**Clip: current, the PCB editor from 2026-09-14T04:07:46Z to 2026-09-14T04:08:16Z, 0.5 min of real time shown at 10x (3 s).**++<video width="100%" controls><source src="/blob/app/adom-aiflow/docs/runs/source-unplaced-codex-astra-20260914-0314/current-1.mp4" type="video/mp4"></video>  **Screenshot: the board when current began.**  ![the board when current began](/blob/app/adom-aiflow/docs/runs/source-unplaced-codex-astra-20260914-0314/shot-current-1-start.png) +**Screenshot: the board when current ended.**++![the board when current ended](/blob/app/adom-aiflow/docs/runs/source-unplaced-codex-astra-20260914-0314/shot-current-1-end.png)++### thermal++What this step does: copper and vias at every hot tab against the rise budget++**Clip: thermal, still recording (started 2026-09-14T04:08:18Z); it appears here when the step ends.**++**Screenshot: the board when thermal began.**++![the board when thermal began](/blob/app/adom-aiflow/docs/runs/source-unplaced-codex-astra-20260914-0314/shot-thermal-1-start.png)+ ## Given back  5 issue(s) or PR(s) filed by this run's AI to make the tool better for every Adom user:
docs/runs/source-unplaced-codex-astra-20260914-0314/current-1.mp4added
⋯ 1 unchanged line ⋯
docs/runs/source-unplaced-codex-astra-20260914-0314/shot-current-1-end.pngadded
⋯ 1 unchanged line ⋯
docs/runs/source-unplaced-codex-astra-20260914-0314/shot-thermal-1-start.pngadded
⋯ 1 unchanged line ⋯