Rotation check: repeated pads, vendor vs KiCad pad numbering, alternate land patterns
Split out of #1 (John Lauer, 2026-10-19). #1's own fix, keeping vendor access failures as failed verification, shipped in 0.1.1.
What's left. On the five-board electronic-load quote, full EasyEDA retrieval gave twelve pad-fit discrepancies. One was a real stale BOM identity (J10), since fixed. The other eleven are probably cases the rotation check can't tell apart from a wrong footprint:
- Repeated physical pads. Several pads share a number: thermal pads split into a grid, or mounting tabs.
- Vendor versus electrical terminal numbering. EasyEDA's pad numbers aren't KiCad's, for example a connector's shield or mechanical pads.
- Alternate land patterns. The vendor footprint is a valid alternative land with different pad dimensions, so the centres don't line up exactly.
Today rotation (src/rotation.rs, about line 214) fails every such part with "review terminal numbering, repeated pads, land dimensions, footprint identity and orientation". That's correct but unspecific, so all eleven need a manual drawing review.
Wanted. Checker support for each case that still never relaxes the tolerance:
- match repeated pads as a set;
- map vendor to KiCad numbering, from an explicit per-part mapping or by matching pad geometry, and record which;
- say when a land is a dimensionally different alternative, not a rotation error.
Each part's result should say which case applied. Anything still unexplained stays a failure for manufacturer-drawing review.
Done when: the electronic-load board's eleven remaining parts are each classified (fits after the case is handled, or a real mismatch), with tests for each case and no tolerance change.
1 Reply