← Commit history

Publish 0.1.1

Ray ·e1b454fcee · ·parent 3576479
2 files changed +425−7
package.json+420−2
@@ -1,6 +1,6 @@ {   "slug": "0603l020-12xr",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "tags": [@@ -195,5 +195,423 @@         "by": "factory/package_fit.py"       }     }-  }+  },+  "title": "0603L020/12XR",+  "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "0603",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "9b801c861db9e4a6ca32810c794f03180f16926aedcf6b66bcc80a4bf471764c",+      "rows": [+        {+          "name": "Hold current",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.2,+          "conditions": "25 °C still air; maximum current device passes without tripping (0603L020 voltage codes /6XR, /9XR, /12XR, /16XR)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Trip current",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 0.5,+          "typ": null,+          "max": null,+          "conditions": "25 °C still air; minimum current at which device trips",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "At rated voltage (V max); same value for all 0603L020 voltage codes",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Minimum initial resistance",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.55,+          "typ": null,+          "max": null,+          "conditions": "Initial (un-soldered) state",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance after trip or reflow",+          "symbol": "R 1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 3.5,+          "conditions": "25 °C, measured one hour after tripping or reflow soldering at 260 °C for 20 s",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum time to trip",+          "symbol": "T trip",+          "kind": "timing",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 0.6,+          "conditions": "At assigned current 1.00 A (5× I hold)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Hold current at -40 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.27,+          "conditions": "Ambient operating temperature -40 °C; 0603L020 derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at -20 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.25,+          "conditions": "Ambient operating temperature -20 °C; 0603L020 derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 0 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.23,+          "conditions": "Ambient operating temperature 0 °C; 0603L020 derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 25 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.2,+          "conditions": "Ambient operating temperature 25 °C; 0603L020 derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 40 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.17,+          "conditions": "Ambient operating temperature 40 °C; 0603L020 derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 50 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.14,+          "conditions": "Ambient operating temperature 50 °C; 0603L020 derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 60 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.12,+          "conditions": "Ambient operating temperature 60 °C; 0603L020 derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 70 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "Ambient operating temperature 70 °C; 0603L020 derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 85 °C ambient",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.07,+          "conditions": "Ambient operating temperature 85 °C; 0603L020 derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "Ambient operating conditions",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "Device in tripped state",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Passive aging resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85 °C, 1000 hours; printed as ±5% typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Humidity aging resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85 °C, 85% R.H., 168 hours; printed as ±5% typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Thermal shock resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85 °C to -40 °C, 20 times; printed as ±33% typical",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reflow peak temperature",+          "symbol": "Tp",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "Pb-free reflow peak temperature; time within 5 °C of peak 20–40 s",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Preheat temperature minimum",+          "symbol": "Ts(min)",+          "kind": "thermal",+          "unit": "°C",+          "min": 150,+          "typ": null,+          "max": null,+          "conditions": "Pb-free reflow preheat",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Preheat temperature maximum",+          "symbol": "Ts(max)",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 200,+          "conditions": "Pb-free reflow preheat",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Preheat time",+          "symbol": "",+          "kind": "timing",+          "unit": "s",+          "min": 60,+          "typ": null,+          "max": 180,+          "conditions": "Ts(min) to Ts(max) pb-free reflow preheat",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Time above liquidus temperature",+          "symbol": "tL",+          "kind": "timing",+          "unit": "s",+          "min": 60,+          "typ": null,+          "max": 150,+          "conditions": "Maintained above TL = 217 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Average ramp-up rate",+          "symbol": "",+          "kind": "timing",+          "unit": "°C/s",+          "min": null,+          "typ": null,+          "max": 3,+          "conditions": "Ts(max) to Tp, Pb-free reflow",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Ramp-down rate",+          "symbol": "",+          "kind": "timing",+          "unit": "°C/s",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "Pb-free reflow",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Time from 25 °C to peak temperature",+          "symbol": "",+          "kind": "timing",+          "unit": "minutes",+          "min": null,+          "typ": null,+          "max": 8,+          "conditions": "Pb-free reflow",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "TSTORE",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "Storage condition 30%–60% RH",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Maximum paste thickness",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "mm",+          "min": null,+          "typ": null,+          "max": 0.25,+          "conditions": "Recommended solder paste thickness for reflow",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Hand/iron soldering temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 350,+          "conditions": "If soldering iron used; weld position more than 1.5 mm from PTC",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Hand/iron soldering contact time",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 3,+          "conditions": "Contact time with solder joint if soldering iron used",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Power dissipation in tripped state",+          "symbol": "P d",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "Typical, tripped state at 25 °C still air",+          "source_page": 2,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "0603l020"+  ],+  "discovery_pitch": "0603L020 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+5−5
@@ -4,7 +4,7 @@   "slug": "0603l020-12xr",   "title": "0603L020/12XR",   "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -625,7 +625,7 @@     "0603l020-12xr-hero.glb",     "0603l020-12xr-hero.overlay.json"   ],-  "visibility": {-    "public": true-  }-}+  "visibility": "public",+  "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "org": "adom"+}\ No newline at end of file