← Commit history
package.json+372−2@@ -1,6 +1,6 @@ { "slug": "0805l035-24xr",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -220,5 +220,375 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0805L035/24XR",+ "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0805",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "02a164fafb86ec79cb460f9ae36e1480d7ba2674247d8acdfa63655a28eafa35",+ "rows": [+ {+ "name": "Hold current (maximum current without tripping)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.35,+ "conditions": "25°C still air; common to all 0805L035 voltage variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Trip current (minimum current that trips the device)",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.75,+ "typ": null,+ "max": null,+ "conditions": "25°C still air; common to all 0805L035 voltage variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current withstand",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "At rated voltage (Vmax)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip",+ "symbol": "T trip",+ "kind": "electrical",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "At 8.00 A (time-to-trip current column)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Minimum initial resistance",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.2,+ "typ": null,+ "max": null,+ "conditions": "Initial, un-soldered state",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance after trip or reflow",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 1.2,+ "conditions": "25°C, measured one hour after tripping or reflow soldering at 260°C for 20 s",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ambient operating conditions, 0805L Series",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "Device in tripped state",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "TSTORE",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "Storage condition, 30%-60% RH",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Storage relative humidity",+ "symbol": "RH",+ "kind": "recommended_operating",+ "unit": "%RH",+ "min": 30,+ "typ": null,+ "max": 60,+ "conditions": "Storage condition, 0°C-30°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Peak reflow temperature",+ "symbol": "Tp",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "Pb-free reflow; measured on package body topside",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time within 5°C of peak temperature",+ "symbol": "tp",+ "kind": "timing",+ "unit": "s",+ "min": 20,+ "typ": null,+ "max": 40,+ "conditions": "Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time above liquidus temperature TL (217°C)",+ "symbol": "tL",+ "kind": "timing",+ "unit": "s",+ "min": 60,+ "typ": null,+ "max": 150,+ "conditions": "Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Preheat time (Ts min 150°C to Ts max 200°C)",+ "symbol": "",+ "kind": "timing",+ "unit": "s",+ "min": 60,+ "typ": null,+ "max": 180,+ "conditions": "Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Average ramp-up rate (Ts max to Tp)",+ "symbol": "",+ "kind": "timing",+ "unit": "°C/s",+ "min": null,+ "typ": null,+ "max": 3,+ "conditions": "Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Ramp-down rate",+ "symbol": "",+ "kind": "timing",+ "unit": "°C/s",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time from 25°C to peak temperature",+ "symbol": "",+ "kind": "timing",+ "unit": "min",+ "min": null,+ "typ": null,+ "max": 8,+ "conditions": "Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, passive aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 1000 hours; printed as ±5% typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, humidity aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 85% R.H., 168 hours; printed as ±5% typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, thermal shock",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85°C to -40°C, 20 times; printed as ±33% typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.47,+ "conditions": "Ambient -40°C; 0805L035 derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.44,+ "conditions": "Ambient -20°C; 0805L035 derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.39,+ "conditions": "Ambient 0°C; 0805L035 derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.35,+ "conditions": "Ambient 25°C; 0805L035 derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.3,+ "conditions": "Ambient 40°C; 0805L035 derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.27,+ "conditions": "Ambient 50°C; 0805L035 derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.24,+ "conditions": "Ambient 60°C; 0805L035 derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.2,+ "conditions": "Ambient 70°C; 0805L035 derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.14,+ "conditions": "Ambient 85°C; 0805L035 derating table",+ "source_page": 5,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0805l035"+ ],+ "discovery_pitch": "0805L035 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0805l035-24xr", "title": "0805L035/24XR", "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -602,7 +602,7 @@ "0805l035-24xr-hero.glb", "0805l035-24xr-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}