← Commit history
page.json+7−4@@ -38,13 +38,13 @@ "number": "2", "name": "CLK", "type": "input",- "description": "Serial Data Clock. Synchronizes master-to-slave communication. Opcodes, address and data bits are latched on the rising edge; data is clocked out on the rising edge. Max FCLK = 3 MHz at VCC \u2265 4.5 V (2 MHz at VCC \u2265 2.5 V)."+ "description": "Serial Data Clock. Synchronizes master-to-slave communication. Opcodes, address and data bits are latched on the rising edge; data is clocked out on the rising edge. Max FCLK = 3 MHz at VCC ≥ 4.5 V (2 MHz at VCC ≥ 2.5 V)." }, { "number": "3", "name": "DI", "type": "input",- "description": "Serial Data Input. Clocks in the Start bit, opcode, address and write data synchronously with CLK. VIH \u2265 2.0 V (VCC \u2265 2.7 V) or 0.7\u00b7VCC (VCC < 2.7 V)."+ "description": "Serial Data Input. Clocks in the Start bit, opcode, address and write data synchronously with CLK. VIH ≥ 2.0 V (VCC ≥ 2.7 V) or 0.7·VCC (VCC < 2.7 V)." }, { "number": "4",@@ -74,7 +74,7 @@ "number": "8", "name": "VCC", "type": "power_in",- "description": "Power supply, 2.5 V to 5.5 V for 93LC-family (industrial temp). Typical read current 500 \u00b5A @ 3.0 V / 2 MHz; standby current typ. 1 \u00b5A (I-temp). Decouple with a 0.1 \u00b5F capacitor to VSS."+ "description": "Power supply, 2.5 V to 5.5 V for 93LC-family (industrial temp). Typical read current 500 µA @ 3.0 V / 2 MHz; standby current typ. 1 µA (I-temp). Decouple with a 0.1 µF capacitor to VSS." } ], "provenance": {@@ -138,5 +138,8 @@ "docs/93lc46bt-i-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }