← Commit history

0805l050-30ar: factory component page (tier=lcsc)

Ray ·654d09e3fb · ·parent 49de1ac
1 file changed +408−31
page.json+408−31
@@ -1,8 +1,11 @@ {+  "schema_version": 1,+  "type": "component",   "slug": "0805l050-30ar",+  "title": "0805L050/30AR",+  "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "version": "0.1.0",-  "type": "component",-  "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "license": "CC-BY-SA-4.0",   "tags": [     "component",     "circuit protection",@@ -10,26 +13,6 @@     "factory-2.0.0",     "extractor-text"   ],-  "dependencies": {},-  "hero": {-    "type": "image",-    "path": "docs/hero.png"-  },-  "files": [-    "page.json",-    "README.md",-    "0805l050-30ar.kicad_sym",-    "0805l050-30ar.kicad_mod",-    "0805l050-30ar.glb",-    "0805l050-30ar.step",-    "0805l050-30ar.lbr",-    "docs/hero.png",-    "docs/0805l050-30ar-datasheet.pdf",-    "viewers/symbol.html",-    "viewers/footprint.html",-    "0805l050-30ar-hero.glb",-    "0805l050-30ar-hero.overlay.json"-  ],   "component": {     "mpn": "0805L050/30AR",     "manufacturer": "LUTE",@@ -184,12 +167,12 @@         "origin": "footprint origin = pad-pattern centre",         "seat": "z = 0",         "extents_mm": [-          2,+          2.0,           1.25,           0.45         ],-        "zmin_mm": 0,-        "centre_offset_mm": 0,+        "zmin_mm": -0.0,+        "centre_offset_mm": 0.0,         "footprint_binding": "identity",         "sha256": "bd29ccc62530d3bcfbbe078f12aac2a99ac75d01c043a2723a4bd36540aac146",         "checked": "2026-11-20",@@ -202,7 +185,7 @@       "D": {         "nom_mm": 2.1,         "range_mm": [-          2,+          2.0,           2.2         ]       },@@ -231,9 +214,403 @@       }     }   },-  "visibility": "private",-  "org": "adom",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "0805",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "21e79b52aaa8e9ead8f6ff764d7bfbed9e664190b0e90d7b103a5dcf4f847522",+      "rows": [+        {+          "name": "Hold current, 25 °C still air (0805L050 family)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "0805L050/6XR, /12XR, /15XR, /16XR, /24XR, /30AR; maximum current passed without tripping, 25 °C still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Trip current, 25 °C still air",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 1,+          "typ": null,+          "max": null,+          "conditions": "0805L050 family; minimum current at which device trips, 25 °C still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/6XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "0805L050/6XR; rated voltage (at rated current I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/12XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 12,+          "conditions": "0805L050/12XR; rated voltage (at rated current I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/15XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 15,+          "conditions": "0805L050/15XR; rated voltage (at rated current I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/16XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 16,+          "conditions": "0805L050/16XR; rated voltage (at rated current I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/24XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 24,+          "conditions": "0805L050/24XR; rated voltage (at rated current I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/30AR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "0805L050/30AR; rated voltage (at rated current I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "0805L050 family; at rated voltage V max",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Power dissipated in tripped state, 6XR/12XR/15XR/16XR",+          "symbol": "P d typ.",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "0805L050/6XR, /12XR, /15XR, /16XR; typical, tripped state, 25 °C still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Power dissipated in tripped state, 24XR/30AR",+          "symbol": "P d typ.",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.8,+          "max": null,+          "conditions": "0805L050/24XR, /30AR; typical, tripped state, 25 °C still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum time to trip at assigned current",+          "symbol": "T trip",+          "kind": "timing",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "0805L050 family; at 8.00 A (time to trip, max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Minimum initial resistance (un-soldered)",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.1,+          "typ": null,+          "max": null,+          "conditions": "0805L050 family; initial state before soldering",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Hold current derated at -40 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.68,+          "conditions": "0805L050; ambient operating temperature -40 °C (derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derated at -20 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.62,+          "conditions": "0805L050; ambient operating temperature -20 °C (derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derated at 0 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.55,+          "conditions": "0805L050; ambient operating temperature 0 °C (derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derated at 25 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "0805L050; ambient operating temperature 25 °C (derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derated at 40 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.4,+          "conditions": "0805L050; ambient operating temperature 40 °C (derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derated at 50 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.37,+          "conditions": "0805L050; ambient operating temperature 50 °C (derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derated at 60 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.33,+          "conditions": "0805L050; ambient operating temperature 60 °C (derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derated at 70 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.29,+          "conditions": "0805L050; ambient operating temperature 70 °C (derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derated at 85 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.23,+          "conditions": "0805L050; ambient operating temperature 85 °C (derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after passive aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85 °C, 1000 hours; typical",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after humidity aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85 °C, 85 % R.H., 168 hours; typical",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after thermal shock",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85 °C to -40 °C, 20 times; typical",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "Ambient operating conditions",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "TSURF",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "Device in tripped state",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "TSTORE",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "Storage condition, sealed packaging",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Reflow peak temperature",+          "symbol": "TP",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "Lead-free reflow; time within 5 °C of peak 20-40 s",+          "source_page": 7,+          "source": "datasheet"+        }+      ]+    }+  },+  "variants": [],+  "sections": [+    "hero",+    "viewers",+    "readme",+    "breadcrumbs",+    "info"+  ],+  "discovery_triggers": [+    "0805l050"+  ],+  "discovery_pitch": "0805L050 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",   "author": {-    "name": "Ray"-  }-}\ No newline at end of file+    "name": "Ray",+    "email": "[email protected]"+  },+  "dependencies": {},+  "hero": {+    "type": "image",+    "path": "docs/hero.png"+  },+  "files": [+    "page.json",+    "README.md",+    "0805l050-30ar.kicad_sym",+    "0805l050-30ar.kicad_mod",+    "0805l050-30ar.glb",+    "0805l050-30ar.step",+    "0805l050-30ar.lbr",+    "docs/hero.png",+    "docs/0805l050-30ar-datasheet.pdf",+    "viewers/symbol.html",+    "viewers/footprint.html",+    "0805l050-30ar-hero.glb",+    "0805l050-30ar-hero.overlay.json"+  ]+}