← Commit history

34 members (walsin, yageo)

Ray ·3964dc1e77 ·16h ago ·parent e71a7ad
2 files changed +39−8
README.md+28−5
@@ -1,15 +1,33 @@ # 220pF 1206 Capacitors -**26 MLCCs** from Yageo. Parts within a section are interchangeable.+**34 MLCCs** from Walsin, Yageo. Parts within a section are interchangeable.  CAD: [1206 capacitor](/adom/1206-capacitor-cad) — one footprint, symbol and 3D model for every part here. +## C0G, 500V, ±5% (1)++| MPN | Manufacturer | Series | Datasheet | Stock |+|---|---|---|---|---|+| `1206N221J501CT` | Walsin | [1206N](/adom/walsin-1206n-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2401181654_Walsin-Tech-Corp-1206N221J501CT_C3864574.pdf) (lcsc) | 1,940 |++## C0G, 630V, ±10% (1)++| MPN | Manufacturer | Series | Datasheet | Stock |+|---|---|---|---|---|+| `1206N221K631CT` | Walsin | [1206N](/adom/walsin-1206n-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2401181710_Walsin-Tech-Corp-1206N221K631CT_C3908696.pdf) (lcsc) | 720 |+ ## C0G, 1kV, ±5% (1)  | MPN | Manufacturer | Series | Datasheet | Stock | |---|---|---|---|---| | `AC1206JKNPOCBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 471 | +## C0G, 2kV, tolerance n/s (1)++| MPN | Manufacturer | Series | Datasheet | Stock |+|---|---|---|---|---|+| `1206N221J202CT` | Walsin | [1206N](/adom/walsin-1206n-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2401181608_Walsin-Tech-Corp-1206N221J202CT_C3851120.pdf) (lcsc) | 1,258 |+ ## NP0, 50V, ±1% (1)  | MPN | Manufacturer | Series | Datasheet | Stock |@@ -75,11 +93,12 @@ CAD: [1206 capacitor](/adom/1206-capacitor-cad) — one footprint, symbol and 3D | `CC1206JKNPOZBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 1,834 | | `AC1206JKNPOZBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 127 | -## NP0, 1kV, ±5% (2)+## NP0, 1kV, ±5% (3)  | MPN | Manufacturer | Series | Datasheet | Stock | |---|---|---|---|---| | `CC1206JKNPOCBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 51,230 |+| `1206N221J102CT` | Walsin | [1206N](/adom/walsin-1206n-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2304140030_Walsin-Tech-Corp-1206N221J102CT_C384723.pdf) (lcsc) | 745 | | `CS1206JKNPOCBN221` | Yageo | [CS120](/adom/yageo-cs120-series) | — | 39 |  ## NP0, 2kV, ±5% (1)@@ -106,11 +125,13 @@ CAD: [1206 capacitor](/adom/1206-capacitor-cad) — one footprint, symbol and 3D |---|---|---|---|---| | `CC1206KRX7RABB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 5,228 | -## X7R, 500V, ±10% (1)+## X7R, 500V, ±10% (3)  | MPN | Manufacturer | Series | Datasheet | Stock | |---|---|---|---|---| | `CC1206KKX7RBBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 6,193 |+| `1206B221K501CT` | Walsin | [1206B](/adom/walsin-1206b-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2309201537_Walsin-Tech-Corp-1206B221K501CT_C3880825.pdf) (lcsc) | 36 |+| `1206B221K501` | Walsin | [1206B](/adom/walsin-1206b-series) | [LCSC mirror](https://www.lcsc.com/datasheet/lcsc_datasheet_2304140030_Walsin-Tech-Corp-1206B221K501_C152970.pdf) (lcsc) | 16 |  ## X7R, 630V, ±10% (1) @@ -118,14 +139,16 @@ CAD: [1206 capacitor](/adom/1206-capacitor-cad) — one footprint, symbol and 3D |---|---|---|---|---| | `CC1206KKX7RZBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 1,509 | -## X7R, 1kV, ±10% (1)+## X7R, 1kV, ±10% (2)  | MPN | Manufacturer | Series | Datasheet | Stock | |---|---|---|---|---| | `CC1206KKX7RCBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 44,731 |+| `1206B221K102CT` | Walsin | [1206B](/adom/walsin-1206b-series) | — | 6,264 | -## X7R, 2kV, ±10% (1)+## X7R, 2kV, ±10% (2)  | MPN | Manufacturer | Series | Datasheet | Stock | |---|---|---|---|---|+| `1206B221K202CT` | Walsin | [1206B](/adom/walsin-1206b-series) | — | 2,142 | | `CC1206KKX7RDBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 390 |
page.json+11−3
