← Commit history
package.json+396−2@@ -1,6 +1,6 @@ { "slug": "0805l035-12xr",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -220,5 +220,399 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0805L035/12XR",+ "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0805",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "02a164fafb86ec79cb460f9ae36e1480d7ba2674247d8acdfa63655a28eafa35",+ "rows": [+ {+ "name": "Hold current (maximum current without tripping, 25 C still air)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.35,+ "conditions": "0805L035 family, 25 C still air; device passes this current without tripping",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Trip current (minimum current to trip, 25 C still air)",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.75,+ "typ": null,+ "max": null,+ "conditions": "0805L035 family, 25 C still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current withstand at rated voltage",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "0805L035 family, at rated voltage V max",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L035/6XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "0805L035/6XR, at rated current I max",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L035/12XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 12,+ "conditions": "0805L035/12XR, at rated current I max",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L035/16XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 16,+ "conditions": "0805L035/16XR, at rated current I max",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L035/24XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 24,+ "conditions": "0805L035/24XR, at rated current I max",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L035/30XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "0805L035/30XR, at rated current I max",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Typical power dissipated in tripped state",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "0805L035/6XR, /12XR, /16XR; 25 C still air, tripped state",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Typical power dissipated in tripped state",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.8,+ "max": null,+ "conditions": "0805L035/24XR, /30XR; 25 C still air, tripped state",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip",+ "symbol": "T trip",+ "kind": "electrical",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "At 8.00 A assigned current; family-wide, all variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Minimum initial (un-soldered) resistance",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.2,+ "typ": null,+ "max": null,+ "conditions": "Initial, un-soldered state; all variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance after trip or reflow",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 1.2,+ "conditions": "25 C, measured one hour after tripping or reflow soldering at 260 C for 20 s; all variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum hold current at -40 C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.47,+ "conditions": "Ambient -40 C (temperature derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum hold current at -20 C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.44,+ "conditions": "Ambient -20 C (temperature derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum hold current at 0 C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.39,+ "conditions": "Ambient 0 C (temperature derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum hold current at 25 C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.35,+ "conditions": "Ambient 25 C (temperature derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum hold current at 40 C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.3,+ "conditions": "Ambient 40 C (temperature derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum hold current at 50 C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.27,+ "conditions": "Ambient 50 C (temperature derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum hold current at 60 C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.24,+ "conditions": "Ambient 60 C (temperature derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum hold current at 70 C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.2,+ "conditions": "Ambient 70 C (temperature derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum hold current at 85 C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.14,+ "conditions": "Ambient 85 C (temperature derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ambient operating conditions",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "Device in tripped state",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Passive aging resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 C, 1000 hours; typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Humidity aging resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 C, 85% R.H., 168 hours; typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Thermal shock resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85 C to -40 C, 20 cycles; typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "TSTORE",+ "kind": "thermal",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "Storage condition, 30%-60% RH",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Peak reflow temperature",+ "symbol": "Tp",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "Pb-free reflow; measured on package topside",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time within 5 C of peak temperature",+ "symbol": "tp",+ "kind": "timing",+ "unit": "s",+ "min": 20,+ "typ": null,+ "max": 40,+ "conditions": "Reflow, within 5 C of actual peak",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time from 25 C to peak temperature",+ "symbol": "",+ "kind": "timing",+ "unit": "min",+ "min": null,+ "typ": null,+ "max": 8,+ "conditions": "Reflow profile, 25 C to peak",+ "source_page": 6,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0805l035"+ ],+ "discovery_pitch": "0805L035 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0805l035-12xr", "title": "0805L035/12XR", "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -626,7 +626,7 @@ "0805l035-12xr-hero.glb", "0805l035-12xr-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}