← Commit history
page.json+8−5@@ -38,25 +38,25 @@ "number": "2", "name": "A", "type": "input",- "description": "Schmitt-trigger data input. Accepts signals up to 5.5 V regardless of VCC. Typical hysteresis (VT+ - VT-) is ~0.35 V at VCC = 3 V; VT+ ranges 1.50-2.00 V and VT- ranges 0.80-1.30 V at VCC = 3 V. Input current II is \u00b15 \u00b5A max."+ "description": "Schmitt-trigger data input. Accepts signals up to 5.5 V regardless of VCC. Typical hysteresis (VT+ - VT-) is ~0.35 V at VCC = 3 V; VT+ ranges 1.50-2.00 V and VT- ranges 0.80-1.30 V at VCC = 3 V. Input current II is ±5 µA max." }, { "number": "3", "name": "GND", "type": "power_in",- "description": "Device ground reference (0 V). Continuous current through GND is limited to \u00b1100 mA absolute maximum."+ "description": "Device ground reference (0 V). Continuous current through GND is limited to ±100 mA absolute maximum." }, { "number": "4", "name": "Y", "type": "output",- "description": "Push-pull inverting data output (Y = /A). Drive capability is \u00b124 mA at VCC = 3 V; continuous output current IO is limited to \u00b150 mA absolute maximum. High-impedance and IOFF-isolated when VCC is powered down."+ "description": "Push-pull inverting data output (Y = /A). Drive capability is ±24 mA at VCC = 3 V; continuous output current IO is limited to ±50 mA absolute maximum. High-impedance and IOFF-isolated when VCC is powered down." }, { "number": "5", "name": "VCC", "type": "power_in",- "description": "Supply voltage input. Recommended operating range 1.65 V to 5.5 V (1.5 V min for data retention only). Absolute maximum -0.5 V to 6.5 V. Typical ICC is 10 \u00b5A max at TA \u2264 85 \u00b0C."+ "description": "Supply voltage input. Recommended operating range 1.65 V to 5.5 V (1.5 V min for data retention only). Absolute maximum -0.5 V to 6.5 V. Typical ICC is 10 µA max at TA ≤ 85 °C." } ], "provenance": {@@ -120,5 +120,8 @@ "docs/74lvc1g14se-7-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }