← Commit history

Publish 0.1.1

Ray ·ae37421093 · ·parent 1f28700
2 files changed +305−7
package.json+300−2
@@ -1,6 +1,6 @@ {   "slug": "0805l010-9xr",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "tags": [@@ -240,5 +240,303 @@         "by": "factory/package_fit.py"       }     }-  }+  },+  "title": "0805L010/9XR",+  "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "0805",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "02a164fafb86ec79cb460f9ae36e1480d7ba2674247d8acdfa63655a28eafa35",+      "rows": [+        {+          "name": "Minimum resistance (initial, un-soldered state)",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.75,+          "typ": null,+          "max": null,+          "conditions": "Initial un-soldered state; family values for 0805L010/9XR to /48AR",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance after trip or reflow",+          "symbol": "R 1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "25 °C, measured one hour after tripping or 260 °C reflow for 20 s",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Trip current (minimum)",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 0.3,+          "typ": null,+          "max": null,+          "conditions": "25 °C still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Hold current (maximum without tripping)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "25 °C still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "At rated voltage (V max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum time to trip",+          "symbol": "T trip",+          "kind": "electrical",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 1.5,+          "conditions": "At assigned current 0.50 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Power dissipated in tripped state",+          "symbol": "P d",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "Tripped state, 25 °C still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at -40 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.14,+          "conditions": "Ambient -40 °C, 0805L010 row of derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at -20 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.12,+          "conditions": "Ambient -20 °C, 0805L010 row of derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 0 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.11,+          "conditions": "Ambient 0 °C, 0805L010 row of derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 25 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "Ambient 25 °C, 0805L010 row of derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 40 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.08,+          "conditions": "Ambient 40 °C, 0805L010 row of derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 50 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.07,+          "conditions": "Ambient 50 °C, 0805L010 row of derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 60 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.06,+          "conditions": "Ambient 60 °C, 0805L010 row of derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 70 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.05,+          "conditions": "Ambient 70 °C, 0805L010 row of derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current derating at 85 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.03,+          "conditions": "Ambient 85 °C, 0805L010 row of derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after passive aging",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85 °C, 1000 hours; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after humidity aging",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85 °C, 85% R.H., 168 hours; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after thermal shock",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85 °C to -40 °C, 20 times; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "Ambient operating conditions",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "Device in tripped state",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "TSTORE",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "Storage condition, 30%-60% RH",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Storage relative humidity",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "%RH",+          "min": 30,+          "typ": null,+          "max": 60,+          "conditions": "Storage condition, 0 °C to 30 °C",+          "source_page": 6,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "0805l010"+  ],+  "discovery_pitch": "0805L010 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+5−5
@@ -4,7 +4,7 @@   "slug": "0805l010-9xr",   "title": "0805L010/9XR",   "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -550,7 +550,7 @@     "0805l010-9xr-hero.glb",     "0805l010-9xr-hero.overlay.json"   ],-  "visibility": {-    "public": true-  }-}+  "visibility": "public",+  "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "org": "adom"+}\ No newline at end of file