← Commit history
page.json+407−30@@ -1,8 +1,11 @@ {+ "schema_version": 1,+ "type": "component", "slug": "0603l008-24xr",+ "title": "0603L008/24XR",+ "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "version": "0.1.0",- "type": "component",- "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "license": "CC-BY-SA-4.0", "tags": [ "component", "circuit protection",@@ -10,26 +13,6 @@ "factory-2.0.0", "extractor-text" ],- "dependencies": {},- "hero": {- "type": "image",- "path": "docs/hero.png"- },- "files": [- "page.json",- "README.md",- "0603l008-24xr.kicad_sym",- "0603l008-24xr.kicad_mod",- "0603l008-24xr.glb",- "0603l008-24xr.step",- "0603l008-24xr.lbr",- "docs/hero.png",- "docs/0603l008-24xr-datasheet.pdf",- "viewers/symbol.html",- "viewers/footprint.html",- "0603l008-24xr-hero.glb",- "0603l008-24xr-hero.overlay.json"- ], "component": { "mpn": "0603L008/24XR", "manufacturer": "LUTE",@@ -143,8 +126,8 @@ 0.8, 0.45 ],- "zmin_mm": 0,- "centre_offset_mm": 0,+ "zmin_mm": -0.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "2178c56deff687266eecad5e197b7ab2d230afae45def1320cff0ea839f46b49", "checked": "2026-11-20",@@ -172,7 +155,7 @@ "nom_mm": 0.7, "range_mm": [ 0.4,- 1+ 1.0 ] }, "source": "datasheet package drawing, every number found on its page (extract_pins --task dims)",@@ -186,9 +169,403 @@ } } },- "visibility": "private",- "org": "adom",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0603",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "9b801c861db9e4a6ca32810c794f03180f16926aedcf6b66bcc80a4bf471764c",+ "rows": [+ {+ "name": "Hold current (maximum current that does not trip)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.08,+ "conditions": "25 °C still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Trip current (minimum current that trips)",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.24,+ "typ": null,+ "max": null,+ "conditions": "25 °C still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 100,+ "conditions": "at rated voltage (Vmax)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Initial minimum resistance",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 3,+ "typ": null,+ "max": null,+ "conditions": "initial un-soldered state",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance after trip or reflow",+ "symbol": "R1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 14,+ "conditions": "25 °C, measured one hour after tripping or reflow soldering at 260 °C for 20 s",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip",+ "symbol": "",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 0.5,+ "conditions": "at 0.50 A assigned current, 25 °C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Hold current at -40 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.11,+ "conditions": "ambient -40 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at -20 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "ambient -20 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 0 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.09,+ "conditions": "ambient 0 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 25 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.08,+ "conditions": "ambient 25 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 40 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.06,+ "conditions": "ambient 40 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 50 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.05,+ "conditions": "ambient 50 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 60 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.04,+ "conditions": "ambient 60 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 70 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.03,+ "conditions": "ambient 70 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 85 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.02,+ "conditions": "ambient 85 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, passive aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 1000 hours; typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, humidity aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 85% R.H., 168 hours; typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, thermal shock",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85 °C to -40 °C, 20 times; typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "ambient operating conditions",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "storage condition",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Storage relative humidity",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "%RH",+ "min": 30,+ "typ": null,+ "max": 60,+ "conditions": "storage condition",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Preheat start temperature",+ "symbol": "Ts(min)",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 150,+ "typ": null,+ "max": 200,+ "conditions": "reflow preheat, Pb-free; preheat time 60–180 s",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Average ramp-up rate",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C/second",+ "min": null,+ "typ": null,+ "max": 3,+ "conditions": "Ts(max) to Tp, Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Ramp-down rate",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C/second",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time 25 °C to peak temperature",+ "symbol": "",+ "kind": "timing",+ "unit": "minutes",+ "min": null,+ "typ": null,+ "max": 8,+ "conditions": "Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Time within 5 °C of peak temperature",+ "symbol": "tp",+ "kind": "timing",+ "unit": "s",+ "min": 20,+ "typ": null,+ "max": 40,+ "conditions": "Pb-free reflow",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "device in tripped state",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Peak reflow temperature",+ "symbol": "Tp",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": 260,+ "max": null,+ "conditions": "Pb-free reflow, topside of package",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Typical power dissipated when tripped",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "tripped state, 25 °C still air",+ "source_page": 2,+ "source": "datasheet"+ }+ ]+ }+ },+ "variants": [],+ "sections": [+ "hero",+ "viewers",+ "readme",+ "breadcrumbs",+ "info"+ ],+ "discovery_triggers": [+ "0603l008"+ ],+ "discovery_pitch": "0603L008 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.", "author": {- "name": "Ray"- }-}+ "name": "Ray",+ "email": "[email protected]"+ },+ "dependencies": {},+ "hero": {+ "type": "image",+ "path": "docs/hero.png"+ },+ "files": [+ "page.json",+ "README.md",+ "0603l008-24xr.kicad_sym",+ "0603l008-24xr.kicad_mod",+ "0603l008-24xr.glb",+ "0603l008-24xr.step",+ "0603l008-24xr.lbr",+ "docs/hero.png",+ "docs/0603l008-24xr-datasheet.pdf",+ "viewers/symbol.html",+ "viewers/footprint.html",+ "0603l008-24xr-hero.glb",+ "0603l008-24xr-hero.overlay.json"+ ]+}