← Commit history

19 members (uniroyal, yageo)

Ray ·878e809fe7 · ·parent 1aa027b
2 files changed +38−25
README.md+24−18
@@ -1,38 +1,44 @@ # 200kΩ 1206 Resistors -**13 MPNs** from **1** manufacturer(s). Parts within a section are interchangeable.+**19 MPNs** from Uniroyal, Yageo. Parts within a section are interchangeable.  CAD: [1206 resistor](/adom/1206-resistor-cad) — one footprint, symbol and 3D model shared by every part here. -## ±0.1%, 250mW (3 MPNs)+## ±0.1%, 250mW (4 MPNs)  | MPN | Manufacturer | Series | Datasheet | Stock | |---|---|---|---|---|-| `RT1206BRD07200KL` | YAGEO | [RT120](/adom/yageo-rt120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) | 68,269 |-| `AT1206BRD07200KL` | YAGEO | [AT12](/adom/yageo-at12-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-AT_51_ROHS_L) | 4,474 |-| `RT1206BRE07200KL` | YAGEO | [RT120](/adom/yageo-rt120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) | 5 |+| `RT1206BRD07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 68,269 |+| `TC0650B2003T5J` | Uniroyal | [TC06](/adom/uniroyal-tc06-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2208170930_UNI-ROYAL-Uniroyal-Elec-TC0650B2003T5J_C2989381.pdf) (lcsc) | 29,535 |+| `AT1206BRD07200KL` | Yageo | [AT12](/adom/yageo-at12-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-AT_51_ROHS_L) (mfr) | 4,474 |+| `RT1206BRE07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 5 | -## ±0.5%, 250mW (2 MPNs)+## ±0.5%, 250mW (3 MPNs)  | MPN | Manufacturer | Series | Datasheet | Stock | |---|---|---|---|---|-| `RT1206DRD07200KL` | YAGEO | [RT120](/adom/yageo-rt120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) | 5,175 |-| `RT1206DRE07200KL` | YAGEO | [RT120](/adom/yageo-rt120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) | 40 |+| `RT1206DRD07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 5,175 |+| `RT1206DRE07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 40 |+| `TC0625D2003T5J` | Uniroyal | [TC06](/adom/uniroyal-tc06-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2208170930_UNI-ROYAL-Uniroyal-Elec-TC0625D2003T5J_C2988899.pdf) (lcsc) | 15 | -## ±1%, 250mW (5 MPNs)+## ±1%, 250mW (7 MPNs)  | MPN | Manufacturer | Series | Datasheet | Stock | |---|---|---|---|---|-| `RC1206FR-07200KL` | YAGEO | [RC120](/adom/yageo-rc120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-RC_GROUP_51_ROHS_L) | 177,506 |-| `AC1206FR-07200KL` | YAGEO | [AC120](/adom/yageo-ac120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) | 30,779 |-| `RT1206FRE07200KL` | YAGEO | [RT120](/adom/yageo-rt120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) | 5,100 |-| `RV1206FR-07200KL` | YAGEO | [RV12](/adom/yageo-rv12-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-RV_51_ROHS_L) | 277 |-| `AF1206FR-07200KL` | YAGEO | [AF120](/adom/yageo-af120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-AF_51_ROHS_L) | 14 |+| `RC1206FR-07200KL` | Yageo | [RC120](/adom/yageo-rc120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RC_GROUP_51_ROHS_L) (mfr) | 177,506 |+| `AC1206FR-07200KL` | Yageo | [AC120](/adom/yageo-ac120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 30,779 |+| `RT1206FRE07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 5,100 |+| `1206W4F2003T5E` | Uniroyal | [1206W4](/adom/uniroyal-1206w4-series) | [General purpose](https://www.royalohm.com/assets/pdf/products/smd/1.pdf) (mfr) | 373 |+| `RV1206FR-07200KL` | Yageo | [RV12](/adom/yageo-rv12-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RV_51_ROHS_L) (mfr) | 