@@ -5,8 +5,8 @@   "kind": "group",   "version": "0.1.0",   "title": "220pF 1206 Capacitors",-  "brief": "26 interchangeable 220pF 1206 MLCCs.",-  "readme": "# 220pF 1206 Capacitors\n\n**26 MLCCs** from Yageo. Parts within a section are interchangeable.\n\nCAD: [1206 capacitor](/adom/1206-capacitor-cad) — one footprint, symbol and 3D model for every part here.\n\n## C0G, 1kV, ±5% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `AC1206JKNPOCBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 471 |\n\n## NP0, 50V, ±1% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206FRNPO9BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 129 |\n\n## NP0, 50V, ±2% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206GRNPO9BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 1,238 |\n\n## NP0, 50V, ±5% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JRNPO9BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 22,942 |\n| `AC1206JRNPO9BN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 233 |\n\n## NP0, 50V, ±10% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRNPO9BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 4,000 |\n\n## NP0, 100V, ±5% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JRNPO0BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 677 |\n| `AC1206JRNPO0BN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 19 |\n\n## NP0, 200V, ±5% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JRNPOABN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 5,138 |\n\n## NP0, 250V, ±5% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JRNPOYBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 738 |\n| `AC1206JRNPOYBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 560 |\n\n## NP0, 500V, ±5% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `AC1206JRNPOBBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 1,640 |\n| `CC1206JRNPOBBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 538 |\n\n## NP0, 500V, ±10% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRNPOBBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 6 |\n\n## NP0, 630V, ±5% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JKNPOZBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 1,834 |\n| `AC1206JKNPOZBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 127 |\n\n## NP0, 1kV, ±5% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JKNPOCBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 51,230 |\n| `CS1206JKNPOCBN221` | Yageo | [CS120](/adom/yageo-cs120-series) | — | 39 |\n\n## NP0, 2kV, ±5% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JKNPODBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | — | 2,862 |\n\n## X7R, 50V, ±10% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRX7R9BB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 2,019 |\n\n## X7R, 100V, ±10% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRX7R0BB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 17 |\n\n## X7R, 200V, ±10% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRX7RABB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 5,228 |\n\n## X7R, 500V, ±10% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KKX7RBBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 6,193 |\n\n## X7R, 630V, ±10% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KKX7RZBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 1,509 |\n\n## X7R, 1kV, ±10% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KKX7RCBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 44,731 |\n\n## X7R, 2kV, ±10% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KKX7RDBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 390 |\n",+  "brief": "34 interchangeable 220pF 1206 MLCCs.",+  "readme": "# 220pF 1206 Capacitors\n\n**34 MLCCs** from Walsin, Yageo. Parts within a section are interchangeable.\n\nCAD: [1206 capacitor](/adom/1206-capacitor-cad) \u2014 one footprint, symbol and 3D model for every part here.\n\n## C0G, 500V, \u00b15% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `1206N221J501CT` | Walsin | [1206N](/adom/walsin-1206n-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2401181654_Walsin-Tech-Corp-1206N221J501CT_C3864574.pdf) (lcsc) | 1,940 |\n\n## C0G, 630V, \u00b110% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `1206N221K631CT` | Walsin | [1206N](/adom/walsin-1206n-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2401181710_Walsin-Tech-Corp-1206N221K631CT_C3908696.pdf) (lcsc) | 720 |\n\n## C0G, 1kV, \u00b15% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `AC1206JKNPOCBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 471 |\n\n## C0G, 2kV, tolerance n/s (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `1206N221J202CT` | Walsin | [1206N](/adom/walsin-1206n-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2401181608_Walsin-Tech-Corp-1206N221J202CT_C3851120.pdf) (lcsc) | 1,258 |\n\n## NP0, 50V, \u00b11% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206FRNPO9BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 129 |\n\n## NP0, 50V, \u00b12% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206GRNPO9BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 