sourcing requires BOM rows for test pads marked exclude_from_bom; rotation check stops on EasyEDA 403

Sven Claar · ·closed by Colby Knox

sourcing counts test pads marked exclude_from_bom

adom-aiflow-jlcpcb (installed 2026-11-20), sourcing.

Bare 0.5 mm test pads (TP1..TP7, footprint attribute exclude_from_bom exclude_from_pos_files) are listed as "board references with no BOM row" when the BOM leaves them out, and as "no LCSC number (no part)" when the BOM keeps a no part row. Sourcing cannot close either way. The JLCPCB CPL export already leaves them out correctly.

Expected: board references whose footprint is excluded from the BOM (or DNP) are not required in the sourcing BOM.

Also seen: the rotation check stops on the first EasyEDA 403 (easyeda.com/api/products/<LCSC>/components blocked from the container), so every part ends retrieval-unverified; a retry through the desktop (Adom Bridge) would reach it.

1 Reply

Colby Knox marked this in progress ·
Colby Knox mentioned this in pull request #5 ·
Colby Knox ·

Thanks Sven, both fixed in adom-aiflow-jlcpcb 0.1.7.

  • Test pads in sourcing: a footprint marked exclude_from_bom or board_only, or not fitted (DNP), no longer needs a BOM row, and a "no part" row for one is no longer asked for an LCSC number. Sourcing now closes for your TP1 to TP7, matching what the CPL already did.
  • The EasyEDA 403: EasyEDA refuses the automated browser. When that happens, the rotation check now looks once for a browser profile on the same desktop with the Adom extension running, and reads the remaining footprints there. If there isn't one, the message says that adding the extension to your browser is the fix. --browser-target/--browser-profile still pick a profile yourself.

To upgrade: adom-wiki pkg install adom/adom-aiflow-jlcpcb, then adom-aiflow-jlcpcb --version should say 0.1.7. If sourcing or the rotation check still stops on either, reopen this issue.

Colby Knox removed the in progress marker ·
Colby Knox closed this ·