277 |+| `HV06W4F2003T5E` | Uniroyal | [HV06](/adom/uniroyal-hv06-series) | [High voltage HV](https://www.royalohm.com/assets/pdf/products/smd/7.pdf) (mfr) | 228 |+| `AF1206FR-07200KL` | Yageo | [AF120](/adom/yageo-af120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-AF_51_ROHS_L) (mfr) | 14 | -## ±5%, 250mW (3 MPNs)+## ±5%, 250mW (5 MPNs)  | MPN | Manufacturer | Series | Datasheet | Stock | |---|---|---|---|---|-| `RC1206JR-07200KL` | YAGEO | [RC120](/adom/yageo-rc120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-RC_GROUP_51_ROHS_L) | 32,604 |-| `AC1206JR-07200KL` | YAGEO | [AC120](/adom/yageo-ac120-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) | 5,675 |-| `RV1206JR-07200KL` | YAGEO | [RV12](/adom/yageo-rv12-series) | [mfr](https://yageogroup.com/content/datasheet/asset/file/PYU-RV_51_ROHS_L) | 2,626 |+| `1206W4J0204T5E` | Uniroyal | [1206W4](/adom/uniroyal-1206w4-series) | [General purpose](https://www.royalohm.com/assets/pdf/products/smd/1.pdf) (mfr) | 110,705 |+| `RC1206JR-07200KL` | Yageo | [RC120](/adom/yageo-rc120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RC_GROUP_51_ROHS_L) (mfr) | 32,604 |+| `AC1206JR-07200KL` | Yageo | [AC120](/adom/yageo-ac120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 5,675 |+| `CQ06W4J0204T5E` | Uniroyal | [CQ06](/adom/uniroyal-cq06-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2304140030_UNI-ROYAL-Uniroyal-Elec-CQ06W4J0204T5E_C2771307.pdf) (lcsc) | 2,700 |+| `RV1206JR-07200KL` | Yageo | [RV12](/adom/yageo-rv12-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RV_51_ROHS_L) (mfr) | 2,626 |
page.json+14−7
@@ -4,12 +4,12 @@   "type": "component",   "kind": "group",   "version": "0.1.0",-  "title": "200kΩ 1206 Resistors",-  "brief": "13 interchangeable 200kΩ 1206 resistors from 1 manufacturer(s).",-  "because": "CLASS group page: the shared home for 13 interchangeable 200kΩ 1206 resistors. Under the passives architecture (ray/passives-architecture) no MPN gets its own page — they are rows here, and this is the page a designer actually lands on when choosing a 200kΩ 1206 part. No existing page covers this class.",+  "title": "200k\u03a9 1206 Resistors",+  "brief": "19 interchangeable 200k\u03a9 1206 resistors.",+  "because": "CLASS group page: the shared home for 13 interchangeable 200k\u03a9 1206 resistors. Under the passives architecture (ray/passives-architecture) no MPN gets its own page \u2014 they are rows here, and this is the page a designer actually lands on when choosing a 200k\u03a9 1206 part. No existing page covers this class.",   "hero": {     "type": "billboard",-    "headline": "200kΩ 1206 Resistors",+    "headline": "200k\u03a9 1206 Resistors",     "subhead": "13 interchangeable parts, one footprint, one 3D model."   },   "component": {@@ -24,12 +24,16 @@     "distributor_links": {},     "group": {       "tier": "class",-      "member_count": 13,+      "member_count": 19,       "members": [+        "1206W4F2003T5E",+        "1206W4J0204T5E",         "AC1206FR-07200KL",         "AC1206JR-07200KL",         "AF1206FR-07200KL",         "AT1206BRD07200KL",+        "CQ06W4J0204T5E",+        "HV06W4F2003T5E",         "RC1206FR-07200KL",         "RC1206JR-07200KL",         "RT1206BRD07200KL",@@ -38,7 +42,9 @@         "RT1206DRE07200KL",         "RT1206FRE07200KL",         "RV1206FR-07200KL",-        "RV1206JR-07200KL"+        "RV1206JR-07200KL",+        "TC0625D2003T5J",+        "TC0650B2003T5J"       ]     }   },@@ -59,5 +65,6 @@     "member_count": 13   },   "created_at": "2026-09-10T15:47:12.517Z",-  "updated_at": "2026-09-10T15:47:13.021Z"+  "updated_at": "2026-09-10T15:47:13.021Z",+  "readme": "# 200k\u03a9 1206 Resistors\n\n**19 MPNs** from Uniroyal, Yageo. Parts within a section are interchangeable.