package.json+204−2@@ -1,6 +1,6 @@ { "slug": "0603l003-30ar",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -195,5 +195,207 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0603L003/30AR",+ "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0603",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "3fe658b433088da1cd8b1224a6f965bbe4b47984ea544cae28f0b20329a40876",+ "rows": [+ {+ "name": "Hold current",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.03,+ "max": null,+ "conditions": "25°C still air; maximum current without tripping; same for /30AR and /60AR",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.09,+ "typ": null,+ "max": null,+ "conditions": "25°C still air; minimum current at which device trips; same for /30AR and /60AR",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage (variant 30AR)",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "0603L003/30AR; at rated current I max",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage (variant 60AR)",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 60,+ "conditions": "0603L003/60AR; at rated current I max",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "at rated voltage V max; same for /30AR and /60AR",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "typical; tripped state, 25°C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Time to trip (max)",+ "symbol": "T trip",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "at 0.20 A; 25°C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Minimum resistance, initial",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 6,+ "typ": null,+ "max": null,+ "conditions": "initial un-soldered state",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance after trip or reflow",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 50,+ "conditions": "25°C, measured one hour after tripping or after reflow soldering at 260°C for 20 s",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Passive aging resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 1000 hours; typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Humidity aging resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 85% R.H., 168 hours; typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Thermal shock resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85°C to -40°C, 20 times; typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "ambient operating conditions",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "TSTORE",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "storage condition; 30%-60% RH",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "device in tripped (protected) state",+ "source_page": 4,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0603l003"+ ],+ "discovery_pitch": "0603L003 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0603l003-30ar", "title": "0603L003/30AR", "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -409,7 +409,7 @@ "0603l003-30ar-hero.glb", "0603l003-30ar-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}