1,238 |\n\n## NP0, 50V, \u00b15% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JRNPO9BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 22,942 |\n| `AC1206JRNPO9BN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 233 |\n\n## NP0, 50V, \u00b110% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRNPO9BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 4,000 |\n\n## NP0, 100V, \u00b15% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JRNPO0BN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 677 |\n| `AC1206JRNPO0BN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 19 |\n\n## NP0, 200V, \u00b15% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JRNPOABN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 5,138 |\n\n## NP0, 250V, \u00b15% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JRNPOYBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 738 |\n| `AC1206JRNPOYBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 560 |\n\n## NP0, 500V, \u00b15% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `AC1206JRNPOBBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 1,640 |\n| `CC1206JRNPOBBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 538 |\n\n## NP0, 500V, \u00b110% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRNPOBBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 6 |\n\n## NP0, 630V, \u00b15% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JKNPOZBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 1,834 |\n| `AC1206JKNPOZBN221` | Yageo | [AC120](/adom/yageo-ac120-series) | [datasheet](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 127 |\n\n## NP0, 1kV, \u00b15% (3)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JKNPOCBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 51,230 |\n| `1206N221J102CT` | Walsin | [1206N](/adom/walsin-1206n-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2304140030_Walsin-Tech-Corp-1206N221J102CT_C384723.pdf) (lcsc) | 745 |\n| `CS1206JKNPOCBN221` | Yageo | [CS120](/adom/yageo-cs120-series) | \u2014 | 39 |\n\n## NP0, 2kV, \u00b15% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206JKNPODBN221` | Yageo | [CC120](/adom/yageo-cc120-series) | \u2014 | 2,862 |\n\n## X7R, 50V, \u00b110% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRX7R9BB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 2,019 |\n\n## X7R, 100V, \u00b110% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRX7R0BB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 17 |\n\n## X7R, 200V, \u00b110% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KRX7RABB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 5,228 |\n\n## X7R, 500V, \u00b110% (3)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KKX7RBBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 6,193 |\n| `1206B221K501CT` | Walsin | [1206B](/adom/walsin-1206b-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2309201537_Walsin-Tech-Corp-1206B221K501CT_C3880825.pdf) (lcsc) | 36 |\n| `1206B221K501` | Walsin | [1206B](/adom/walsin-1206b-series) | [LCSC mirror](https://www.lcsc.com/datasheet/lcsc_datasheet_2304140030_Walsin-Tech-Corp-1206B221K501_C152970.pdf) (lcsc) | 16 |\n\n## X7R, 630V, \u00b110% (1)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KKX7RZBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 1,509 |\n\n## X7R, 1kV, \u00b110% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `CC1206KKX7RCBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 44,731 |\n| `1206B221K102CT` | Walsin | [1206B](/adom/walsin-1206b-series) | \u2014 | 6,264 |\n\n## X7R, 2kV, \u00b110% (2)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `1206B221K202CT` | Walsin | [1206B](/adom/walsin-1206b-series) | \u2014 | 2,142 |\n| `CC1206KKX7RDBB221` | Yageo | [CC120](/adom/yageo-cc120-series) | [CC X7R family](https://yageogroup.com/content/datasheet/asset/file/UPY-GPHC_X7R_6_3V-TO-250V) (mfr) | 390 |\n",   "tags": [     "passives-2026-10",     "tier:class",@@ -31,8 +31,16 @@     "distributor_links": {},     "group": {       "tier": "class",-      "member_count": 26,+      "member_count": 34,       "members": [+        "1206B221K102CT",+        "1206B221K202CT",+        "1206B221K501",+        "1206B221K501CT",+        "1206N221J102CT",+        "1206N221J202CT",+        "1206N221J501CT",+        "1206N221K631CT",         "AC1206JKNPOCBN221",         "AC1206JKNPOZBN221",         "AC1206JRNPO0BN221",