← Commit history
package.json+192−2@@ -1,6 +1,6 @@ { "slug": "0805l010-15xr",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -240,5 +240,195 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0805L010/15XR",+ "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0805",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "02a164fafb86ec79cb460f9ae36e1480d7ba2674247d8acdfa63655a28eafa35",+ "rows": [+ {+ "name": "Hold current (maximum current without tripping, 25 °C still air)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "25 °C still air; same for all 0805L010 voltage variants (/9XR, /12XR, /15XR, /24XR, /33AR, /48AR)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Trip current (minimum current at which device trips, 25 °C still air)",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.3,+ "typ": null,+ "max": null,+ "conditions": "25 °C still air; same for all 0805L010 voltage variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current withstood at rated voltage",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "at rated voltage V max; same for all 0805L010 voltage variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "typical, tripped state at 25 °C still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip",+ "symbol": "T trip",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 1.5,+ "conditions": "at assigned current 0.50 A (5× hold current)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Minimum initial resistance (un-soldered)",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.75,+ "typ": null,+ "max": null,+ "conditions": "initial un-soldered state, 0805L010 variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance after trip or reflow",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "25 °C, measured one hour after tripping or reflow soldering at 260 °C for 20 s",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Resistance change after passive aging",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 1000 hours; printed ±5% typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Resistance change after humidity aging",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 85% R.H., 168 hours; printed ±5% typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Resistance change after thermal shock",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85 °C to -40 °C, 20 times; printed ±33% typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ambient operating conditions for 0805L series",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "device in tripped state",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature (packaged product)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "storage condition, 30%-60% RH",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Peak reflow temperature",+ "symbol": "Tp",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "Pb-free reflow profile peak temperature; time within 5 °C of peak 20-40 s",+ "source_page": 6,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0805l010"+ ],+ "discovery_pitch": "0805L010 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0805l010-15xr", "title": "0805L010/15XR", "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -442,7 +442,7 @@ "0805l010-15xr-hero.glb", "0805l010-15xr-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}