package.json+384−2@@ -1,6 +1,6 @@ { "slug": "0805l005-33xr",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -230,5 +230,387 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0805L005/33XR",+ "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0805",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "02a164fafb86ec79cb460f9ae36e1480d7ba2674247d8acdfa63655a28eafa35",+ "rows": [+ {+ "name": "Trip current (minimum current at which device trips)",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.15,+ "typ": null,+ "max": null,+ "conditions": "25°C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current device can withstand",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "at rated voltage (V max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Time to trip (max)",+ "symbol": "T trip",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 1.5,+ "conditions": "at assigned current 0.50 A",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Minimum resistance, initial (un-soldered) state",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 1.5,+ "typ": null,+ "max": null,+ "conditions": "initial un-soldered state",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance after tripping or reflow",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "25°C, measured one hour after tripping or reflow soldering at 260°C for 20 sec",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Passive aging resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 1000 hours (typical)",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Humidity aging resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 85% R.H., 168 hours (typical)",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Thermal shock resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85°C to -40°C, 20 times (typical)",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "ambient operating conditions",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "device in tripped state",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "storage condition, 30%-60%RH",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Storage relative humidity",+ "symbol": "",+ "kind": "thermal",+ "unit": "%RH",+ "min": 30,+ "typ": null,+ "max": 60,+ "conditions": "storage condition, 0°C to 30°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Preheat temperature (Ts)",+ "symbol": "Ts",+ "kind": "timing",+ "unit": "°C",+ "min": 150,+ "typ": null,+ "max": 200,+ "conditions": "pb-free reflow preheat, Ts(min) to Ts(max)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Preheat time",+ "symbol": "",+ "kind": "timing",+ "unit": "s",+ "min": 60,+ "typ": null,+ "max": 180,+ "conditions": "pb-free reflow, Ts(min) to Ts(max)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time above liquidus (TL 217°C)",+ "symbol": "tL",+ "kind": "timing",+ "unit": "s",+ "min": 60,+ "typ": null,+ "max": 150,+ "conditions": "pb-free reflow, above 217°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time within 5°C of actual peak temperature",+ "symbol": "tp",+ "kind": "timing",+ "unit": "s",+ "min": 20,+ "typ": null,+ "max": 40,+ "conditions": "pb-free reflow peak 260°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Average ramp-up rate (Ts(max) to Tp)",+ "symbol": "",+ "kind": "timing",+ "unit": "°C/s",+ "min": null,+ "typ": null,+ "max": 3,+ "conditions": "pb-free reflow, maximum",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Ramp-down rate",+ "symbol": "",+ "kind": "timing",+ "unit": "°C/s",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "pb-free reflow, maximum",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time from 25°C to peak temperature",+ "symbol": "",+ "kind": "timing",+ "unit": "min",+ "min": null,+ "typ": null,+ "max": 8,+ "conditions": "pb-free reflow, maximum",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current (maximum current passed without tripping)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.05,+ "max": null,+ "conditions": "25°C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state",+ "symbol": "Pd",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "tripped state, 25°C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at -40°C ambient",+ "symbol": "I hold",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.07,+ "max": null,+ "conditions": "ambient operating temperature -40°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current at -20°C ambient",+ "symbol": "I hold",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.06,+ "max": null,+ "conditions": "ambient operating temperature -20°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 0°C ambient",+ "symbol": "I hold",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.055,+ "max": null,+ "conditions": "ambient operating temperature 0°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 25°C ambient",+ "symbol": "I hold",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.05,+ "max": null,+ "conditions": "ambient operating temperature 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 40°C ambient",+ "symbol": "I hold",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.04,+ "max": null,+ "conditions": "ambient operating temperature 40°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 50°C ambient",+ "symbol": "I hold",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.035,+ "max": null,+ "conditions": "ambient operating temperature 50°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 60°C ambient",+ "symbol": "I hold",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.03,+ "max": null,+ "conditions": "ambient operating temperature 60°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 70°C ambient",+ "symbol": "I hold",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.025,+ "max": null,+ "conditions": "ambient operating temperature 70°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 85°C ambient",+ "symbol": "I hold",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.015,+ "max": null,+ "conditions": "ambient operating temperature 85°C",+ "source_page": 4,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0805l005"+ ],+ "discovery_pitch": "0805L005 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0805l005-33xr", "title": "0805L005/33XR", "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -624,7 +624,7 @@ "0805l005-33xr-hero.glb", "0805l005-33xr-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}