← Commit history

Publish 0.1.1

Ray ·13d4a7c808 · ·parent bec752f
2 files changed +389−7
package.json+384−2
@@ -1,6 +1,6 @@ {   "slug": "0603l005-9ar",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "tags": [@@ -230,5 +230,387 @@         "by": "factory/package_fit.py"       }     }-  }+  },+  "title": "0603L005/9AR",+  "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "0603",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "9b801c861db9e4a6ca32810c794f03180f16926aedcf6b66bcc80a4bf471764c",+      "rows": [+        {+          "name": "Hold current",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.05,+          "conditions": "25 C still air; 0603L005 family",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Trip current",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 0.15,+          "typ": null,+          "max": null,+          "conditions": "25 C still air; 0603L005 family",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "at rated voltage V max; 0603L005 family",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Minimum initial resistance",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "ohm",+          "min": 3.8,+          "typ": null,+          "max": null,+          "conditions": "initial un-soldered state; 0603L005 family",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance after trip or reflow",+          "symbol": "R1max",+          "kind": "electrical",+          "unit": "ohm",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "25 C, measured one hour after tripping or reflow soldering at 260 C for 20 s; 0603L005 family",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum time to trip",+          "symbol": "T trip",+          "kind": "timing",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "at assigned trip test current 0.25 A; 0603L005 family",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rated voltage V max, variant /6AR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "maximum voltage at rated current I max; variant 0603L005/6AR",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rated voltage V max, variant /9AR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 9,+          "conditions": "maximum voltage at rated current I max; variant 0603L005/9AR",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rated voltage V max, variant /15AR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 15,+          "conditions": "maximum voltage at rated current I max; variant 0603L005/15AR",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rated voltage V max, variant /24AR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 24,+          "conditions": "maximum voltage at rated current I max; variant 0603L005/24AR",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rated voltage V max, variant /33AR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 33,+          "conditions": "maximum voltage at rated current I max; variant 0603L005/33AR",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rated voltage V max, variant /48AR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 48,+          "conditions": "maximum voltage at rated current I max; variant 0603L005/48AR",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Power dissipated in tripped state",+          "symbol": "Pd",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "typical, tripped state at 25 C still air; 0603L005 family",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Hold current at -40 C ambient (derating)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.065,+          "conditions": "ambient -40 C; 0603L005 temperature derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at -20 C ambient (derating)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.06,+          "conditions": "ambient -20 C; 0603L005 temperature derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 0 C ambient (derating)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.055,+          "conditions": "ambient 0 C; 0603L005 temperature derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 25 C ambient (derating)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.05,+          "conditions": "ambient 25 C; 0603L005 temperature derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 40 C ambient (derating)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.04,+          "conditions": "ambient 40 C; 0603L005 temperature derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 50 C ambient (derating)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.035,+          "conditions": "ambient 50 C; 0603L005 temperature derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 60 C ambient (derating)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.031,+          "conditions": "ambient 60 C; 0603L005 temperature derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 70 C ambient (derating)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.025,+          "conditions": "ambient 70 C; 0603L005 temperature derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Hold current at 85 C ambient (derating)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.015,+          "conditions": "ambient 85 C; 0603L005 temperature derating table",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after passive aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "typical; +85 C, 1000 hours",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after humidity aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "typical; +85 C, 85% R.H., 168 hours",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Resistance change after thermal shock",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "typical; +85 C to -40 C, 20 times",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "ambient operating conditions",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "device in tripped (protected) state",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "TSTORE",+          "kind": "thermal",+          "unit": "C",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "storage at 30%-60% RH",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Reflow peak temperature",+          "symbol": "",+          "kind": "thermal",+          "unit": "C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "lead-free reflow peak (Tp); 20 s at 260 C reflow per resistance note",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Time within 5 C of peak temperature",+          "symbol": "",+          "kind": "timing",+          "unit": "s",+          "min": 20,+          "typ": null,+          "max": 40,+          "conditions": "time within 5 C of actual peak temperature during reflow",+          "source_page": 6,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "0603l005"+  ],+  "discovery_pitch": "0603L005 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+5−5
@@ -4,7 +4,7 @@   "slug": "0603l005-9ar",   "title": "0603L005/9AR",   "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -624,7 +624,7 @@     "0603l005-9ar-hero.glb",     "0603l005-9ar-hero.overlay.json"   ],-  "visibility": {-    "public": true-  }-}+  "visibility": "public",+  "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "org": "adom"+}\ No newline at end of file