← Commit history

Publish 0.1.1

Ray ·576319c2cd · ·parent 7bdc989
2 files changed +365−7
package.json+360−2
@@ -1,6 +1,6 @@ {   "slug": "0603l025-12xr",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "tags": [@@ -200,5 +200,363 @@         "by": "factory/package_fit.py"       }     }-  }+  },+  "title": "0603L025/12XR",+  "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "0603",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "9b801c861db9e4a6ca32810c794f03180f16926aedcf6b66bcc80a4bf471764c",+      "rows": [+        {+          "name": "Minimum trip current",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 0.55,+          "typ": null,+          "max": null,+          "conditions": "25℃ still air; minimum current at which the device trips",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Hold current",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.25,+          "conditions": "25℃ still air; maximum current device passes without tripping (printed as 0.25 with no min/max label)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "At rated voltage (V max)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Minimum initial resistance",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.5,+          "typ": null,+          "max": null,+          "conditions": "Initial (un-soldered) state",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance after trip or reflow",+          "symbol": "R 1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 3,+          "conditions": "25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 s",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum time to trip",+          "symbol": "",+          "kind": "timing",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 0.08,+          "conditions": "Time to trip (max.) at assigned current 8.00 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Passive aging resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85℃, 1000 hours; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Humidity aging resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85℃, 85% R.H., 168 hours; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Thermal shock resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85℃ to -40℃, 20 times; typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "Ambient operating conditions",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "Device in tripped state",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "Storage condition; 30%-60% RH",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Peak reflow temperature",+          "symbol": "Tp",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "Lead-free reflow peak temperature (Tp)",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Rated power in tripped state",+          "symbol": "P d",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "Typical power dissipated in tripped state, 25℃ still air",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage (variant 0603L025/6XR)",+          "symbol": "V max",+          "kind": "electrical",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "Variant 0603L025/6XR; maximum voltage without damage at rated current",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage (variant 0603L025/9XR)",+          "symbol": "V max",+          "kind": "electrical",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 9,+          "conditions": "Variant 0603L025/9XR; maximum voltage without damage at rated current",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage (variant 0603L025/12XR)",+          "symbol": "V max",+          "kind": "electrical",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 12,+          "conditions": "Variant 0603L025/12XR; maximum voltage without damage at rated current",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage (variant 0603L025/16XR)",+          "symbol": "V max",+          "kind": "electrical",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 16,+          "conditions": "Variant 0603L025/16XR; maximum voltage without damage at rated current",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage (variant 0603L025/24XR)",+          "symbol": "V max",+          "kind": "electrical",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 24,+          "conditions": "Variant 0603L025/24XR; maximum voltage without damage at rated current",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Hold current at ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.32,+          "conditions": "Ambient -40℃ (0603L025 family derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.29,+          "conditions": "Ambient -20℃ (0603L025 family derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.27,+          "conditions": "Ambient 0℃ (0603L025 family derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.25,+          "conditions": "Ambient 25℃ (0603L025 family derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.21,+          "conditions": "Ambient 40℃ (0603L025 family derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.18,+          "conditions": "Ambient 50℃ (0603L025 family derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.16,+          "conditions": "Ambient 60℃ (0603L025 family derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.14,+          "conditions": "Ambient 70℃ (0603L025 family derating table)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "Ambient 85℃ (0603L025 family derating table)",+          "source_page": 5,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "0603l025"+  ],+  "discovery_pitch": "0603L025 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+5−5
@@ -4,7 +4,7 @@   "slug": "0603l025-12xr",   "title": "0603L025/12XR",   "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -570,7 +570,7 @@     "0603l025-12xr-hero.glb",     "0603l025-12xr-hero.overlay.json"   ],-  "visibility": {-    "public": true-  }-}+  "visibility": "public",+  "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "org": "adom"+}\ No newline at end of file