← Commit history
page.json+407−30@@ -1,8 +1,11 @@ {+ "schema_version": 1,+ "type": "component", "slug": "1206l005-72nr",+ "title": "1206L005/72NR",+ "brief": "LUTE Resettable Fuses, 1206. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "version": "0.1.0",- "type": "component",- "description": "LUTE Resettable Fuses, 1206. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "license": "CC-BY-SA-4.0", "tags": [ "component", "circuit protection",@@ -10,26 +13,6 @@ "factory-2.0.0", "extractor-text" ],- "dependencies": {},- "hero": {- "type": "image",- "path": "docs/hero.png"- },- "files": [- "page.json",- "README.md",- "1206l005-72nr.kicad_sym",- "1206l005-72nr.kicad_mod",- "1206l005-72nr.glb",- "1206l005-72nr.step",- "1206l005-72nr.lbr",- "docs/hero.png",- "docs/1206l005-72nr-datasheet.pdf",- "viewers/symbol.html",- "viewers/footprint.html",- "1206l005-72nr-hero.glb",- "1206l005-72nr-hero.overlay.json"- ], "component": { "mpn": "1206L005/72NR", "manufacturer": "LUTE",@@ -125,8 +108,8 @@ 1.6, 0.55 ],- "zmin_mm": 0,- "centre_offset_mm": 0,+ "zmin_mm": 0.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "5e6dcbe286696143d35a8ea37d91eef4b54ff3d1bd7c2c2b4dedda83d3f8e203", "checked": "2026-11-20",@@ -139,7 +122,7 @@ "D": { "nom_mm": 3.3, "range_mm": [- 3,+ 3.0, 3.6 ] },@@ -168,9 +151,403 @@ } } },- "visibility": "private",- "org": "adom",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "1206",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "08e24bc3d6f2ec1ac3d8d83239c008e1965c5fdf142b18e07f3c037a9124316f",+ "rows": [+ {+ "name": "Minimum resistance, initial un-soldered state",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 3.6,+ "typ": null,+ "max": null,+ "conditions": "Initial (un-soldered) state; same for all 1206L005 voltage variants",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance after trip or reflow",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 50,+ "conditions": "25 °C, measured one hour after tripping or 260 °C reflow for 20 s",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.15,+ "typ": null,+ "max": null,+ "conditions": "25 °C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.05,+ "conditions": "25 °C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "At rated voltage (V max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "Variant 1206L005/30NR; at rated current (I max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 60,+ "conditions": "Variant 1206L005/60NR; at rated current (I max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 72,+ "conditions": "Variant 1206L005/72NR; at rated current (I max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip",+ "symbol": "T trip",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 1.5,+ "conditions": "At 0.25 A test current; 25 °C electrical characteristics",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.7,+ "max": null,+ "conditions": "Tripped state, 25 °C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, passive aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 1000 hours; typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, humidity aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 85% R.H., 168 hours; typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, thermal shock",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85 °C to -40 °C, 20 times; typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ambient operating conditions",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "Device in tripped state",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "Storage condition; 30%–60% RH",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Peak reflow temperature",+ "symbol": "Tp",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "Pb-free reflow; time within 5 °C of peak 20–40 s",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Time within 5 °C of peak reflow temperature",+ "symbol": "tp",+ "kind": "timing",+ "unit": "s",+ "min": 20,+ "typ": null,+ "max": 40,+ "conditions": "Pb-free reflow",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Hand soldering iron temperature",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 350,+ "conditions": "Soldering iron, weld position more than 1.5 mm from device",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Hand soldering contact time",+ "symbol": "",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 3,+ "conditions": "Contact time with solder joint",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Hold current vs ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.074,+ "conditions": "Ambient -40 °C (1206L005 family derating table)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current vs ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.066,+ "conditions": "Ambient -20 °C (1206L005 family derating table)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current vs ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.056,+ "conditions": "Ambient 0 °C (1206L005 family derating table)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current vs ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.05,+ "conditions": "Ambient 25 °C (1206L005 family derating table)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current vs ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.042,+ "conditions": "Ambient 40 °C (1206L005 family derating table)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current vs ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.037,+ "conditions": "Ambient 50 °C (1206L005 family derating table)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current vs ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.035,+ "conditions": "Ambient 60 °C (1206L005 family derating table)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current vs ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.03,+ "conditions": "Ambient 70 °C (1206L005 family derating table)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current vs ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.027,+ "conditions": "Ambient 85 °C (1206L005 family derating table)",+ "source_page": 6,+ "source": "datasheet"+ }+ ]+ }+ },+ "variants": [],+ "sections": [+ "hero",+ "viewers",+ "readme",+ "breadcrumbs",+ "info"+ ],+ "discovery_triggers": [+ "1206l005"+ ],+ "discovery_pitch": "1206L005 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.", "author": {- "name": "Ray"- }-}+ "name": "Ray",+ "email": "[email protected]"+ },+ "dependencies": {},+ "hero": {+ "type": "image",+ "path": "docs/hero.png"+ },+ "files": [+ "page.json",+ "README.md",+ "1206l005-72nr.kicad_sym",+ "1206l005-72nr.kicad_mod",+ "1206l005-72nr.glb",+ "1206l005-72nr.step",+ "1206l005-72nr.lbr",+ "docs/hero.png",+ "docs/1206l005-72nr-datasheet.pdf",+ "viewers/symbol.html",+ "viewers/footprint.html",+ "1206l005-72nr-hero.glb",+ "1206l005-72nr-hero.overlay.json"+ ]+}