← Commit history

Set visibility: public

Ray ·a2cbb470c8 ·1mo ago ·parent 37a8764
1 file changed +6−3
page.json+6−3
@@ -38,13 +38,13 @@         "number": "2",         "name": "/RESET",         "type": "output",-        "description": "Active-low, open-drain reset output. /RESET remains low while VCC is below the reset threshold (3.08 V typ for the T option) and remains low for 240 ms (typical) after VCC rises above the reset threshold. Requires an external pull-up resistor (open-drain output leakage 1 \u00b5A max, sink capability 1.2 mA at 0.3 V / 3.2 mA at 0.4 V)."+        "description": "Active-low, open-drain reset output. /RESET remains low while VCC is below the reset threshold (3.08 V typ for the T option) and remains low for 240 ms (typical) after VCC rises above the reset threshold. Requires an external pull-up resistor (open-drain output leakage 1 µA max, sink capability 1.2 mA at 0.3 V / 3.2 mA at 0.4 V)."       },       {         "number": "3",         "name": "VCC",         "type": "power_in",-        "description": "Supply voltage being monitored. Operating range 1.0 V to 5.5 V (1.2 V to 5.5 V over full temp). Reset threshold for the -T option is 3.08 V typ (3.04 V to 3.11 V at 25\u00b0C). Supply current 17 \u00b5A typ."+        "description": "Supply voltage being monitored. Operating range 1.0 V to 5.5 V (1.2 V to 5.5 V over full temp). Reset threshold for the -T option is 3.08 V typ (3.04 V to 3.11 V at 25°C). Supply current 17 µA typ."       }     ],     "provenance": {@@ -122,5 +122,8 @@     "docs/adm803taksz-reel7-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file