component
1206L005
Public Made by Adomby adom
LUTE Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
← Commit history
README.mdadded+38@@ -0,0 +1,38 @@+# 1206L005++**LUTE** · Resettable Fuses · 1206++1206L005 from LUTE, in a 1206. Pinout and pin descriptions extracted from the manufacturer datasheet by ds2sf; symbol, footprint, and 3D from KiCad-official CAD.++## Pinout++| Pin | Name | Type | Function |+|---|---|---|---|+| 1 | A | passive | Terminal 1 (left end-cap): one current-carrying terminal of the PPTC resettable fuse; I_hold = 0.05 A, I_trip = 0.15 A, V_max = 30 Vdc, I_max = 40 A, R_1max = 50.0 Ω at 25 °C; electrically symmetric with terminal 2. |+| 2 | B | passive | Terminal 2 (right end-cap): one current-carrying terminal of the PPTC resettable fuse; electrically identical and interchangeable with terminal 1; I_hold = 0.05 A, I_trip = 0.15 A, V_max = 30 Vdc, I_max = 40 A, R_1max = 50.0 Ω at 25 °C. |++## Key specifications++| Parameter | Value |+|---|---|+| Manufacturer | LUTE |+| Package | 1206 |+| Category | Circuit Protection |+| Pins | 2 |++## CAD (KiCad official)++- Symbol: `1206L005`+- Footprint: `Resistor_SMD:R_1206_3216Metric`+- 3D model: 1206 (KiCad packages3D, STEP)+- 3D model files: `1206l005-etched.step` / `1206l005-etched.glb` carry the MPN laser-etched on the die in a toggleable `Adom.LaserEtch` group (Fusion-ready); `1206l005.step` / `1206l005.glb` are the bare package body.++## Provenance++Data extracted from the manufacturer datasheet, not a distributor listing:++- **Datasheet:** [LUTE datasheet](https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8590908898721820672) (10 pp, sha256 `08e24bc3d6f2ec1a`, retrieved 2026-09-22, tier: lcsc)+- **Extractor:** parts-factory `2.0.0` / `extract_pins 0.2`, primary `claude-sonnet-4-6` (text+vision), consensus `claude-opus-4-7` (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.+- **CAD:** KiCad official libraries (CC-BY-SA 4.0).++[Datasheet PDF](docs/1206l005-datasheet.pdf)
page.jsonadded+108@@ -0,0 +1,108 @@+{+ "slug": "1206l005",+ "version": "0.1.0",+ "type": "component",+ "description": "LUTE Resettable Fuses, 1206. Datasheet-verified pinout, KiCad symbol/footprint/3D.",+ "tags": [+ "component",+ "circuit protection",+ "1206l005",+ "factory-2.0.0",+ "extractor-text"+ ],+ "dependencies": {},+ "hero": {+ "type": "image",+ "path": "docs/hero.png"+ },+ "files": [+ "page.json",+ "README.md",+ "1206l005.kicad_sym",+ "1206l005.kicad_mod",+ "1206l005.glb",+ "1206l005.step",+ "1206l005.lbr",+ "docs/hero.png",+ "docs/1206l005-datasheet.pdf",+ "viewers/symbol.html",+ "viewers/footprint.html"+ ],+ "component": {+ "mpn": "1206L005",+ "manufacturer": "LUTE",+ "package": "1206",+ "pin_count": 2,+ "category": "Circuit Protection",+ "subcategory": "Resettable Fuses",+ "datasheet": "https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8590908898721820672",+ "parts": {+ "symbol": "1206l005.kicad_sym",+ "footprint": "1206l005.kicad_mod",+ "model_3d": "1206l005-etched.glb",+ "model_3d_plain": "1206l005.glb",+ "model_3d_step": "1206l005-etched.step",+ "model_3d_step_plain": "1206l005.step",+ "lbr": "1206l005.lbr"+ },+ "distributor_links": {+ "lcsc": "C7542924"+ },+ "pins": [+ {+ "number": "1",+ "name": "A",+ "type": "passive",+ "description": "Terminal 1 (left end-cap): one current-carrying terminal of the PPTC resettable fuse; I_hold = 0.05 A, I_trip = 0.15 A, V_max = 30 Vdc, I_max = 40 A, R_1max = 50.0 Ω at 25 °C; electrically symmetric with terminal 2."+ },+ {+ "number": "2",+ "name": "B",+ "type": "passive",+ "description": "Terminal 2 (right end-cap): one current-carrying terminal of the PPTC resettable fuse; electrically identical and interchangeable with terminal 1; I_hold = 0.05 A, I_trip = 0.15 A, V_max = 30 Vdc, I_max = 40 A, R_1max = 50.0 Ω at 25 °C."+ }+ ],+ "provenance": {+ "extractor": "extract_pins 0.2",+ "factory_chain": {+ "factory": "2.0.0",+ "extractor": "extract_pins 0.2",+ "primary_model": "claude-sonnet-4-6",+ "primary_mode": "text+vision",+ "consensus_model": "claude-opus-4-7",+ "consensus": "agreed",+ "guards": "pin_guards 0.1: passed",+ "guard_notes": [+ "extractor flagged: The datasheet package drawing (page 3) labels only body-dimension references (A, B, C, D, E) and doe; MPN '1206L005' is a base family designator; the full orderable part number includes a voltage suffix",+ "vision extraction: provenance cannot be text-verified; needs consensus"+ ],+ "pages_sent": 10,+ "cost_usd": 0.3003,+ "at": "2026-09-22T00:29:11"+ },+ "datasheet": {+ "url": "https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8590908898721820672",+ "pages": 10,+ "sha256": "08e24bc3d6f2ec1a",+ "source_tier": "lcsc"+ },+ "cad": "KiCad official (CC-BY-SA 4.0)",+ "pins": {+ "total": 2,+ "described": 2,+ "cites_pages": true,+ "refuses_to_fabricate": true+ }+ },+ "viewers": {+ "symbol": "viewers/symbol.html",+ "footprint": "viewers/footprint.html"+ }+ },+ "visibility": "public",+ "org": "adom",+ "author": {+ "name": "Ray",+ "email": "[email protected]"+ }+}