\n\nCAD: [1206 resistor](/adom/1206-resistor-cad) \u2014 one footprint, symbol and 3D model shared by every part here.\n\n## \u00b10.1%, 250mW (4 MPNs)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `RT1206BRD07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 68,269 |\n| `TC0650B2003T5J` | Uniroyal | [TC06](/adom/uniroyal-tc06-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2208170930_UNI-ROYAL-Uniroyal-Elec-TC0650B2003T5J_C2989381.pdf) (lcsc) | 29,535 |\n| `AT1206BRD07200KL` | Yageo | [AT12](/adom/yageo-at12-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-AT_51_ROHS_L) (mfr) | 4,474 |\n| `RT1206BRE07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 5 |\n\n## \u00b10.5%, 250mW (3 MPNs)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `RT1206DRD07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 5,175 |\n| `RT1206DRE07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 40 |\n| `TC0625D2003T5J` | Uniroyal | [TC06](/adom/uniroyal-tc06-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2208170930_UNI-ROYAL-Uniroyal-Elec-TC0625D2003T5J_C2988899.pdf) (lcsc) | 15 |\n\n## \u00b11%, 250mW (7 MPNs)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `RC1206FR-07200KL` | Yageo | [RC120](/adom/yageo-rc120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RC_GROUP_51_ROHS_L) (mfr) | 177,506 |\n| `AC1206FR-07200KL` | Yageo | [AC120](/adom/yageo-ac120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 30,779 |\n| `RT1206FRE07200KL` | Yageo | [RT120](/adom/yageo-rt120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RT_1-TO-0-01_ROHS_L) (mfr) | 5,100 |\n| `1206W4F2003T5E` | Uniroyal | [1206W4](/adom/uniroyal-1206w4-series) | [General purpose](https://www.royalohm.com/assets/pdf/products/smd/1.pdf) (mfr) | 373 |\n| `RV1206FR-07200KL` | Yageo | [RV12](/adom/yageo-rv12-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RV_51_ROHS_L) (mfr) | 277 |\n| `HV06W4F2003T5E` | Uniroyal | [HV06](/adom/uniroyal-hv06-series) | [High voltage HV](https://www.royalohm.com/assets/pdf/products/smd/7.pdf) (mfr) | 228 |\n| `AF1206FR-07200KL` | Yageo | [AF120](/adom/yageo-af120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-AF_51_ROHS_L) (mfr) | 14 |\n\n## \u00b15%, 250mW (5 MPNs)\n\n| MPN | Manufacturer | Series | Datasheet | Stock |\n|---|---|---|---|---|\n| `1206W4J0204T5E` | Uniroyal | [1206W4](/adom/uniroyal-1206w4-series) | [General purpose](https://www.royalohm.com/assets/pdf/products/smd/1.pdf) (mfr) | 110,705 |\n| `RC1206JR-07200KL` | Yageo | [RC120](/adom/yageo-rc120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RC_GROUP_51_ROHS_L) (mfr) | 32,604 |\n| `AC1206JR-07200KL` | Yageo | [AC120](/adom/yageo-ac120-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L) (mfr) | 5,675 |\n| `CQ06W4J0204T5E` | Uniroyal | [CQ06](/adom/uniroyal-cq06-series) | [LCSC mirror](https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2304140030_UNI-ROYAL-Uniroyal-Elec-CQ06W4J0204T5E_C2771307.pdf) (lcsc) | 2,700 |\n| `RV1206JR-07200KL` | Yageo | [RV12](/adom/yageo-rv12-series) | [series](https://yageogroup.com/content/datasheet/asset/file/PYU-RV_51_ROHS_L) (mfr) | 2,626 |\n" }\ No newline at end of file