← Commit history
package.json+300−2@@ -1,6 +1,6 @@ { "slug": "0603l002-30ar",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -195,5 +195,303 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0603L002/30AR",+ "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0603",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "9429e6333a83aaaed8ac16419952d5db1e20660208bdba866c4611e11cf72816",+ "rows": [+ {+ "name": "R min (initial, un-soldered resistance)",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 12,+ "typ": null,+ "max": null,+ "conditions": "Minimum resistance in initial (un-soldered) state; same for /30AR and /60AR",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "R 1max (resistance after trip or reflow)",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 70,+ "conditions": "25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 sec; same for /30AR and /60AR",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "I trip (trip current)",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.06,+ "typ": null,+ "max": null,+ "conditions": "25℃ still air; minimum current at which the device trips; same for /30AR and /60AR",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "V max (0603L002/30AR)",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "0603L002/30AR; maximum voltage device withstands without damage at rated current (I max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "V max (0603L002/60AR)",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 60,+ "conditions": "0603L002/60AR; maximum voltage device withstands without damage at rated current (I max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "I max",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "Maximum fault current withstood without damage at rated voltage (V max); same for /30AR and /60AR",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Time to trip (max) at 0.20 A",+ "symbol": "T trip",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "Maximum time to trip at 0.20 A test current (table columns Current (A) 0.20, Time (Sec) 1.00)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, passive aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 1000 hours; printed as ±5% typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, humidity aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 85% R.H., 168 hours; printed as ±5% typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, thermal shock",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85°C to -40°C, 20 times; printed as ±33% typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "℃",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ambient operating conditions",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "℃",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "Device in tripped state",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature (recommended)",+ "symbol": "TSTORE",+ "kind": "recommended_operating",+ "unit": "℃",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "Storage condition; 30%-60%RH",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "I hold (hold current)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.02,+ "max": null,+ "conditions": "25℃ still air; maximum current device passes without tripping",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "P d (power dissipated when tripped)",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "Tripped state at 25℃ still air (typical)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "I hold at ambient -40℃ (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.031,+ "max": null,+ "conditions": "Ambient -40℃, from temperature derating table for 0603L002",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "I hold at ambient -20℃ (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.027,+ "max": null,+ "conditions": "Ambient -20℃, from temperature derating table for 0603L002",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "I hold at ambient 0℃ (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.024,+ "max": null,+ "conditions": "Ambient 0℃, from temperature derating table for 0603L002",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "I hold at ambient 40℃ (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.016,+ "max": null,+ "conditions": "Ambient 40℃, from temperature derating table for 0603L002",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "I hold at ambient 50℃ (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.014,+ "max": null,+ "conditions": "Ambient 50℃, from temperature derating table for 0603L002",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "I hold at ambient 60℃ (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.012,+ "max": null,+ "conditions": "Ambient 60℃, from temperature derating table for 0603L002",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "I hold at ambient 70℃ (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.011,+ "max": null,+ "conditions": "Ambient 70℃, from temperature derating table for 0603L002",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "I hold at ambient 85℃ (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.007,+ "max": null,+ "conditions": "Ambient 85℃, from temperature derating table for 0603L002",+ "source_page": 6,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0603l002"+ ],+ "discovery_pitch": "0603L002 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0603l002-30ar", "title": "0603L002/30AR", "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -505,7 +505,7 @@ "0603l002-30ar-hero.glb", "0603l002-30ar-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}