← Commit history

Set visibility: public

Ray ·61e8abbcc4 ·29d ago ·parent b61cdfe
1 file changed +8−5
page.json+8−5
@@ -32,7 +32,7 @@         "number": "1",         "name": "IP+",         "type": "passive",-        "description": "Primary current input terminal. Terminals for the current being sensed; fused internally with pin 2. The IP+ and IP\u2212 pairs form the isolated copper conduction path with ~1.2 m\u03a9 resistance in the LC package."+        "description": "Primary current input terminal. Terminals for the current being sensed; fused internally with pin 2. The IP+ and IP− pairs form the isolated copper conduction path with ~1.2 mΩ resistance in the LC package."       },       {         "number": "2",@@ -62,19 +62,19 @@         "number": "6",         "name": "FAULT",         "type": "output",-        "description": "Overcurrent fault output; active-low, open-drain style requiring an external pull-up (RPU \u2265 1 k\u03a9). Latches low when |IP| exceeds IFAULT (\u00b11\u00d7 full-scale); reset only by cycling VCC below VCCFR (200 mV) for at least tCCFR (100 \u03bcs). VFAULT rated 7 V max."+        "description": "Overcurrent fault output; active-low, open-drain style requiring an external pull-up (RPU ≥ 1 kΩ). Latches low when |IP| exceeds IFAULT (±1× full-scale); reset only by cycling VCC below VCCFR (200 mV) for at least tCCFR (100 μs). VFAULT rated 7 V max."       },       {         "number": "7",         "name": "VIOUT",         "type": "output",-        "description": "Analog output signal. Ratiometric to VCC with quiescent output VCC/2 at IP = 0 A; sensitivity 55 mV/A for the x25AB variant. Bandwidth 100 kHz; drives loads \u226515 k\u03a9 and \u22641 nF."+        "description": "Analog output signal. Ratiometric to VCC with quiescent output VCC/2 at IP = 0 A; sensitivity 55 mV/A for the x25AB variant. Bandwidth 100 kHz; drives loads ≥15 kΩ and ≤1 nF."       },       {         "number": "8",         "name": "VCC",         "type": "power_in",-        "description": "Device power supply terminal. 3 to 5.5 V single supply (3.3 V nominal for factory-trimmed accuracy); ICC \u2248 4 mA typical. Bypass with 0.1 \u03bcF to GND. Absolute max 7 V."+        "description": "Device power supply terminal. 3 to 5.5 V single supply (3.3 V nominal for factory-trimmed accuracy); ICC ≈ 4 mA typical. Bypass with 0.1 μF to GND. Absolute max 7 V."       }     ],     "provenance": {@@ -172,5 +172,8 @@     "docs/acs711klctr-25ab-t-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file