← Commit history

Publish 0.1.1

Ray ·508882c474 · ·parent d948b64
2 files changed +353−7
package.json+348−2
@@ -1,6 +1,6 @@ {   "slug": "0805l050-12xr",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "tags": [@@ -210,5 +210,351 @@         "by": "factory/package_fit.py"       }     }-  }+  },+  "title": "0805L050/12XR",+  "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "0805",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "02a164fafb86ec79cb460f9ae36e1480d7ba2674247d8acdfa63655a28eafa35",+      "rows": [+        {+          "name": "Hold current (I hold)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "25°C still air; maximum current without tripping; all 0805L050/xXR codes",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Trip current (I trip)",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 1,+          "typ": null,+          "max": null,+          "conditions": "25°C still air; minimum current at which device trips; all 0805L050/xXR codes",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current (I max)",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "at rated voltage (V max); all 0805L050/xXR codes",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/6XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "0805L050/6XR; at rated current (I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/12XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 12,+          "conditions": "0805L050/12XR; at rated current (I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/15XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 15,+          "conditions": "0805L050/15XR; at rated current (I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage, 0805L050/24XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 24,+          "conditions": "0805L050/24XR; at rated current (I max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Initial minimum resistance (R min)",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.1,+          "typ": null,+          "max": null,+          "conditions": "initial (un-soldered) state; all 0805L050/xXR codes",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance after trip or reflow (R 1max)",+          "symbol": "R 1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 0.85,+          "conditions": "25°C, measured one hour after tripping or 260°C reflow for 20 s; all 0805L050/xXR codes",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum time to trip",+          "symbol": "T trip",+          "kind": "timing",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "at assigned current 8.00 A; Time to Trip (Max.)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Power dissipated when tripped, 0805L050/6XR, /12XR, /15XR",+          "symbol": "P d",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "typical, tripped state, 25°C still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Power dissipated when tripped, 0805L050/24XR",+          "symbol": "P d",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.8,+          "max": null,+          "conditions": "typical, tripped state, 25°C still air; 0805L050/24XR only",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at -40°C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.68,+          "conditions": "ambient operating temperature -40°C; 0805L050",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at -20°C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.62,+          "conditions": "ambient operating temperature -20°C; 0805L050",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 0°C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.55,+          "conditions": "ambient operating temperature 0°C; 0805L050",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 25°C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "ambient operating temperature 25°C; 0805L050",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 40°C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.4,+          "conditions": "ambient operating temperature 40°C; 0805L050",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 50°C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.37,+          "conditions": "ambient operating temperature 50°C; 0805L050",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 60°C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.33,+          "conditions": "ambient operating temperature 60°C; 0805L050",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 70°C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.29,+          "conditions": "ambient operating temperature 70°C; 0805L050",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 85°C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.23,+          "conditions": "ambient operating temperature 85°C; 0805L050",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after passive aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 1000 hours; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after humidity aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 85% R.H., 168 hours; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after thermal shock",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85°C to -40°C, 20 times; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "ambient operating conditions",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "device in tripped state",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "storage condition; 30%-60% RH",+          "source_page": 6,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "0805l050"+  ],+  "discovery_pitch": "0805L050 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+5−5
@@ -4,7 +4,7 @@   "slug": "0805l050-12xr",   "title": "0805L050/12XR",   "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -568,7 +568,7 @@     "0805l050-12xr-hero.glb",     "0805l050-12xr-hero.overlay.json"   ],-  "visibility": {-    "public": true-  }-}+  "visibility": "public",+  "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "org": "adom"+}\ No newline at end of file