← Commit history

Publish 0.1.1

Ray ·126b08a29f · ·parent 67012ff
2 files changed +305−7
package.json+300−2
@@ -1,6 +1,6 @@ {   "slug": "0603l035-6xr",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "tags": [@@ -200,5 +200,303 @@         "by": "factory/package_fit.py"       }     }-  }+  },+  "title": "0603L035/6XR",+  "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "0603",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "9b801c861db9e4a6ca32810c794f03180f16926aedcf6b66bcc80a4bf471764c",+      "rows": [+        {+          "name": "Minimum trip current",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 0.75,+          "typ": null,+          "max": null,+          "conditions": "25℃ still air; minimum current at which device trips",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum hold current",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.35,+          "max": null,+          "conditions": "25℃ still air; maximum current device passes without tripping",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "At rated voltage (V max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Typical power dissipated in tripped state",+          "symbol": "P d",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "Tripped state, 25℃ still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum time to trip",+          "symbol": "T trip",+          "kind": "timing",+          "unit": "Sec",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "At 8.00 A trip current",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Minimum initial resistance",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.2,+          "typ": null,+          "max": null,+          "conditions": "Initial, un-soldered state",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance after trip or reflow",+          "symbol": "R 1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 1.4,+          "conditions": "25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 sec",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Passive aging resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85℃, 1000 hours; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Humidity aging resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85℃, 85% R.H., 168 hours; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Thermal shock resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85℃ to -40℃, 20 times; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "℃",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "Ambient operating conditions",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "℃",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "Device in tripped state",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "℃",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "Storage condition, 30%-60%RH",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Peak reflow temperature",+          "symbol": "Tp",+          "kind": "thermal",+          "unit": "℃",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "Pb-free recommended profile; time within 5℃ of peak 20-40 seconds",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Hold current at -40℃ ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.47,+          "max": null,+          "conditions": "Ambient -40℃ (temperature derating table, 0603L035)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at -20℃ ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.41,+          "max": null,+          "conditions": "Ambient -20℃ (temperature derating table, 0603L035)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 0℃ ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.38,+          "max": null,+          "conditions": "Ambient 0℃ (temperature derating table, 0603L035)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 25℃ ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.35,+          "max": null,+          "conditions": "Ambient 25℃ (temperature derating table, 0603L035)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 40℃ ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.29,+          "max": null,+          "conditions": "Ambient 40℃ (temperature derating table, 0603L035)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 50℃ ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.26,+          "max": null,+          "conditions": "Ambient 50℃ (temperature derating table, 0603L035)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 60℃ ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.24,+          "max": null,+          "conditions": "Ambient 60℃ (temperature derating table, 0603L035)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 70℃ ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.2,+          "max": null,+          "conditions": "Ambient 70℃ (temperature derating table, 0603L035)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 85℃ ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.14,+          "max": null,+          "conditions": "Ambient 85℃ (temperature derating table, 0603L035)",+          "source_page": 5,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "0603l035"+  ],+  "discovery_pitch": "0603L035 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+5−5
@@ -4,7 +4,7 @@   "slug": "0603l035-6xr",   "title": "0603L035/6XR",   "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -510,7 +510,7 @@     "0603l035-6xr-hero.glb",     "0603l035-6xr-hero.overlay.json"   ],-  "visibility": {-    "public": true-  }-}+  "visibility": "public",+  "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "org": "adom"+}\ No newline at end of file