Initial commit: component/4532-601-lf

Ray ·8b1253beaf ·6d ago
2 files changed +145
README.mdadded+38
@@ -0,0 +1,38 @@+# 4532-601-LF++**Brightking** · Gas Discharge Tube Arresters (GDT) · 1812++4532-601-LF from Brightking, in a 1812. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model); symbol, footprint, and 3D from KiCad-official CAD.++## Pinout++| Pin | Name | Type | Function |+|---|---|---|---|+| 1 | 1 | passive | First electrode of the non-polarized gas discharge tube, with DC spark-over voltage 420~780 V at 100 V/s, maximum impulse spark-over 1200 V at 1 kV/µs, and 2000 A 8/20µs nominal impulse discharge current, measured between the two electrodes. |+| 2 | 2 | passive | Second electrode of the non-polarized gas discharge tube, with DC spark-over voltage 420~780 V at 100 V/s, maximum impulse spark-over 1200 V at 1 kV/µs, and 2000 A 8/20µs nominal impulse discharge current, measured between the two electrodes. |++## Key specifications++| Parameter | Value |+|---|---|+| Manufacturer | Brightking |+| Package | 1812 |+| Category | Circuit Protection |+| Pins | 2 |++## CAD (KiCad official)++- Symbol: `4532-601-LF`+- Footprint: `Resistor_SMD:R_1812_4532Metric`+- 3D model: 1812 (KiCad packages3D, STEP)+- 3D model files: `4532-601-lf-etched.step` / `4532-601-lf-etched.glb` carry the MPN laser-etched on the die in a toggleable `Adom.LaserEtch` group (Fusion-ready); `4532-601-lf.step` / `4532-601-lf.glb` are the bare package body.++## Provenance++Data extracted from the manufacturer datasheet, not a distributor listing:++- **Datasheet:** [Brightking datasheet](https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8588884004715683840) (4 pp, sha256 `c56bf5479a375e3b`, retrieved 2026-09-29, tier: lcsc)+- **Extractor:** `ds2sf` (Claude). Every pin and dimension is cited to a datasheet page; it refuses to fabricate.+- **CAD:** KiCad official libraries (CC-BY-SA 4.0).++[Datasheet PDF](docs/4532-601-lf-datasheet.pdf)
page.jsonadded+107
@@ -0,0 +1,107 @@+{+  "slug": "4532-601-lf",+  "version": "0.1.0",+  "type": "component",+  "description": "Brightking Gas Discharge Tube Arresters (GDT), 1812. Pinout reviewed by a person against the datasheet, KiCad symbol/footprint/3D.",+  "tags": [+    "component",+    "circuit protection",+    "4532-601-lf",+    "factory-2.0.0",+    "extractor-text"+  ],+  "dependencies": {},+  "hero": {+    "type": "image",+    "path": "docs/hero.png"+  },+  "files": [+    "page.json",+    "README.md",+    "4532-601-lf.kicad_sym",+    "4532-601-lf.kicad_mod",+    "4532-601-lf.glb",+    "4532-601-lf.step",+    "4532-601-lf.lbr",+    "docs/hero.png",+    "docs/4532-601-lf-datasheet.pdf",+    "viewers/symbol.html",+    "viewers/footprint.html"+  ],+  "component": {+    "mpn": "4532-601-LF",+    "manufacturer": "Brightking",+    "package": "1812",+    "pin_count": 2,+    "category": "Circuit Protection",+    "subcategory": "Gas Discharge Tube Arresters (GDT)",+    "datasheet": "https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8588884004715683840",+    "parts": {+      "symbol": "4532-601-lf.kicad_sym",+      "footprint": "4532-601-lf.kicad_mod",+      "model_3d": "4532-601-lf-etched.glb",+      "model_3d_plain": "4532-601-lf.glb",+      "model_3d_step": "4532-601-lf-etched.step",+      "model_3d_step_plain": "4532-601-lf.step",+      "lbr": "4532-601-lf.lbr"+    },+    "distributor_links": {+      "lcsc": "C96422",+      "digikey": "13-4532-601-LFTR-ND",+      "mouser": "603-4532-601-LF"+    },+    "distributor_check": {+      "checked_at": "2026-09-29T15:33:09Z",+      "source": "Component Ocean /api/assign-pns",+      "digikey": {+        "pn": "13-4532-601-LFTR-ND",+        "status": "found",+        "lifecycle": "Active"+      },+      "mouser": {+        "pn": "603-4532-601-LF",+        "status": "found"+      }+    },+    "pins": [+      {+        "number": "1",+        "name": "1",+        "type": "passive",+        "description": "First electrode of the non-polarized gas discharge tube, with DC spark-over voltage 420~780 V at 100 V/s, maximum impulse spark-over 1200 V at 1 kV/µs, and 2000 A 8/20µs nominal impulse discharge current, measured between the two electrodes."+      },+      {+        "number": "2",+        "name": "2",+        "type": "passive",+        "description": "Second electrode of the non-polarized gas discharge tube, with DC spark-over voltage 420~780 V at 100 V/s, maximum impulse spark-over 1200 V at 1 kV/µs, and 2000 A 8/20µs nominal impulse discharge current, measured between the two electrodes."+      }+    ],+    "provenance": {+      "extractor": "ds2sf",+      "datasheet": {+        "url": "https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8588884004715683840",+        "pages": 4,+        "sha256": "c56bf5479a375e3b",+        "source_tier": "lcsc"+      },+      "cad": "KiCad official (CC-BY-SA 4.0)",+      "pins": {+        "total": 2,+        "described": 2,+        "cites_pages": true,+        "refuses_to_fabricate": true+      }+    },+    "viewers": {+      "symbol": "viewers/symbol.html",+      "footprint": "viewers/footprint.html"+    }+  },+  "visibility": "public",+  "org": "adom",+  "author": {+    "name": "Ray",+    "email": "[email protected]"+  }+}\ No newline at end of file